Meter Settings

 

Default Settings

 

The 

Grainmaster  i2

-

is  supplied  ready

-

to

-

use  with  ATC  on,  no  bias 

adjustments and temperature in °C. 

 

 

To alter default settings

 

Bias is adjusted as described on Page 9. Temperature units can be changed to 

suit personal preference and ATC can be switched off in Setup Mode, as below:

 

 

To enter Setup Mode: 

 

With the meter switched off, press and hold 

 and 

Keep holding 

 and 

 

until 

‘configuration’ 

appears  and  then  release  both  buttons  at  the  same  time. 

The meter version information will appear on screen before entering the setup 

menu. 

 

 

The 

 button (Skip) is used to navigate through the setup menu. 

 

 

The 

Λ 

and

 V 

buttons are used to change the selected parameter.

 

 

The   button is used to save the selected parameter. 

Remember to press save 

each time you make a change. 

 

 

To exit the setup menu, keep pressing 

 (Skip) until you return to the standby 

screen indicated by 

 

 

Note: 

ATC should always be on during normal meter use.

 

 

 

Setup Menu Screenflow

 

 

_ _ _

 

Bluetooth: 

To  turn  on  Bluetooth,  turn  on  your  meter,  press  and  hold 

Λ 

and then press 

.     

will appear on the screen.

 

To turn it off do the same with 

the 

button. 

Note: Auto

-

off is disabled whilst Bluetooth is on.

 

Содержание Grainmaster i2-S

Страница 1: ...Martin Lishman Grainmaster i2 S Professional Crop Moisture Measurement Distributed by Martin Lishman Ltd Tel 44 0 1778 426600 www martinlishman com Instruction Manual GRN3000i2 S...

Страница 2: ...2 Other products in the Martin Lishman range See our website for further details www martinlishman com...

Страница 3: ...hip your moisture meter with the latest firmware but updates will become available You can update your meter with the use of the included USB cable and a Windows PC If you are using the Grainmaster mo...

Страница 4: ...usted manually Page 9 Display Bias Set Always use Automatic Temperature Correction ATC ATC adjusts readings if a sample is not at 20 C The default setting is ATC switched ON Page 10 Display flashing A...

Страница 5: ...Standby Mode Optional External Probe Socket USB Socket Meter Functions Items supplied Grain Hopper Yellow Black Pips Cleaning Brush Grinder Compressor Quick Check Grain Cup Grain Cell Spare Grinder B...

Страница 6: ...Ensure the Grain Cell is clean Align the Black Pips on the handle with the Yellow Slide the selector inwards to the Compress position Rotate handle anti clockwise until it clicks a few times Slide th...

Страница 7: ...roximately 7 seconds note and record this value as required To change the crop type Display Codes _ _ _ Standby mode U R Under measurement range The sample is too dry or too cold Can also display if t...

Страница 8: ...3 27 4 30 0 Sorghum Milo Ground 10 2 11 7 12 4 13 1 13 9 14 6 15 4 15 6 16 3 17 1 17 9 18 7 19 6 20 9 22 2 23 7 25 4 Soya Beans Ground 7 4 8 2 8 8 9 7 10 4 11 1 11 8 12 0 12 6 13 4 14 3 15 2 16 0 17...

Страница 9: ...ate for each crop and stored in the instrument s memory until removed as above Bias adjustment can also be made when using the Moisture Temperature or Bale Moisture Probes see Page 14 Temperature read...

Страница 10: ...rature Correction ATC corrects the moisture reading automatically Even with ATC on the grain sample and the meter Grain Cell need enough time to reach close temperature equilibrium If there are extrem...

Страница 11: ...meter version information will appear on screen before entering the setup menu The button Skip is used to navigate through the setup menu The and V buttons are used to change the selected parameter T...

Страница 12: ...e battery if not used for long periods When battery power is low displays A spare battery is included with the meter Separate the two halves of the unit by twisting the yellow locking ring anticlockwi...

Страница 13: ...t Quickcheck readings will reflect this Example Quickcheck reading is 17 1 cell temperature is 17 C wheat calibration is biased 0 5 The reading is derived from 16 3 Quickcheck value at 20 C 0 5 bias 0...

Страница 14: ...moisture probe reading Ensure the Grain Cell is clean Do not touch the cell while using the probe Push the probe into the grain or bale and allow a few minutes to stabilise Connect the probe to the me...

Страница 15: ...emperature probe reading Ensure the Grain Cell is clean Do not touch the cell while using the probe Push the probe into the grain or bale and allow the temperature to stabilise Connect the probe to th...

Страница 16: ...he cost of replacement or repair The manufacturers and Martin Lishman Ltd will not be liable for any consequential or indirect loss suffered by purchasers or users of the unit whether this loss arises...

Отзывы: