8/8/2014
VECTOR COMPACT
file:///C:/Users/E139344/Documents/Miscellaneous/Manuals,%20etc/Rinker/VECTOR%20COMPACT.htm
24/37
Attached to solid level platform with hold down clips provided
Condensate drain routed aft and down hill to a sealed sump (not bilge)
Blower rotated toward supply air grille
Electrical
All butt connections on pump wire tightly crimped and heat shrunk
AC power source installed and grounded/bonded in accordance with ABYC standards
Control wires connected to terminal strip with fork terminals
Circuit breakers sized according to specifications on the data plate label
Passport II display cable is connected at both ends
Pump relay panel, if used, must have its own circuit breaker sized for the pump (20 amps max)
Grilles and Ducting
Supply air grille mounted as high as possible
Return air grille mounted as low and as close to the a/c unit as possible
Return air grille mounted away from bilge vapors or exhaust fumes
Ducting is pulled taut, straight, smooth and properly connected with no excess
OPERATIONS
QUICK START OPERATIONS CHECKLIST
Ensure sea water intake ball valve (sea cock) is open.
Turn on the A/C circuit breaker. If the sea water pump has its own circuit breaker, turn that on.
Turn the system on.
Set the desired cabin temperature (set point).
Check for a steady solid stream of water from the overboard discharge.
Verify that there is steady airflow out of the supply air grille.
If the unit does not appear to be operating properly, refer to troubleshooting guidelines.
Note: Do not turn the unit off and immediately turn it back on. Allow at least 30 seconds for refrigerant pressure
equalization.
PASSPORT II CONTROL