Making Bias Adjustments to the Meter
The meter reading can be adjusted to match another meter’s reading. The pre
-
programmed crop calibrations can be adjusted individually by +/
-
1.5%, as follows:
Measure the moisture content
of a sample in the normal way
(see page 7)
To remove the bias:
Press
while pressing
. The
+/
-
will disappear.
Note:
Bias adjustments are separate for each crop and stored in the
instrument’s memory until removed as above. Bias adjustment can also be made
when using the Moisture & Temperature or Bale Moisture Probes (see Page 14).
Temperature readings cannot be adjusted.
Meter Calibration Adjustment
To increase the bias:
Press and hold to display the
%H
2
O
value
and press
Λ
to increase the calibration bias in
increments of 0.1
+/
-
appears at the top of the display to
indicate that a calibration has been
adjusted
To decrease the bias:
P
ress and hold and press
V
to decrease the
bias in increments of 0.1.