4.4 Dwell times (DWELL CW and DWELL CCW)
This setting corresponds to the amount of time, in seconds, for which the torque plate stops at the limit
during a cycle sequence. Individually set dwell times can be applied to the CW and CCW limits.
Note:
The dwell time setting is unavailable for an auto return sequence.
Default setting: 0 (no dwell time)
Available settings: 0 – 9999.9
Label
Description
+
Increases dwell time in increments of .1. Holding down
+
will increment at an
increasingly faster rate. If 9999.9 is reached the next number will be 0 and
continue incrementing.
–
Decreases dwell time in increments of .1. Holding down
–
will decrement at
an increasingly faster rate. If 0 is reached the next number will be 9999.9
and continue decrementing.
ENTR
Returns to the Test Function Setup menu
ESC
Exits the function without saving changes
4.5 CW and CCW travel limits (CW L and CCW L)
This setting corresponds to the rotational travel distance the test stand moves before stopping or cycling.
CW and CCW limits are programmed individually. The programmed distances are relative to the zero
position of the test stand. The travel indicator can be zeroed by pressing and holding STOP for three
seconds.
Default settings: 1 revolution
Available settings: ±2,777.77 revolutions
Label
Description
+
Increments the travel limit setting. Holding down + will
increment at an increasingly fast rate.
–
Decrements the travel limit. Holding down
–
will increment at
an increasingly fast rate.
ENTR
Returns to the Test Function Setup menu
ESC
Exits the function without saving changes
C W D W EL L: 0 0 0 0 . 0
E S C − + E N T R
C W LM : 2 . 0 5
E S C − + E N T R
Содержание TSTM-DC
Страница 1: ...Series TSTM DC Motorized Torque Test Stands User s Guide...
Страница 23: ...Series TSTM DC Test Stands User s Guide 23 10 DIMENSIONS in mm TSTM DC...
Страница 24: ...Series TSTM DC Test Stands User s Guide 24 TSTMH DC CONTROL PANEL...
Страница 25: ...Series TSTM DC Test Stands User s Guide 25 NOTES...