WINDGUARD BELT DRIVE (BD) INDUSTRIAL SERIES 

 

 

Installation, Operation and Maintenance Manual 

Please read and save these instructions. Read carefully before attempting to assemble, install, operate, or maintain 
the product described. Protect yourself and others by observing all safety information. Failure to comply with these 
instructions could result in personal injury and/or property damage. Retain these instructions for future reference. 

 

 
OVERVIEW 

 
Mars Air  Curtains  are 
designed to cover door 
openings, providing 
both temperature 
control/environmental 
separation and flying 
insect  control when the 
building’s doors are 
opened. 

Typical 

installation heights are: 
BD-14 Series 
(Environmental Separation up 16’ and Flying Insect 
Control 

14’), BD-18 Series (Environmental 

Separation up 20’  and  Flying Insect Control  18’), 
BD-22 Series (Environmental Separation up 24’ 
and  Flying Insect Control  22’), BD-26 Series 
(Environmental Separation up 28’ and Flying Insect 
Control  26’) and BD-30 Series (Environmental 
Separation up 32’  and  Flying Insect Control  30’). 
The units are typically overhead mounted 
horizontally above the door opening. They can also 
be vertically mounted alongside the opening. 
Heated units must be mounted on the inside or the 
protected side of the opening. The motors used in 
the BD Series range from 5 HP to 30 HP (see 
submittal for details).  
 
All the BD Series come standard with an expanded 
metal air intake grille(s). The BD Series can be 
configured with Flat Bank or V-Bank Sections, as 
options.

GENERAL SAFETY 
INFORMATION

  

Use this product only in 
the manner intended 
by the manufacturer. If 
you have any 
questions, contact the 
manufacturer. 

Only 

qualified personnel 
should install this 
product. 

Installing 

personnel should have 
a clear understanding 
of these instructions 

and should be aware of general safety precautions. 
Improper  installation can result in electric shock, 
possible injury due to coming in contact with 

moving parts, as well as other potential hazards.

 

 WARNING 

When servicing the product, motor may be hot enough 
to cause pain or injury. Allow motor to cool before 
servicing. 

 

 WARNING 

To reduce the risk of fire, electric shock,  or injury to 
persons, observe the following. 
A. Always disconnect, lock and tag power source before 

installing or servicing product. 

B. Installation work or electrical wiring must be done by 

qualified person(s) in accordance with all applicable 
codes and standards, including fire-rated 
construction. 

C. The combustion airflow needed for safe operation of 

fuel burning equipment in the area may be affected 
by the product’s operation.  Follow  the heating 
equipment manufacturer’s guideline and safety 
standards, such as those published by the National 
Fire Protection Agency (NFPA), the American 
Society of Heating, Refrigeration and Air Conditioning 
Engineers (ASHRAE) and local code authorities. 

D. When cutting or drilling into a wall or ceiling, be 

careful not to damage electrical wiring and other 
hidden utilities.

 

Содержание 03-001

Страница 1: ...come standard with an expanded metal air intake grille s The BD Series can be configured with Flat Bank or V Bank Sections as options GENERAL SAFETY INFORMATION Use this product only in the manner int...

Страница 2: ...acket Support mounting is not generally recommended for Air Curtains equipped with steam or hot water coils Overhead installation using threaded rods with independent suspension of coils is recommende...

Страница 3: ...shipped G Verify voltage to the product once more and turn power on H Regardless of whether the product is mounted on the inside or outside of the door opening set the air directional vanes in the dis...

Страница 4: ...ck bearings require periodic greasing depending on use The Zerk fittings are provided on bearing 7 To re install the product reverse the procedures above 8 Reconnect the power source to the product 9...

Страница 5: ...on on intake or discharge Remove obstruction or move air curtain Power leads out of polarity Switch power leads to correct polarity 3 phase models only Blower motor rotating below normal speed Apply p...

Страница 6: ...ema 1 1 115 1 1 6 2 4 03 015 7124 1096 Genteq Nema 1 1 208 230 1 6 5 9 2 03 015 Nidec Nema 1 1 208 230 1 4 3 6 5 03 014 K55BWJZB 2362 US Nema 1 1 115 1 1 2 1 03 015 US Nema 1 1 208 230 1 3 2 6 3 Black...

Страница 7: ...rrupted or error free operation of Mars product Under no circumstance is Mars liable for any of the following 1 Third party claims against you for damages or 2 Special incidental or indirect damages o...