CIRCULATION MODE (FAN ONLY):
With the system off, press and hold the FAN button until the desired fan speed is indicated by the numbers "1" (slow) through
"6" (fast). To turn the fan off press and hold the FAN button until the number "0" appears in the display window.
PROGRAMMING THE PASSPORT II
The program mode is used to adjust operating parameters to tailor the system for efficient operation and to allow for user
flexibility. Installation variables such as ducting, sensor location and system layout effect the operation of the overall system.
Custom programming allows the system to operate as efficiently as possible in any given installation.
NOTE: When using the POWER button in conjunction with another button, i.e. pressing the POWER and DOWN
buttons simultaneously to unlock the program mode, try to press the other button a split second before the power
button so as not to turn the unit on or off accidentally.
TO ENTER PROGRAM MODE: With the system off, press and hold the POWER button for five seconds until the letter
"U" appears in the display window. Release the button and the first parameter setting appears followed by "U 1".
TO UNLOCK PROGRAM MODE: After entering the program mode, simultaneously press and release the POWER and
DOWN buttons.
TO SELECT PROGRAM PARAMETER: Press and hold the FAN button to scroll through the parameters indicated by the
program number. Programs are described in the following table.
TO CHANGE THE PROGRAM PARAMETER: Use the UP and DOWN buttons to select data or set the desired limits.
The range of parameter settings is listed in the following table.
TO RESET DEFAULT SETTINGS: With the system off, press and hold the POWER button for ten seconds until the
software version number (A##) appears in the display window.
TO LOCK NEW DEFAULT SETTINGS: Once the desired program changes have been made and before exiting the
program mode, simultaneously press and release the UP and DOWN buttons. Locking new defaults will render the factory
defaults obsolete. Make note of the new defaults in the following chart for future reference.
TO EXIT PROGRAM MODE: Press the POWER button or press no button for sixty seconds. The software version
number is displayed for one second prior to exiting the program mode.
PROGRAMMABLE PARAMETERS:
Program
Number
Description
Default
Setting
New**
Default
Range