Continuity Test
Overload Protection: 500v DC or AC rms
DC Volts
Overload protection: 1000VDC / 750V AC RMS
AC Volts
(Average sensing RMS indicating)
Frequency Response: 50Hz to 500Hz
Overload protection: 1000VDC or 750V AC RMS
AC Current
(Average sensing RMS indicating)
Overload Protection: 1200A for 60 seconds Maximum
Resistance
Overload Protection: 500v DC or AC RMS
Audible Threshold
Open Circuit Volts
Response Time
Less than 75
Ω
3.0Vdc typical
~500msec
~
Range
Resolution
Accuracy
Input Impedance
1000V
1V
±(0.5% rdg +1d)
10M
Ω
Range
Resolution
Accuracy
Input Impedance
750V
1V
±(1.5% rdg +4d)
4.5M
Ω
Range
Resolution
Accuracy
200A
1000A
100mA
1A
0-600A±(1.5% rdg+5d)50-60Hz
>600A±(2.0% rdg+5d)50-60Hz
0-600A±(3.0%rdg+5d)61-400Hz
>600A±(3.5%rdg+5d)61-400Hz
Range
200
Ω
20k
Ω
20M
Ω
2000M
Ω
0.1
Ω
10
Ω
10k
Ω
1000k
Ω
±(1.2% rdg+4d)
±(1.0% rdg+3d)
±(2.0% rdg+5d)
±(5% rdg+10d)
3.0Vdc
0.3Vdc
0.3Vdc
3.0Vdc
Resolution
Accuracy
Open Circuit Volts
G
16th Edition Testers
G
All-in-one’s
G
Calibration Equipment
G
Continuity Testers
G
Electrician’s Kits
G
Full Calibration & Repair Service
G
Fuse Finders
G
Digital Clamp Meters
G
Digital Multimeters
G
Microwave Leakage Detectors
G
Motor Maintenance Equipment
G
Non-trip Loop Testers
G
PAT Testers & accessories
G
Phase Rotation Units
G
Proving Units
G
Socket Testers
G
Thermometers & Probes
G
Test Leads
G
Voltage Indicators
G
Specialist Metrohm Testers (4 & 5kV)
G
Specialist Drummond Testers
Other products from Martindale:
Martindale Electric Company Limited
Metrohm House, Penfold Trading Estate, Imperial Way, Watford, WD24 4YY, UK.
Tel: +44(0)1923 441717 Fax: +44 (0)1923 446900
E-mail: [email protected]
Website: www.martindale-electric.co.uk
© Martindale Electric Company Ltd. 1997 - 2006
Registered in England No. 3387451. Rev 4