T R O U B L E S H O O T I N G
LCD DISPLAY MESSAGES (CONTINUED)
SN, Snt or SnH:
A sensor has malfunctioned. The spa will turn off. Contact your service provider.
CL:
This will appear every 30 days as a reminder to clean the filter. (See REMOV-
ING THE FILTER.)
CH:
This will appear every 90 days as a reminder to drain and refill the spa. (See
DRAINING THE SPA and REFILLING.)
FL:
A pressure switch may have malfunctioned. Contact your service provider.
NO HEAT
Check temperature LCD display for desired temperature setting.
NOTE:
Do not expect instant hot water from the jets. It will take the heater 12-24
hours to heat the spa to the temperature you desire.
Check for obstructions or restrictions at the suction fittings.
Inspect the filter cartridge(s) for dirt and debris.
Check that the water is at proper level, 2/3 up the Vortex skimmer opening(s).
Lower ambient temperatures may result in heat loss.
LIGHT DOES NOT WORK
Press the LIGHT ON/OFF pad on the spa side controls.
Reposition the light bulb in the socket. (See REPLACING LIGHT BULB section.)
Replace the light bulb with a
6 WATT BULB ONLY.
M A R Q U I S S P A S • R E L A X I N G Y O U R W O R L D 6 6