14  INSPECTION REPORT

2021

2022

2023

2024

2025

2026

2027

2028

2029

2030

 

1

2

3

4

5

6

7

8

9

10

11

12

13

C

us

tom

er

:

Si

gnat

ur

e c

us

tom

er

:

M

AR

K S

av

e A

 L

ife G

m

bH

, G

lei

nker

au

 23,

 A

-4582 S

pi

tal

 am

 P

yh

rn

, +

43 7563 8002 111,

 m

ar

k@

sav

eal

ife.

at

INSPECT

IO

N PRO

TO

CO

L/

Vis

ua

l in

sp

ec

tio

n

 A

nc

hor

 poi

nt 

MA

R

G

ek

ko 

Var

io 

Annual

 ins

pec

tion

R

em

ar

ks

:

Si

gnat

ur

e qual

ified per

son:

D

at

e of

 ins

pec

tion:

  m

ont

h/

year

Anc

hor

 poi

nt

 is

 in pr

oper

 c

ondi

tion

and c

an be us

ed

Ins

ta

lla

tion

Annua

lly

Buc

kl

e f

ol

ds

 bac

k and l

oc

ks

 agai

n w

ithout

 

inc

reas

ed ef

for

t

The anc

hor

 poi

nt

 is

 dam

aged or

 no l

onger

 

func

tional

 and w

as

 m

ade i

noper

at

iv

e (

by

 

rem

ov

ing t

he buc

kl

e)

.

The anc

hor

 poi

nt

 m

us

t be r

epl

ac

ed.

N

o c

or

ros

ion at

 the anc

hor

 poi

nt

 v

is

ibl

e

N

o c

rac

ks

 or

 tear

s at

 the anc

hor

 poi

nt

 v

is

ibl

e

N

o def

or

m

at

ion at

 the anc

hor

 poi

nt

 det

ec

tabl

e

(If

 poi

nt

s 1-

11 ar

e c

hec

ked,

 12 c

an 

be c

hec

ked as

 w

el

l -

 ot

her

w

is

e 13)

 

Resu

lt o

f t

he 

vi

su

al

 in

sp

ect

io

n

Al

l s

cr

ew

s c

hec

ked f

or

 ti

ght

nes

s

Th

is

 p

ro

du

ct

 m

us

t b

e i

ns

pe

ct

ed

 a

t l

ea

st

 o

nc

e a

 y

ea

r b

y a

 q

ua

lif

ie

d p

er

so

n.

 D

ep

en

di

ng

 o

n t

he

 e

nv

iro

nm

en

t a

nd

 in

te

ns

ity

 o

f u

se

 a

ls

o m

or

e o

fte

n.

 T

he i

ns

pec

tion i

s s

ubj

ec

t t

o f

ol

low

ing c

ondi

tion

s:

 T

he pr

oduc

t has

 been 

in

st

al

led ac

cor

di

ng t

o t

he us

er

 m

anual

 pr

ov

ided by

 the m

anuf

ac

tur

er

, c

om

ponent

s of

 thi

s pr

oduc

t hav

e not

 been m

odi

fied or

 al

ter

ed and i

t has

 not

 been ex

pos

ed t

o t

em

per

at

ur

es

 bel

ow

 -40 °C

 or

 abov

e +

 150 °C

. F

ill i

n t

he 

in

spec

tion pr

ot

oc

ol

 c

ar

ef

ul

ly and k

eep i

t s

tor

ed ac

cor

di

ng t

o l

egal

 requi

re

m

en

ts

.

Ins

tal

lat

ion pr

ot

oc

ol

l c

om

pl

et

e

Subs

truc

tur

e f

irm

 and s

tabl

e

Buc

kl

e c

an be f

ol

ded out

 by

 tappi

ng

Phot

o r

ec

or

d of

 ins

tal

lat

ion av

ai

labl

e

Anc

hor

 poi

nt

 av

ai

labl

e and

pr

oduc

t i

dent

ific

at

ion r

eadabl

e

U

ser

 m

anual

 av

ai

labl

e

Layout plan with position of anchor devices:

NOTES

25

          

 

 

Содержание Gekko Vario

Страница 1: ...43 7563 8041 111 mark savealife at www savealife at MARK Gekko Vario Instruction manual Anchor point Personal protective equipment PPE against falls from a height EN 795 2012 Class A1 TS 16415 2013 E...

Страница 2: ...d this instruction manual Always keep the instruction manual the installation report and the inspection report to gether with the other relevant product documents for future reference If the instructi...

Страница 3: ...AGE 17 6 MAINTENANCE 17 6 1 Repairs 17 6 2 Cleaning 17 7 CHECKS 18 7 1 Visual and functional inspection 18 7 2 Periodic inspections 19 8 DISPOSAL 19 9 RE SALE 19 10 ACCIDENTS 19 10 1 Suspension trauma...

Страница 4: ...eets the applicable technical standards for PPE and the requirements of the Austrian PPE Safety Regulation 1 1 Symbols used This instruction manual contains safety regulations in the following categor...

Страница 5: ...sed in conjunction with tested certified and approved accessories that meet the applicable technical standards for PPE and the require ments of the Austrian PPE Safety Regulation PSA Sicherheitsverord...

Страница 6: ...y Regulation Classed as tested accessories Descender and rescue devices Lifting devices Retractable fall arrest blocks Guided type fall arresters on fixed anchor lines Guided type fall arresters on fl...

Страница 7: ...er location The anchor point must be inspected by a competent person before being installed again The product must be re installed according to the MARK Gekko Vario installation instructions Always cr...

Страница 8: ...MARK Save A Life GmbH NOTE If the substrate cannot be clearly identified a pull out test or a substrate test must be carried out in accordance with EN 795 or TS 16415 WARNING 13 Hollow concrete Reinf...

Страница 9: ...tion Maximum expected deformation due to a fall from a height 50mm Permissible installation positions Number of users 1 person 14 15 Solid wood wall ceiling Certification EN 795 2012 class A1 TS 16415...

Страница 10: ...d securely in the installation base may only be performed by specialist companies Only MARK Save A Life may modify this product or add to it If it seems unsafe to continue using this product do not us...

Страница 11: ...entered in the inspection report The frequency of the inspection will depend on how often and how intensely the product is used as well as on the operating environment If the product is subjected to...

Страница 12: ...AL INFORMATION Do not remove any stickers or labels from this product We recommend that you give this product an inventory number and enter it in the inspection report 11 1 Declaration of compliance T...

Страница 13: ...fied screws used Any insulating layers or plaster coats taken into account Photographs taken MARK Gekko Vario Securely anchored in installation base No corrosion No cracks No deformation Buckle can be...

Страница 14: ...ation at the anchor point detectable If points 1 11 are checked 12 can be checked as well otherwise 13 Result of the visual inspection All screws checked for tightness This product must be inspected a...

Страница 15: ...to technical modifications The latest version shall always apply We only guarantee that our materials are in perfect working order All rights reserved It is only permitted to make changes to reprint...

Отзывы: