Shiver
DC
10
32
9
24
29
23
1
2
FIG. 4
Push down the outer slider onto the stan-
chion tube.
Lock the check nut
(9)
and remove the cap
(32)
from hydraulic cartridge top
(10)
.
FIG. 5
Push the stanchion tube into the slider and
remove the upper washer
(29)
, the preload
sleeve
(23)
and the spring
(24)
.
Remove all parts and let all the oil drain into
the fork leg. By following this procedure,
there is no need to check the oil level.
Make all necessary changes.
REMOVING HYDRAULIC
CARTRIDGE
FIG. 6
Let all the oil drain out.
WARNING:
dispose of exhausted
oil in compliance with current laws.
To change the fork leg oil follow the proce-
dure as described at section FILLING WITH
OIL.
Remove the stanchion tube from the slider.
Turn the stanchion tube upside-down and
unscrew the foot nut
(1)
complete with O-
ring
(2)
using a
15 mm
socket wrench.