background image

THE MAIN SCREEN – Continued

ICON Specifications
1. H

 = High Temperature Range.

2. R

 = Ready Mode.       = Rest Mode.

3. F1

 = Filter Cycle 1 is running.       = Filter Cycle 2 is running.       = Filter Cycles 1 and 2 are 

both running.

4. O3

 = Ozone is Running. If you don’t see the icon that means the Ozone is OFF.

5. C

 = Cleanup Cycle is Running.

6.

= Wi-Fi icon just indicates that the Wi-Fi link is connected. It does not indicate signal

strength.

7.

 = Invert (or flip) Screen.

8.

= Lights is turned ON.      = Light is Inactive.      = Light is Disabled.

9.

= Music is Active.       = Music is Inactive.       = Music is Disabled.

10. Message Waiting Indicator: The Message Waiting Indicator will show one of the following

icons:

= Fatal error (Spa can’t function until it’s fixed)
= Normal Error or Warning
= Reminder Message
= Information Message.

Touch the Indicator to go to a Message Screen which shows the message.

Some messages will include the “Call for Service” text as it requires a service technician to fix 
the problem.

Touching the Error/Warning/Reminder/Info Icon on the Message Screen will take you to the 
System Information Screen to allow for troubleshooting over the phone or for a field service 
tech to better understand what is going on. Exiting the System Information Screen will take 
you back to the Message Screen in that situation.

11.      = Adjust set temperature higher.
12.

= Spa Equipment Control Icon. Brings up a new screen where the spa jets, and other

equipment can be controlled.
While on the Spa Equipment Screen, you can press a Jets button once for low speed, and
if configured press it again for high speed.

= Jet is Inactive. Indicates if a pump is running or not.

13. Indicates if the temperature is in 

°F

 = Fahrenheit or 

°C

 = Celsius.

14. Current water temperature if 

°F 

or 

°C

 is solid; set temperature if 

°F 

or 

°C

 is flashing.

15. Setting Icon.         = Settings is Active. 
16.

Different animation sequences, including blinking, may indicate different stages of

heating.

17.   

= Adjust set temperature lower.

^

^

2

Содержание spaTouch2

Страница 1: ...ent Control Icon will spin when a pump is in operation ICON Specifications 1 H High Temperature Range 2 R Ready Mode 3 F1 Filter Cycle 1 Running 4 O3 Ozone Running 5 C Cleanup Cycle 6 Wi Fi Signal Ind...

Страница 2: ...Call for Service text as it requires a service technician to fix the problem Touching the Error Warning Reminder Info Icon on the Message Screen will take you to the System Information Screen to allo...

Страница 3: ...rtain times an indicator may appear showing that a message is waiting Touch this indicator to go to the Message Display Screen On that Screen some of the messages can be dismissed A Warning Message is...

Страница 4: ...allation The icon buttons are used to select and control individual devices Some devices like pumps may have more than one ON state so the icon will change to reflect the state of the equipment Below...

Страница 5: ...iting Screens Use the Back button to go back or exit The Back button is on every screen except the Main Screen the Priming Mode Screen or the Message Display Screen When you see only the Back button o...

Страница 6: ...Down button is shown and pressed when on a page with a text list the list can be scrolled a page at a time Page Up Page Down THE SETTINGS SCREEN Programming Etc The Settings Screen is where all progr...

Страница 7: ...low speed and high speed but you cannot turn the heater pump off Circulation Mode See Pumps for other circulation modes If the spa is configured for 24HR circulation the heater pump generally runs co...

Страница 8: ...lowing from the jets in the spa do not allow the pumps to continue to run Turn off the pumps and repeat the process Note Turning the power off and back on again will initiate a new pump priming sessio...

Страница 9: ...erence and usage patterns Setting the filtration cycles for late at night can avoid higher electrical rate costs as an example If you live in a climate that is seasonally hot running the filtration cy...

Страница 10: ...be maintained for several days ADJUSTING FILTRATION Main Filtration Using the same adjustment as Setting the Time Filter Cycles are set using a start time and a duration Each setting can be adjusted...

Страница 11: ...fic Buttons for Specific Devices If the spa has an Auxiliary Panel installed pressing buttons on that panel will activate the device indicated for that button These dedicated buttons will operate just...

Страница 12: ...FCI configured in one of three ways 1 GFCI test is not enabled 2 Manual GFCI test is enabled but automatic GFCI test is not enabled 3 Both manual and automatic GFCI tests are enabled The automatic tes...

Страница 13: ...ticular system System Model Displays the Model Number of the System Panel Version Displays a number of the software in the topside control panel Software ID SSID Displays the software ID number for th...

Страница 14: ...Screen takes you to the GFCI Test screen The installer can cause the GFCI Trip Test to occur sooner by pressing Test on the GFCI Test screen The GFCI should trip within several seconds and the spa sh...

Страница 15: ...cted or the Aux Freeze Switch has closed All water devices are activated In some cases pumps may turn on and off and the heater may operate during Freeze Protection This is an operational message not...

Страница 16: ...in the heater to start it The spa is shut down After the problem has been resolved you must reset the message to restart heater See Flow Related Checks below The heater is too hot M030 One of the wate...

Страница 17: ...m and requires a service call The settings have been reset Persistent Memory Error M021 Contact your dealer or service organization if this message appears on more than one power up The clock has fail...

Страница 18: ...tions must be properly installed CSA Compliance Conformit Caution Test the ground fault circuit interrupter before each use of the spa Read the instruction manual Adequate drainage must be provided if...

Страница 19: ...2 3 4 Messages 1 2 3 Message Waiting Indicator 1 2 Music 1 2 3 N Navigation 3 Normal Error 2 O Ozone 2 9 P Page Up Down 6 Panel Version 13 Polling 7 9 Press and Hold 3 Priming Mode 5 8 12 Programming...

Отзывы: