Troubleshooting
29
Troubleshooting
Problem
Probable cause(s)
Remedy
No response from fixture when
power is applied.
In stand-alone mode, DIP
switch pin 8 set to ON (pause).
Set DIP switch pin 8 to OFF to
resume stand-alone program.
No power to luminaire.
Check power connections.
No power to lighting track.
Check power connection to
lighting track.
Ground fault protection circuit
breaker (RCD) has tripped.
Reset RCD. If problem
persists, have an electrician
replace the RCD or reduce the
number of fixtures powered
via one RCD.
Fixture does not respond
correctly to DMX control.
Controller not connected.
Check DMX data link. Inspect
connections and test cables.
Repair or replace as
necessary.
Incorrect DMX addressing.
Check address setting on
fixture and controller.
Data link not terminated.
Insert RJ-45 termination plug
in unused socket of last fixture
on data link.
Two devices transmitting on
link.
Check that all luminaires are
set as slaves (DIP switch pin 9
ON).
Defective luminaire.
Bypass luminaires one at a
time until normal operation is
regained.
Fixtures do not behave
correctly in master/slave mode
Two luminaires transmitting on
link.
Check that only one luminaire
is set to operate as master.
Defective luminaire.
Bypass luminaires one at a
time until normal operation is
regained.
Poor quality light output and/or
color rendering.
Tube or tubes not burnt in.
Run luminaire for at least 100
hours to burn in tubes.
Tube defective.
Disconnect luminaire and
replace tube.