background image

 

 

Model ESM301 Programmable Force Test Stand 

 

 

 

 
 
 
 
1.  Fuse

 

   

2.  Controller Cable Connector

 

 

Plug one end of the cable into this connector, and the other end 
into the connector as shown in the illustration on the following 
page. If this cable is not connected, the error message  

 

ENCODER ERROR 

will be shown on the display and the test 

stand cannot be operated. 

 

3.  PC Control Connector 

 

 

Plug one end of the 09-1056 serial cable into this connector, and 
the other end into a serial connector on a computer.  

 

4.  Power Plug Receptacle 

 

 

Plug the power cord in here. 

 

5.  Travel Indication Connector 

 

 

Plug one end of the USB/RJ11 cable into this connector, and the 
other end into the mini USB connector in the rear of the cross-
head.  

  

6.  Force Gauge Cable Connector  

 

 

Plug one end of the 09-1143 cable into this connector, and the 
other end into a Series BG force gauge. 

Содержание ESM301

Страница 1: ...User s Guide Force Test Stands Series ES User s Guide MODEL ESM301...

Страница 2: ...and industrial environ ments This User s Guide provides setup safety and operation instruc tions Dimensions and specifications are also provided For addi tional information or answers to your question...

Страница 3: ...acility allows the user to enable features not originally pur chased through a code activation process Qty Item 1 ESM301 test stand 4 Force gauge mounting screw 1 User s guide this booklet 1 Power cor...

Страница 4: ...ch a way that it is prevented from slipping out during a test preventing a potential safety risk to the operator and others in the vicinity If using a grip or fixture from a supplier other than Mark 1...

Страница 5: ...able and secure position install a force gauge with four thumb screws provided All Mark 10 gauges except the Series CG mount directly without adapters Grips can be mounted onto the force gauge and tes...

Страница 6: ...and cannot be operated 3 PC Control Connector Plug one end of the 09 1056 serial cable into this connector and the other end into a serial connector on a computer 4 Power Plug Receptacle Plug the powe...

Страница 7: ...ed 1 Never operate the test stand if there is any visible damage to the power cord or the test stand itself The ESM301 is powered by 110V 220V Any contact with this high voltage can cause serious inju...

Страница 8: ...SM301 has relatively slow moving mechanisms be aware of the dangers posed by potential energy that can accumulate in the sample during testing Extra bodily protection should be worn if a destructive f...

Страница 9: ...RGENCY STOP SOFT KEYS UP STOP ZERO TRAVEL DISPLAY DOWN DISPLAY SOFT KEYS Functions are determined by the correspond ing text on the display UP Commences movement in the up direction DOWN Commences mov...

Страница 10: ...res only installed features will be displayed in Test Parameter Setup The initial Test Parameter Setup screen appears as follows When the parameters have been configured as desired and are Parameter S...

Страница 11: ...ETURN CYCLES UPPER DWELL LOWER DWELL UNITS KEYS DEFAULT SETTINGS NEW PASSWORD OPERATING MODE ENTR ESC ENTR inc dec ENTR ESC ENTR ENTR ESC ENTR on off ENTR ESC ENTR ENTR ESC ENTR ENTR ESC ENTR ENTR ESC...

Страница 12: ...e the crosshead moves to a limit switch force set point or travel distance whichever occurs first and stops Then the crosshead returns to the other limit and stops The test speed is dictated by the SP...

Страница 13: ...rosshead moving to a limit switch force set point or travel distance whichever occurs first at the specified speed stop ping for the specified amount of dwell time and returning to the other limit at...

Страница 14: ...of cycles in incre ments of 1 Holding down will increment at an increasingly faster rate If 99999 is reached the next number will be 00000 and continue incrementing Decreases the number of cycles in...

Страница 15: ...faster rate If 9999 9 is reached the next number will be 0 and con tinue incrementing Decreases dwell time in increments of 1 Holding down will decrement at an increasingly faster rate If 0 is reache...

Страница 16: ...1V 2V 4V OFF 5 7 Compression and Tension Overload Settings C OVERLOAD and T OVERLOAD The setting corresponds to the percentage of full scale of the force gauge at which crosshead travel stops For exam...

Страница 17: ...changed on the front panel these settings will be ig nored except for Auto Return or Cycling If either of these pa rameters are turned on PC control will be turned off Default setting CONSOLE Availabl...

Страница 18: ...ling the test stand Default setting 8 1n Available settings 8 1E 8 stop bits 1 stop bit even parity 8 1o 8 stop bits 1 stop bit odd parity 8 1n 8 data bits 1 stop bit no parity 8 2n 8 data bits 2 stop...

Страница 19: ...tly pressing the UP DOWN or STOP during a test will stop crosshead mo tion 2 Momentary The crosshead will move only if the button is held STOP PAR 8 1 n ESC ENTR _ or Cycles through the available sett...

Страница 20: ...P during maintained mode will stop crosshead motion Default setting maintained Available settings maintained momentary auto 5 13 Default Settings DEFAULT This setting provides a quick return to factor...

Страница 21: ...setting of 0000 indicates that the pass word is disabled and that the user can freely enter the Test Pa rameter Setup menu If misplaced or forgotten the password may be reset through a code activatio...

Страница 22: ...it or set point for a selected pe riod of time 4 PC Mode Test stand is controlled through a serial connection with a computer The Operating Mode screen appears as follows Increases the number in incre...

Страница 23: ...corresponds to crosshead speed in both directions 6 2 Menu Navigation At power up the display will show the operation screen for which ever mode was used last The display will appear as one of the fo...

Страница 24: ...Auto Return modes Pressing menu will enter Test Parameter Setup If a password has been programmed the display will prompt the following The password is a four digit number The first digit in the pass...

Страница 25: ...on has been pressed Subsequently pressing STOP during a test will stop crosshead motion 2 Momentary The crosshead will move only if the button pressed and held Releasing the button will stop movement...

Страница 26: ...t a location along the column at which point the crosshead will stop moving Limit switches are located at the rear of the test stand column Adjust the switches positions by loosening repositioning and...

Страница 27: ...ay be overridden by pressing and holding UP or DOWN for two seconds Travel indication and limit switch operation is the same as in Basic Mode 6 4 Cycling Mode This mode cycles the crosshead between li...

Страница 28: ...unt of time in seconds for which the cross head stops at a limit during a cycle sequence When the crosshead has reached a limit a counter will be displayed shown as follows If the DWELL U and or DWELL...

Страница 29: ...to the number of cycles originally programmed 2 Resuming the cycle sequence Press UP or DOWN to resume Once the sequence has been completed the screen will revert to the number of cycles programmed or...

Страница 30: ...peed to maximum speed k Set crosshead speed to minimum speed l Enter travel limit mode m Enter manual mode n Transmit travel and force readings o Set crosshead speed to programmed speed p Request stan...

Страница 31: ...genTM TCD software which also utilizes the above commands The 09 1143 cable is needed to communicate between a Mark 10 gauge and the test stand The 09 1056 serial cable is needed to communicate betwee...

Страница 32: ...cal connections refer to Section 3 4 2 MESURgauge settings 1 Test Setup tab 1 Under Travel check the Enable box Under Reading Mode if Continuous Readings is se lected Readings per Sec defaults to 4 Th...

Страница 33: ...s guide 1 Set to automatic output of every sample 2 Disable Mitutoyo BCD output 4 Test stand settings 1 Set the baud rate to 115 200 2 Set the Control mode to Console 5 The Gauge Settings tab and all...

Страница 34: ...While in Operating Mode press STOP and menu simultaneously The display will appear as follows The Feature Activation Menu also includes a utility with which to reset the password To reset the passwor...

Страница 35: ...to Mark 10 or a distributor who will then provide a corresponding authorization code to activate the feature The process for entering the authorization code is as follows 1 The first digit of the req...

Страница 36: ...in the same fashion and will be active for the remaining time period 10 MAINTENANCE AND SERVICE The ESM301 should be operated in a dry and clean area Under these circumstances only a few periodic mai...

Страница 37: ...lt in a poten tially hazardous situation 10 3 Check for loosened components once per month 1 Remove the test sample from the test stand 2 Turn off power to the test stand and disconnect the power cord...

Страница 38: ...l input 80 240 VAC 50 60 Hz Fuse type 1 2 A 250V 3AG SLO BLO Weight without options 34 lbs 15 4 kg Included accessories Extension rod small hook medium hook 10 32 coupler compression plate force gauge...

Страница 39: ...User s Guide NOTES 38...

Страница 40: ...rt In addition to our standard line of products we can provide modifications and custom designs for OEM applications Our engineering team is eager to satisfy any special requirements Please contact us...