120 Volt:
120V units must only be connected to a
properly grounded, grounding type15
amp receptacle. 120V equipment is
designed to operate on 60Hz Alternat-
ing current only at a voltage of 120, 12.5
amp. maximum load.
To Convert 120V to 240V
All connections must be made by a
licensed electrician.
1. Disconnect from power and remove
cord.
2. Move red wire (TB-1) to (TB-4) as
indicated by gray area.
3. Move the Heater Mode selector
(J23) on the Control Board from
(20A) to (50A) position.
Ground Fault Circuit Interrupters
(GFCI), #8145, are available from your
Dealer.
START-UP PROCEDURE
Your spa is equipped with solid state preprogrammed Comfort Controls specific to your spa
model. Please see the CONTROLS section listed under your particular spa series model.
To start your spa, you will need a spa water test kit and an underwater thermometer. It
is important to follow each of these steps when starting your spa.
Leisure Series Models Start-up:
1. Place spa on a hard, flat, level surface. Make sure the power supply is off.
2. Make sure that the suction fittings in the footwell are
in place and undamaged.
3. Open the equipment door. Screw the pump plug
(supplied in packet) into the face of the pump.
Close the drain valve and screw the drain valve cap on
tightly. Tighten all disconnects and open all shut-off
valves. On models Equipped with AWP external
drain, close valve by turning outer ring clockwise. Be
sure the center plug is in place and tighten.
J
I N S T A L L A T I O N I N S T R U C T I O N S
(CONTINUED)
M A R Q U I S S P A S • R E L A X I N G Y O U R W O R L D 1 0
S T A R T I N G Y O U R S P A