background image

23

Maintenance / Color Calibration Procedure

■  

Screen Cleaning

Periodically clean the screen surface using ammonia-free cleaning wipes (Marshall Part No. V-HWP-K). 

A clean micro-fiber cloth can also be used using only non-abrasive and ammonia-free cleaning agents. 

Do not use paper towels. Paper towel fibers are coarse and may scratch the surface of the polycarbonate 

faceplate or leave streaks on the surface.  Antistatic and fingerprint resistant cleaning agents are recommended. 

Do not apply excessive pressure to the screen to avoid damaging the LCD.

■  

Faceplate Dusting

Dust the unit with a soft, damp cloth or chamois. Dry or abrasive cloths may cause electrostatic charge on the 

surface, attracting dust particles. Neutralize static electricity effects by using the recommended cleaning and 

polishing practice.

■  

Color Calibration Procedure

•  Allow both the unit you want to calibrate and the Minolta® CA-210 to warm up for a minimum of 20 minutes.

•  Attach the CA-210 color probe to the update dongle.

•  With the unit still turned on, insert the update dongle into the service port at the rear of the OR-841-HDSDI.

•  Use the RotoMenu navigation control and go to:

    

Color Menu

 

Color Temp

 

• Cal D65/D93 to calibrate both

 

• Cal D65 to calibrate only D65

 

• Cal D93 to calibrate only D93

 

 

Press enter once to select and again to confirm

•  Follow the on-screen instructions

Notes: 

1. If there is no color probe attached or you make a mistake and try to calibrate the incorrect screen, you will get 

an error message and the screen will default to previous settings.

2. If the calibration process is interrupted while in progress, the current screen settings will be corrupted and the 

calibration process will have to be repeated.

■  

VIDEO INPUT/OUTPUT

HD/SD-SDI Video Input / Output

■  

CONNECTORS

Video Input

 - 2 x BNC Female (75 Ω)

Video Output (Active Loop-Through)

 - 1 x BNC Female (75 Ω)

Parallel Remote

 - RJ-45

Optional Input Slot

Audio Output Jacks 

- 3.5mm Stereo x 2. One Front and One Rear.

Service Terminal

Power Input

 - 4-Pin Male XLR

 

 

Pin 1:  GND

 

 

Pin 2:  N/C

 

 

Pin 3:  N/C

 

 

Pin 4:  +12VDC

■  

ELECTRICAL

Power Consumption

 - 1.5 Amp (Max) @ 12VDC (18W Max)

Voltage Requirement 

- 12VDC (10VDC-18VDC)

■  

MECHANICAL

Содержание ORCHID OR-841-HDSDI

Страница 1: ...OR 841 HDSDI Fully Featured 8 4 Rack Mountable Camera Top Portable LCD Field Monitor Operating Instructions Marshall Electronics...

Страница 2: ...n 14 Aspect Ratio Setting 14 Mono Color 14 H V Delay 14 Shift H 14 Shift V 15 MARKER CONFIGURATION SUBMENU 15 Markers 15 Center Marker 15 Aspect Markers 15 Safety Marker 15 Marker Mat 15 Line Thicknes...

Страница 3: ...ge in real time It displays in full color and can also be displayed in various sizes positions and transparency options The Vectorscope has adjustable gain from 1x to 5x Waveform monitor function The...

Страница 4: ...een Markers A variety of screen markers in 4 3 16 9 and full screen modes allow accurate monitoring of the different aspect ratios used in broadcast environments User Definable Function Buttons Nine u...

Страница 5: ...threaded mounts There is an optional OR 8RK rack mount kit for mounting two OR 841 HDSDI units side by side in a standard 19 rack When used in this configuration the Dual OR 841 HDSDI units occupy 5...

Страница 6: ...Saturation Sharpness Turning the encoder will allow the user to make adjustments to the selected mode ROTOMENU Control Press the ROTOMENU Encoder to access the on screen Menu Turn the encoder to the L...

Страница 7: ...ources supplying at least 1 Amp at 12 Volts IMPORTANT If using a power source other than the included power supply be sure that the polarity of the DC input is correct Pin 1 GND Pin 2 N C Pin 3 N C Pi...

Страница 8: ...ble Formats 8 Format HD SD SDI 480 60i 576 50i 480 60p 576 50p 720 60p 720 50p 720 30p 720 25 720 24p 1080 60p 1080 50p 1080 60i 30PsF 1080 50i 25PsF 1080 48i 24Psf 1080 30p 1080 25p 1080 24p VGA SVGA...

Страница 9: ...CAL D65 CAL D93 RED BIAS 128 to 127 0 is Calibrated Setting GREEN BIAS 128 to 127 0 is Calibrated Setting BLUE BIAS 128 to 127 0 is Calibrated Setting RED GAIN 0 000 to 1 992 x1 00 is Calibrated sett...

Страница 10: ...L MEDIUM LARGE POSITION LEFT TOP LEFT BOTTOM RIGHT TO RIGHT BOTTOM TYPE OVERLAY OVERLAP Y OVER LIMIT 100 0 IRE 0 to 109 1 Y UNDER LIMIT 100 0 IRE 7 3 to 109 1 VECTORSCOPE RETURN LAYOUT NORMAL LAYOUT A...

Страница 11: ...SATURATION SHARPNESS REMOTE RETURN PIN 1 THRU 8 Pin 5 is Ground INPUT 1 INPUT 2 GAMMA 1 0 GAMMA 1 8 GAMMA 2 0 GAMMA 2 2 GAMMA 2 4 GAMMA 2 6 WHITEBLANCE D65 WHITEBALANCE D93 MONO SCAN ASPECT ZOOM HV DE...

Страница 12: ...Main Menu and Navigation Step through menu items by using the RotoMenu control Choose a submenu or select a menu item by pushing the RotoMenu control Return to the previous menu by pressing the F 9 bu...

Страница 13: ...panese D93 White Point x 0 2830 y 0 2980 USER Adjustable Color Bias and Gain CAL D65 D93 CAL D65 CAL D93 RGB Bias and Gain Select this submenu to fine tune the monitor s color balance R G B or execute...

Страница 14: ...ng the remainder of the screen regardless of its original format In 16 9 mode images are scaled to fill the maximum 16 9 portion of the screen 1024 x 576 regardless of its original format Mono Color U...

Страница 15: ...ettings to superimpose one of 6 markers on the screen when in 16 9 mode 4 3 16 9 1 85 1 2 35 1 4 3 and 1 85 1 4 3 and 2 35 1 Safety Marker Use this setting to adjust the safety marker from 80 to 100 O...

Страница 16: ...justs the point at which the level meters will change color from Green to Yellow This is normally the level used for alignment For digital audio in the US the SMPTE standard is 20dBFS 0VU 4dBu The Eur...

Страница 17: ...occupy on the screen when in the Normal mode Choices are Left Top Left Bottom Right Top and Right Bottom Display Type Use this menu to choose how to display the waveform The choices are Overlay or Ove...

Страница 18: ...aque and will block the source video Gain Use this menu to change the gain of the Vectorscope display Normally the Vectorscope displays x1 00 In order to allow a magnified view the gain is adjustable...

Страница 19: ...SIGN SUBMENU F 1 thru F 9 There are nine Function Keys and One Rotary Encoder on the front panel of the OR 841 HDSDI Each of these F keys key may be assigned any one of 31 different functions as requi...

Страница 20: ...Mix Red and Green for Amber Cannot mix R G B for White It will be pink due to white balance Cannot be assigned with separated tallies Left Right Separated Mode Supports R G B tallies on each Left and...

Страница 21: ...r or White Balance Data Requires Confirm action by selecting Confirm again Select Reset RotoMenu control Select Confirm Press RotoMenu control Resetting default will not effect backed up data Backup U...

Страница 22: ...o 40 C RoHs Do not dispose Return to Manufacturer or Authorized Recycle Facility PANEL VIDEO INPUT OUTPUT HD SD SDI Video Input Output CONNECTORS Video Input 2 x BNC Female 75 Video Output Active Loop...

Страница 23: ...s by using the recommended cleaning and polishing practice Color Calibration Procedure Allow both the unit you want to calibrate and the Minolta CA 210 to warm up for a minimum of 20 minutes Attach th...

Страница 24: ...tions or modifications in design or construction void this warranty It is considered normal for a minimal amount of pixels not to exceed three to fail on the periphery of the display active viewing ar...

Отзывы: