Step 1 

-

 Prepare the Meter

 

Disconnect any external probe; leave the meter to switch OFF.

 

 
 
 
 
 
 
 
 

 

 

Check the Grinder

-

Compressor is clean (see Page 12 for cleaning instructions). 

Ensure the compressor plunger is fully retracted, as follows:

 

 

 

Step 2 

-

 Prepare the Sample

 

Taking a Moisture Reading

 

 

Place the Grain Cup on the 

Grain Cell

 

Ensure the Grain Cell is clean 

 

Align  the  Black  Pips  on  the 

handle with the Yellow 

 

Slide  the  selector  inwards  to 

the Compress position

 

Rotate  handle  anti

-

clockwise 

until it clicks a few times

 

Slide  the selector  outwards  to 

the Grind position 

 

Place the Grinder

-

Compressor 

over the Grain Cup

 

Lock  in  place  by  twisting  

clockwise against the lugs

 

Using the Spoon, pour a 10 ml 

sample into the Grain Hopper

 

Rotate  handle  clockwise  until 

there is no grinding noise 

 

Ensure  the  yellow    remains 

stationary during grinding

 

X

 

+

 

+

 

Содержание Grainmaster i2-S

Страница 1: ...Martin Lishman Grainmaster i2 S Professional Crop Moisture Measurement Distributed by Martin Lishman Ltd Tel 44 0 1778 426600 www martinlishman com Instruction Manual GRN3000i2 S...

Страница 2: ...2 Other products in the Martin Lishman range See our website for further details www martinlishman com...

Страница 3: ...hip your moisture meter with the latest firmware but updates will become available You can update your meter with the use of the included USB cable and a Windows PC If you are using the Grainmaster mo...

Страница 4: ...usted manually Page 9 Display Bias Set Always use Automatic Temperature Correction ATC ATC adjusts readings if a sample is not at 20 C The default setting is ATC switched ON Page 10 Display flashing A...

Страница 5: ...Standby Mode Optional External Probe Socket USB Socket Meter Functions Items supplied Grain Hopper Yellow Black Pips Cleaning Brush Grinder Compressor Quick Check Grain Cup Grain Cell Spare Grinder B...

Страница 6: ...Ensure the Grain Cell is clean Align the Black Pips on the handle with the Yellow Slide the selector inwards to the Compress position Rotate handle anti clockwise until it clicks a few times Slide th...

Страница 7: ...roximately 7 seconds note and record this value as required To change the crop type Display Codes _ _ _ Standby mode U R Under measurement range The sample is too dry or too cold Can also display if t...

Страница 8: ...3 27 4 30 0 Sorghum Milo Ground 10 2 11 7 12 4 13 1 13 9 14 6 15 4 15 6 16 3 17 1 17 9 18 7 19 6 20 9 22 2 23 7 25 4 Soya Beans Ground 7 4 8 2 8 8 9 7 10 4 11 1 11 8 12 0 12 6 13 4 14 3 15 2 16 0 17...

Страница 9: ...ate for each crop and stored in the instrument s memory until removed as above Bias adjustment can also be made when using the Moisture Temperature or Bale Moisture Probes see Page 14 Temperature read...

Страница 10: ...rature Correction ATC corrects the moisture reading automatically Even with ATC on the grain sample and the meter Grain Cell need enough time to reach close temperature equilibrium If there are extrem...

Страница 11: ...meter version information will appear on screen before entering the setup menu The button Skip is used to navigate through the setup menu The and V buttons are used to change the selected parameter T...

Страница 12: ...e battery if not used for long periods When battery power is low displays A spare battery is included with the meter Separate the two halves of the unit by twisting the yellow locking ring anticlockwi...

Страница 13: ...t Quickcheck readings will reflect this Example Quickcheck reading is 17 1 cell temperature is 17 C wheat calibration is biased 0 5 The reading is derived from 16 3 Quickcheck value at 20 C 0 5 bias 0...

Страница 14: ...moisture probe reading Ensure the Grain Cell is clean Do not touch the cell while using the probe Push the probe into the grain or bale and allow a few minutes to stabilise Connect the probe to the me...

Страница 15: ...emperature probe reading Ensure the Grain Cell is clean Do not touch the cell while using the probe Push the probe into the grain or bale and allow the temperature to stabilise Connect the probe to th...

Страница 16: ...he cost of replacement or repair The manufacturers and Martin Lishman Ltd will not be liable for any consequential or indirect loss suffered by purchasers or users of the unit whether this loss arises...

Отзывы: