Shiver
SC
22
23
9
22
8
17-46
25
18
FIG. 6
Push the stanchion tubes into the sliders and
remove the upper washer
(25)
, the preload
sleeve
(17)
or
(46)
and the spring
(18)
.
Remove all parts and let all the oil drain into
the fork leg. By following this procedure,
there is no need to check the oil level.
Make all necessary changes.
FIG. 4
Unscrew the caps
(22)
with a 21 mm
socket wrench.
Remove the caps complete with O-ring
(23)
from the outer sliders.
FIG. 5
Push down the outer sliders onto the stan-
chion tubes.
Lock the check nut
(8)
and remove the cap
(22)
from hydraulic cartridge top
(9)
.