Installation in solid wood/engineered wood
Installation in concrete/reinforced concrete/hollow concrete/solid brick/sand-lime brick
Installation in steel
1. Drill holes
1. Drill holes
1. Drill holes
2. Install MARK Gekko Vario
2. Install MARK Gekko Vario
4. Install MARK Gekko
Vario
2. Clean holes
3. Fill holes with injection
mortar
Discard initial mortar
Screws:
talternating rotary mo-
tion when pressing
Caution: Do not over-tighten screws!
NOTE
12
4 INSTALLATION
This product may only be installed in accordance with the instructions in these instruc-
tion manual and with the installation materials (screws, mortar) supplied by MARK
Save A Life . MARK Save A Life recommends it is installed by a specialist company.
4.1.1 Concrete
65Nm
Video instructions for correct assembly are provided and must be followed! It is neces-
sary to contact MARK Save A Life GmbH!
NOTE
If the substrate cannot be clearly identified, a pull-out test or a substrate test must be
carried out in accordance with EN 795 or TS 16415
WARNING
13
Hollow concrete
Reinforced concrete
Certification
EN 795 : 2012 class A1, TS 16415 : 2013
EN 795 : 2012 class A1, TS 16415 : 2013
Screws
NIRO M10 A2-80
ø 10 x 160mm
NIRO M10 A2-80
ø 10 x 100mm
Drill
Masonry drill
ø 12mm
Setting depth in the load-bearing
subsurface
≥
80mm
Quality and installation base
≥
C20/25 cracked reinforced concrete
Composite mortar
Würth WIT-VM250, Fischer FIS AB 300T, Hilti HIT-HY 170
Remarks
Clean the boreholes with a perforated brush and blow them out according to the
manufacturer’s instructions and instructions for use of the adhesive
Distance from edge
≥
200mm
≥
55mm
Installation base
Drilled holes in concrete core
Deformation
Maximum expected deformation due to
a fall from a height
≤
50mm
Maximum expected deformation due to
a fall from a height
≤
50mm
Permissible installation positions
Number of users: 1 person
Number of users: 2 persons