 Charge Regulator 

Installation and Operation

Understanding The LCD Display

HRD

i

 Display

Button Functions

: Scroll Button -

Press to scroll through the settings displayed.

: Zero Button -

Press to zero the logged Ah displays.

: Light - Switches the back light on/off.

Default setting is is on for 60 seconds

All three buttons have
further functions when
the HRD

i

 is put into

programme mode. In this
mode the buttons become
selectors where choices
have to be made

WG: 

3.25A  38.0W

6Ah 

After 

2h

1 : 11.7V l Charge

2 :  N/C  l  Bulk

WG

 = Windcharger

PV

 = Solar Panel(s)

NET

 = Combined WG 

+

 PV

(  less Regulation reduction  )

3.25 Amps of
current generated
by the Windcharger
in this case

38 Watts of power
generated by the Windcharger
in this case

6 Amp hours of
stored charge have
been accumulated by
the battery after 2
hours of charging

Battery 1 is 11.7 Volts
Battery 2 is not
connected

Low 

will alternate 

Multistage Charge Mode - Either :

with the voltage
reading for values
below 11.0 V @ 25°C

Charging Mode -
Either :

Charge

-

Current may be
flowing into the
battery bank(s)

Charge/
Reg 

-

Regulation has
begun but some
current may still
flow into battery
bank(s)

Reg

 -

No current is
flowing to the
battery bank(s)
as the mode has
shifted to
Regulation and
the Windcharger
will run very
slowly

Bulk 

- Bulk rapid charging or absorption

stages.

Float

- Float stage maintaining and slowly

building to full charge.

User Guidance

Use the Scroll Button to scroll between 

WG, PV & NET

to see the displays of  current, power inputs and Ah from these

charge sources.The display can be left in any of the three

positions and the quantities refer only to the featured input.

Press once to open the menu for zeroing ALL the Amp hours &

elapsed time previously logged. The NO and YES options are on

the top two buttons.

Charge / Stop Switch should be kept in upper position during
maintenance / setting up. The switch should NOT be operated
during high winds.

Elapsed time
since last reset

Содержание HRDi

Страница 1: ...HRDi Charge Regulator Installation and Operation RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION ...

Страница 2: ... input must be de rated Contact your dealer or the manufacturer for advice May be connected in parallel with other charge sources not through the HRDi For use with a single or dual battery bank Clear alpha numeric digital LCD screen with user display options Push button activated and timer controlled backlight Accepts up to 6 mm2 cable SWG 11 or AWG 9 Optional remote display can be added to dedica...

Страница 3: ...attery positions BAT1 BAT1 and if a second bank is used BAT2 BAT2 It is ESSENTIAL that BAT1 is connected as this link provides internal power for the HRDi Connect BAT2 before BAT1 if both are to be used 7 Connect the 2 Windcharger cables to the Windcharger positions WG WG and the solar panel cables to the solar panel positions PV PV ensuring correct polarity is observed Note Solar panels must be f...

Страница 4: ...d Low will alternate Multistage Charge Mode Either with the voltage reading for values below 11 0 V 25 C Charging Mode Either Charge Current may be flowing into the battery bank s Charge Reg Regulation has begun but some current may still flow into battery bank s Reg No current is flowing to the battery bank s as the mode has shifted to Regulation and the Windcharger will run very slowly Bulk Bulk...

Страница 5: ...ory Setting Default is YES Toggle to NO and press OK to save the changes made Or Press OK and factory settings are restored Note At any time in reprogramming procedure if no button is pressed for 30 seconds then normal operation is returned without any changes being saved It is not recommended that this value be changed for all lead acid batteries Temperature compensation adjusts charging level to...

Страница 6: ...advice 8 Always fit an appropriate blocking diode to each solar panel input 9 Never connect the HRDi to the battery or any charge sources in reverse polarity 10 Avoid exceeding the recommended wiring distance between HRDi and battery Longer distances require heavier gauge cable or charging efficacy will be affected 11 Never obstruct the ventilation slots of the HRDi Please take note of these steps...

Страница 7: ...me WG Windcharger HRDi Charge Regulator PV Solar Module Max 160 W BLOCKING DIODE MUST BE FITTED Battery 1 WG WG PV PV BAT BAT BAT2 BAT2 Cut Away of HRDi Wiring Block Wiring block Parallel panels each require a blocking diode Battery 2 In Line Fuse Supplied With Windcharger ...

Страница 8: ...egulator Installation and Operation Sunshine Solar Limited Unit 30 Ashwellthorpe Industrial Estate Ashwellthorpe Norwich Norfolk NR16 1ER Tel 44 0 1508 488 188 Email sales sunshinesolar co uk www sunshinesolar co uk ...

Отзывы: