Mars Wind Stopping 16-CSI-Spec 

Revised 10/15/2020 

MARS AIR SYSTEMS, LLC 

 
 

23 24 33.14 – 2 

K.

 

Section 23 22 13- Steam and Condensate Piping: Steam heating piping to units. 

L.

 

Section 26 05 00 – Equipment Wiring: Connections to building power distribution. 

1.3

 

REFERENCES 

A.

 

ASTM A240 / A240M -10 – Standard Specification for Chromium and Chromium. 

B.

 

ASTM A591 / A591M -98 – Standard Specification for Steel Sheet, Electrolytic Zinc-
Coated, for Light Coating Weight (Mass) Application (Withdrawn in 2005, replaced by 
A879/A879M). 

C.

 

ASTM A879 / A879M -06 – Standard Specification for Steel Sheet, Zinc Coated by the 
Electrolytic Process for Application Requiring Designation of the Coating Mass on Each 
Surface. 

D.

 

ASTM A653 / A653M -09a – Standard Specification for Steel Sheet, Zinc Coated 
(Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process. 

E.

 

AHRI 410-2001 – Standard for Forced-Circulation Air-cooling and Air-Heating Coils. 

F.

 

CRN – Canadian Registration Number Coil. 

G.

 

ANSI Z223-NFPA 54 – National Fuel Gas Code/ 

H.

 

NEC – National Electric Code. 

1.4

 

SUBMITTALS 

A.

 

Submit under provisions of Section 01 33 00. 

B.

 

Product Data: Manufacturer's data sheets on each product to be used, including: 
1.

 

Preparation instructions and recommendations. 

2.

 

Storage and handling requirements and recommendations. 

3.

 

Installation methods.  

C.

 

Shop Drawings: Include plans, elevations, sections, and details, indicating dimensions, 
tolerances, materials, fasteners, hardware, finish, piping, electrical wiring diagrams, 
options, and accessories. 

D.

 

LEED Submittals: Provide documentation of how the requirements of Credit will be met: 
1.

 

List of proposed materials with recycled content. Indicate post-consumer 
recycled content and pre-consumer recycled content for each product having 
recycled content. 

2.

 

Product data and certification letter indicating percentages by weight of post-
consumer and pre-consumer recycled content for products having recycled 
content. 

Содержание WMH Unheated Series

Страница 1: ...without notice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA WMH Unheat...

Страница 2: ...tice Such revisions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Table of Contents Pa...

Страница 3: ......

Страница 4: ...see table above for models available CSA Certified to conform to UL 507 US and CSA 22 2 Canada Standards Indoor Outdoor Use Top and wall mounting holes provided 5 8 Cabinet has sufficient strength fo...

Страница 5: ......

Страница 6: ...nged door type door limit switch installation FIG 1 2 Use light gauge materials when field fabricating brackets to activate and deactivate the door limit switch s FIG 2 Figure 2 also shows the typical...

Страница 7: ...6 STD SHOWN 3 Extended Wall Mounting For Tandem Mounting of air curtain over sectional style door use either wall mounting angle brackets or threaded rods 4 Top Mounting Brackets For overhead installa...

Страница 8: ...s The WMI WMH Series can be configured with Flat Bank or V Bank Filter Sections as options GENERAL SAFETY INFORMATION Use this product only in the manner intended by the manufacturer If you have any q...

Страница 9: ...s of the housing Note Bracket Support mounting is not generally recommended for Air Curtains equipped with steam or hot water coils Overhead installation using threaded rods with independent suspensio...

Страница 10: ...blower wheels note direction arrows on the blower wheel housing Correct if needed by changing polarity of three phase power L VERY IMPORTANT Using a clamp meter measure the amperage to each motor and...

Страница 11: ...all the product reverse the procedures above 8 Reconnect the power source to the product 9 If you have any questions regarding the maintenance of the product contact the manufacturer SPECIAL APPLICATI...

Страница 12: ...bstruction on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating below normal speed...

Страница 13: ...ema 1 1 115 1 1 6 2 4 03 015 7124 1096 Genteq Nema 1 1 208 230 1 6 5 9 2 03 015 Nidec Nema 1 1 208 230 1 4 3 6 5 03 014 K55BWJZB 2362 US Nema 1 1 115 1 1 2 1 03 015 US Nema 1 1 208 230 1 3 2 6 3 Black...

Страница 14: ...ninterrupted or error free operation of Mars product Under no circumstance is Mars liable for any of the following 1 Third party claims against you for damages or 2 Special incidental or indirect dama...

Страница 15: ...CLUDES A Air curtains for pedestrian entrances B Air curtains for vehicular entrances C Air curtains for large loading dock doors 1 2 RELATED SECTIONS A Section 05 50 00 Metal Fabrications Concealed s...

Страница 16: ...for Forced Circulation Air cooling and Air Heating Coils F CRN Canadian Registration Number Coil G ANSI Z223 NFPA 54 National Fuel Gas Code H NEC National Electric Code 1 4 SUBMITTALS A Submit under...

Страница 17: ...on B Installer Qualifications Minimum five years documented experience installing products specified in this Section 1 6 DELIVERY STORAGE AND HANDLING A Store products in manufacturer s unopened packa...

Страница 18: ...s indicated d Electrical Characteristics 208 230V AC three phase 19 0 15 8 Amp full load per motor fan e Electrical Characteristics 460V AC three phase 7 9 Amp full load per motor fan f Electrical Cha...

Страница 19: ...vanes with a plus minus 40 degree sweep front to back 2 Air Velocity at Nozzle a WMH 96 2 99 Inch 2516 mm Wide Units 3732 feet min 18 9 m s two 5HP motor fan assemblies b WMH 120 2 123 Inch 3126 mm W...

Страница 20: ...coils for field mounting on air intake side of the air curtain cabinet with opposite end connections 1 Output Air curtain manufacturer s standard one row coils 2 Output Air curtain manufacturer s stan...

Страница 21: ...ch is used to automatically start and stop the air curtain Thermostat is included with optional motor control panel for field installation Provide motor control panel as follows 1 Thermostat Wall moun...

Страница 22: ...3 1 EXAMINATION A Verify that required utilities are in correct location and are of correct capacities for specified products B Verify openings to receive air curtains are plumb level square accurate...

Страница 23: ...asuring air temperature 6 inches off the floor Optimal reading is halfway between the temperature inside and outside the building 3 4 CLEANING A Clean air curtains promptly after installation in accor...

Страница 24: ...ions do not entitle the buyer to corresponding changes improvements additions or replacements for previously purchased equipment MARS AIR SYSTEMS LLC GARDENA CA USA Reference Links Link Description ht...

Отзывы: