background image

 
 

 

 
3. Mounting systems 

 

 Attention!: 

Basically the following is applicable for all mounting systems: 
 
  1.  The mounting material manufacturers (e.g. Fischer, Hilti, Upat, etc.) offer different mounting systems 

according to the undersurface. If the conditions for the mounting are met according to DIN EN 13561, 
the wind resistance class 2 or 3 for the mounting can be confirmed to the user (see sales information 
"dimensions and features").

 

 
  2. Mounting material is not supplied automatically, as different subsurfaces (e.g. concrete, lime sand 

stone, autoclaved aerated concrete etc) require different types of mounting material. 

 
  3. IMPORTANT: Mounting brackets have to be aligned with each other! When subsurfaces are uneven, the 

clearances are to be checked using a cord pulley and if required compensated accordingly. 

 
3.1 Niche mount 

with motor drive 

 

 

 

 

 

 

 

Measurements 

in mm

 

with manual drive 

 

 

 

 

 

 

 

Measurements 

in mm

 

  1. Determine mounting height. Mark the position 

of the brackets on the mounting surface (see 
„mounting area of the brackets“). 

 
  2. Mark drillings on axial dimensions and drill 

(screws M 6). 

 
  3. Fix bracket. Depending on the size of the verti-

cal awning, fix additional brackets between the 
outer brackets brackets concentrically and/or in 
regular spacings.  

 

 Attention!: Measure all brackets diagonally!

 

 

Содержание 869

Страница 1: ...gle below 25 14 measured from the horizontal Danger of frost and snow X not permitted Date Signature of installation engineer Signature of user The European standard DIN EN 13561 establishes the requirements for the construction and fastening of awnings The construction of this markilux awning fulfills the requirements of the Wind Resistance Class 2 specified in the CE mark of conformity The wind ...

Страница 2: ...gle below 25 14 measured from the horizontal Danger of frost and snow X not permitted Date Signature of installation engineer Signature of user The European standard DIN EN 13561 establishes the requirements for the construction and fastening of awnings The construction of this markilux awning fulfills the requirements of the Wind Resistance Class 2 specified in the CE mark of conformity The wind ...

Страница 3: ...ing profile with fabric roller 2 Mounting bracket 3 Guide rail 4 Fabric 5 Projection profile 2 Mounting brackets 2 1 Overview mounting brackets Mounting type 10 Mounting type 15 Mounting type 20 78548 78719 with 78548 78451 Further mounting brackets can be found in the sales information ...

Страница 4: ... mm Dimensions in mm for manual drive IW Dimensions of niche M Awning width MA Axial dimension of awnings H Drop GA Total projection TB Fabric width AS Drive side 1 Bracket Mounting type 20 Dimensions in mm Dimensions in mm for manual drive M Awning width MA Axial dimension of awnings H Drop GA Total projection TB Fabric width AS Drive side 1 Bracket Attention From 301 cm drop 3 brackets per rail ...

Страница 5: ...aved aerated concrete etc require different types of mounting material 3 IMPORTANT Mounting brackets have to be aligned with each other When subsurfaces are uneven the clearances are to be checked using a cord pulley and if required compensated accordingly 3 1 Niche mount with motor drive Measurements in mm with manual drive Measurements in mm 1 Determine mounting height Mark the position of the b...

Страница 6: ...Pull variable webbing into the guide rail by pushing of the glider 7 in direction of the projection profile 8 5 Push left guide rail 4 into the socket of the left side cover 5 until the stop 6 Attention The variable webbing 6 must not be twisted 7 Tighten the threaded pin 18 well Attention The threaded pin should be screwed in except for approx 2 thread pitches check fit of guide rail 8 Remove the...

Страница 7: ...4 direct with the clamping jaws 19 of the brackets SW 6 5 Motor driven awning 5 1 Motor connection The electrical connection for the motor drive and or control system connection is to be carried out accord ing to the instructions of the manufacturer of the motor and control system Modifications especially in the motor s the control system s and the connecting cable s area require a written permit ...

Страница 8: ...6 5 2 Motor connection data markilux 869 with radio control 433 MHz U 230 V 170 W 50 Hz I 0 80 A Motor drive without radio control U 230 V 215 W 50 Hz I 0 92 A ...

Страница 9: ...ons of the motor switch and controller manufacturers are to be handed over to the user with a written confirmation and fitted wind class see handover declaration He is to be comprehensively enlightened about the safety and usage information of the awning With non observance and malop eration the awning can suffer damage and accidents can occur 4 Working at greater heights If the awning unit has to...

Страница 10: ...y If awnings are operated by several users a priority switching interlocking device con trolled power interruption from outside must be installed which makes any extending and retracting of the awning impossible 9 Proper intended use Awnings may only be used for the purpose defined in the operating guide Modifications such as add ons and conversions not intended by the manufacturer may only be per...

Отзывы: