6
typical 1C as a maximum current for Li-Ion cells.
1C means that charge current for a 1Ah battery
should be max 1A. Thus the typical minimum
capacity recommendation is 1Ah for a 1A charger.
For max battery capacity we have used C/40 for
chargers with timer (and/or uC) and 100 times
current detection levels for chargers using only
this termination method. For a 1A charger with
0.1A current detection level the max capacity
recommended will be 100 x 0.1A = 10Ah. Again
this is just typical recommendations. Please read
recommendations and datasheets from battery
manufacturer.
How to connect exchangeable AC-plugs
The following exchangeable AC plugs are available:
”EURO”
250V 2.5A (EN50075/IEC83 C5 II)
”US”
125V 2.5A (NEMA 1-15 / CSA-C22.2 No.42)
”UK”
250V 13A (BS 1363)
”AUS”
250V 10A (AS/NZS 3112)
Mains Cord Set is available on request if you wish your product to be ”DeskTop”
How to connect exchangeable DC-output plugs
1. To connect for desired polarity, both plug
ends are clearly marked.
2. When connected, the female plug is also
marked on each side to identify plug
polarity.
3. Shows the center polarity of the plug.
3
12
3
1
2