Connect battery to condenser cooling fan motor (1) as shown in fig-
ure, then check that the condenser cooling fan motor operates
smoothly.
Reference current : approx. 6 – 9 A at 12 V
REMOVAL AND INSTALLATION
Refer to A/C CONDENSER ASSEMBLY in this section.
RECEIVER/DRYER
Inspection
Use a leak tester to check for gas leakage, sight glass, fusible plug
and fittings.
Removal
1) Recover refrigerant by using recovery and recycling equipment
(1). Be sure to follow the instruction manual for the equipment.
The amount of compressor oil removed must be measured and
the same amount added to the system.
2) Disconnect condenser outlet pipe (1) and receiver/dryer outlet
pipe (2) from receiver/dryer (3).
3) Remove receiver dryer (3) from its holder by removing mount-
ing bolt (4).
NOTE:
As soon as above hose and pipe are disconnected, cap
opened fittings so that moisture and may not enter receiv-
er/dryer.
1B-26
AIR CONDITIONING (OPTIONAL)
SH410
Содержание Zen
Страница 2: ......
Страница 233: ...6E1 6 ENGINE AND EMISSION CONTROL SYSTEM SH410 ...
Страница 358: ... SH410 Prepared by Overseas Service Department 1st Ed January 2000 Printing January 2000 356 ...