3 Fasten the mounting plate to the mounting surface using four 4 mm (1/6th
in) mounting hardware that is able to bear the 6.7 kg (14.8 lbs) weight of the
fixture.
To ensure adequate ventilation, we recommend that the Cyclo 04 DMX be
installed with a minimum of 25 mm (1 inch) of free space on each side.
Screw the fixture into place using, either:
4 Reattach the fixture to the mounting plate and lock it into place by tightening
the two Phillips screws on the side of the mounting plate.
A C P O W E R
Maximum power usage data for the Cyclo 04 DMX is supplied in
“Specifications - Cyclo DMX” on page 21.
Warning:
Cyclo 04 DMX fixtures incorporate four electronic ballasts that
“leak” a total of between 0.8-4mA of power. Because of this we
recommend connecting a maximum of seven Cyclo 04 DMX
fixtures per phase on a 30mA HPFI circuit breaker.
A normal 30 mA HPFI circuit breaker normally trips because of a
current fault or leakage of approximately 20mA. It is important
that the installation is carried out correctly in order to avoid
unintentional tripping of the circuit breaker.
Many installations use common neutral leads in branch circuit
distribution boxes. It is important that the neutral lead in the
cable is connected to the same HPFI circuit breaker, that it is
not connected to the neutral leads from other HPFI circuit
breakers. The neutral lead must be only associated with that
specific circuit breaker. Additionally it is important that the
fixtures are connected correctly to the ground (earth) to ensure
that the power leakage is able to run off.
You can power Cyclo 04 DMX fixtures by wiring them in series. The internal
wiring of the fixtures carries AC power through the fixture. Male and female
Ensto connectors are provided at opposite ends of the fixture for input and
output cables. AC power is connected into the fixture via the female