Brush
Exposed Brush Length
Check each brush for wear by measuring its length as shown. If
brush is found worn down to service limit, replace brush. Refer to
“Replace Brush” in this section.
Exposed brush length “a”
Standard : 10.5 mm (0.413 in.)
Limit
: 1.5 mm (0.059 in.)
Rectifier
Positive Rectifier
1) Using an ohmmeter, connect one tester probe to the B terminal
(1) and the other to each rectifier terminal (2).
2) Reverse the polarity of tester probes and repeat step 1).
3) Check that one shows continuity and the other shows no conti-
nuity.
If there is continuity, replace rectifier.
Negative Rectifier
1) Using ohmmeter, connect one tester probe to each negative ter-
minal (1) and the other to each rectifier terminal (2).
2) Reverse the polarity of tester probes and repeat step 1).
3) Check that one shows continuity and the other shows no conti-
nuity.
If there is continuity, replace rectifier.
6H-18
CHARGING SYSTEM
SH410