background image

Basic service

17

4 Grasp the old lamp by the reflector and slide it carefully out of the lamp 

holder. 

5 Pull the socket off the lamp. Do not pull the wires. 
6 Push the socket fully onto the pins of the new lamp.
7 Clean the glass bulb and reflector with a cloth, particularly if your fingers 

touched the glass. A clean, lint-free cloth wetted with alcohol is best.

8 Gently push the lamp into the holder until it snaps into place.
9 Close the fixture cover and tighten the thumb screw.

 

M A I N S   F U S E

The Mania DC2 uses a time-delay fuse for protection against current 
overload. An indication that the fuse may have blown is that when power 
is applied and the lamp is switched on, no light is produced.

If the fuse blows repeatedly, there is a fault with the unit that requires 
service by a Martin technician. 

Never bypass the fuse or replace it with one of another size or rating.

R e p l a c i n g   t h e   m a i n   f u s e

1 Unplug the mains cable from the input socket and allow the fixture to cool 

for 5 minutes.

2 Pry open the fuse holder (located next to the mains power connector) with 

a flat-head screwdriver and remove the fuse.

3 Replace the fuse with one of the same type. The fuse rating is listed on 

the serial number label and in “Specifications” on page 19.

4 Replace the fuse holder.

Содержание Mania DC2

Страница 1: ...Mania DC2 user manual ...

Страница 2: ...2 142 290 250 Ø13 2003 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in China P N 35000138 Rev B ...

Страница 3: ...6 Mania DC2 overview 6 Installation 7 AC power 7 Overhead mounting 9 Changing effect orientation 10 Operation 12 Controls 12 Focusing the Mania DC2 13 Basic service 14 Cleaning 14 Lamp maintenance 15 Mains fuse 17 Troubleshooting 18 Specifications 19 ...

Страница 4: ...xture safely please contact a Martin distributor for assistance Refer any service operation not described in this manual to a qualified technician Do not modify the fixture or install other than genuine Martin accessories and upgrade kits Refer servicing to qualified personnel Maximum ambient temperature Ta 40 C 104 F See serial label for replacement fuse size and lamp type Suitable for mounting o...

Страница 5: ... The exterior of the fixture can become hot Allow to cool for at least 5 minutes before handling or opening Surface temperature under steady state condition 60 C 140 F Minimum distance to flammable material 0 3 m 1 ft Minimum distance to illuminated surface 1 0 m 3 3 ft Never attempt to bypass the thermostatic switch or fuses Always replace defective fuses with ones of the specified type and ratin...

Страница 6: ...a safety cable Block access below the work area whenever installing or removing the fixture UNPACKING The packing material is carefully designed to protect the fixture during shipment always use it to transport the fixture The Mania DC2 comes with the following 3 wire IEC power cable User manual MANIA DC2 OVERVIEW Effect speed Fuse holder Thumb screw cover lock Power on switch Swivel locks Mountin...

Страница 7: ... the external power cord of this luminaire is damaged it shall be replaced by a special cord exclusively available from your Martin dealer Configuring for local mains power The Mania DC2 has a switch selectable power supply that can operate in the following voltage ranges at 50 60 Hz 115 120 volts setting 115 220 240 volts setting 230 Warning Do not operate the fixture on a power supply that falls...

Страница 8: ... cap that fits your power distribution cable or outlet Consult a qualified electrician if you have any doubts about proper installation Following the cord cap manufacturer s instructions connect the appropriate wires to ground earth live and neutral The following table below shows some common wire identification schemes Applying power 1 Connect the mains power cable to the fixture at the 3 prong I...

Страница 9: ... for the fixture s weight Bolt the clamp securely to the mounting bracket on the fixture with a grade 8 8 minimum M12 bolt and lock nut or as recommended by the clamp manufacturer through the clamp hole in the mounting bracket 3 If permanently installing the fixture verify that the hardware not included and mounting surface can bear at least 10 times the fixture s weight 4 Working from a stable pl...

Страница 10: ...ters 4 in CHANGING EFF ECT ORIENTAT ION When installing the fixture in a location where the mounting bracket is underneath the fixture you need to change the orientation of a color filter and a gobo inside the product to ensure that the image that is projected is not upside down 1 Ensure that the fixture is disconnect from power and has been allowed it to cool for 5 minutes 2 Remove the thumb scre...

Страница 11: ...mp side using a flat head screwdriver and then grasp it with a pair of needle nose pliers from the other side to remove it 5 Change the orientation of the gobo and return it to the holder Note that the painted black side of the gobo should always face away from the lamp 6 The color filter is located just behind the lens Remove the filter from its holder turn it upside down and replace it 7 Close t...

Страница 12: ...rection This switch enables the direction of the flames to always move up regardless of whether the fixture is installed with the mounting bracket on top or underneath Adjust effect rotation speed This dial is used to adjust the speed at which the flames rise Effect speed Power on switch Effect direction rotation direction rotation speed ...

Страница 13: ...Operation 13 FOCUSING T HE MANI A DC2 The focus is adjusted using the mechanism next to the lens Pull the mechanism out or push it in until a sharp image is acquired ...

Страница 14: ...uses overheating and damage to the fixture that is not covered by the warranty Cleaning the air vents To maintain adequate cooling dust must be cleaned from the air vents periodically Remove dust from the air vents with a soft brush cotton swab vacuum or compressed air Cleaning optical components Clean the optical components regularly The presence of smudges or dust on optical surfaces can reduce ...

Страница 15: ...rface lift the particles off with a soft repeated press 6 Remove smoke and other residues with cotton swabs or unscented tissues moistened with isopropyl alcohol A commercial glass cleaner may be used but residues must be removed with distilled water Clean with a slow circular motion from center to edge Dry with a clean soft and lint free cloth or compressed air 7 Close the fixture cover and tight...

Страница 16: ...f operation Warning Installing any other lamp may damage the fixture Installing a lamp in the Mania DC2 1 Disconnect the fixture from power and allow it to cool for 5 minutes 2 Remove the thumb screw holding the cover in place 3 Slide the fixture cover open as far as possible there is a physical stop point that prevents access to the power supply section Thumb screw ...

Страница 17: ...or protection against current overload An indication that the fuse may have blown is that when power is applied and the lamp is switched on no light is produced If the fuse blows repeatedly there is a fault with the unit that requires service by a Martin technician Never bypass the fuse or replace it with one of another size or rating Replacing the main fuse 1 Unplug the mains cable from the input...

Страница 18: ... power is applied and the lamp is switched on but does not light then check and replace fuse if necessary Burned out lamp Install new lamp Fixture to hot Allow to cool Improve air flow around fixture No action Electrical malfunction Refer to a Martin service technician Fuse blows repeatedly Electrical malfunction Refer to a Martin service technician ...

Страница 19: ...mum distance to flammable material 0 3 m 1ft Minimum distance to illuminated surface 1 0 m 3 3ft Minimum clearance around air vents 0 1 m 4in E L E C T R I C A L Input 3 prong IEC male socket AC Power switch selectable operating ranges 115 120 V 220 240 V 50 60 Hz Main fuse 2 AT time delay T Y P I C A L PO W E R A N D C U R R EN T 120 V 50 Hz 118 W 1 A 120 V 60 Hz 117 W 1 A 230 V 50 Hz 109 W 0 5 A...

Страница 20: ... S V E R S I O N 3 m 9 8 ft EU mains cable 3x1 0mm2 with Schuko male connector 3 m 9 8 ft EU mains cable 3x1 0mm2 with no male connector Philips 12V EFP 8H 100W lamp User manual A C C E S SO R I E S Philips 12V EFP 8H 100W lamp P N 97000004 Half coupler clamp P N 91602005 Fuse 2 AT P N 05020009 O R D E R I N G I N F O R M A T I O N Mania DC2 US version P N 90430021 Mania DC2 non US version P N 904...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...www martin dk Olof Palmes Allé 18 8200 Aarhus N Denmark Tel 45 8740 0000 Fax 45 8740 0010 ...

Отзывы: