OWNER’S MANUAL
MODEL DH5F-333WND – HHC FOR WENDY’S MODERN LAYOUT
MODEL DH5G-3333WND AND DH5H-3WND – HHC FOR WENDY'S IMAGE LAYOUT
162880 RV061214
Copyright © 2013 Marshall Air Systems, Inc.
All Rights Reserved.
6
DEFAULT PRESET VALUES:
DH5F-333WND
DH5G-3333WND
DH5H-3WND
Deck
1
Deck
2
Deck
3
Deck
1
Deck
2
Deck
3
Deck
4
Deck 1
Left Channel Holding Time (min)
60
60
45
N/A
N/A
N/A
N/A
45
Right Channel Holding Time
(min)
60 60 45 60 60 60 60
45
Top Heater Set Point (ºF)
210
210
200
210
210
210
210
200
Bottom Heater Set Point (ºF)
200
200
200
200
200
200
200
200
Drop
Time
(%)
10 10 10 10 10 10 10
10
Pre-heat
(min)
20 20 20 20 20 20 20
20
Pre-heat
Bypass
(ºF)
50 50 50 50 50 50 50
50
0B
DAILY MAINTENANCE
1. Turn off the nugget cabinet and allow it to cool for 20 minutes.
2. Clean nugget cabinet including shelves and base with a damp cloth/rag and a mild cleaner.
DO NOT USE A GREEN SCOTCH BRITE PAD OR ANY OTHER ABRASIVE CLEANING
PAD. THE BLUE SCOTCH BRITE (NO SCRATCH) IS SAFE TO USE.
DO
NOT
USE
CAUSTIC
CLEANING
SOLUTIONS SUCH AS OVEN CLEANER. USE ONLY
MILD, NON-ABRASIVE CLEANER.
DO NOT IMMERSE IN WATER!
3. Clean any debris obstructing openings for cooling fan (on the right side cover top corner) as
well as the openings for middle and bottom deck controllers (located on the right end of the
middle and bottom controller crossbar).
THIS IS CRITICAL TO ACHIEVE PROPER COOLING
OF THE UNIT.
4. Allow sufficient drying time before attempting to use again.
5. Clean and sanitize all pans per Wendy’s operations instructions.
1B