![Maritime G6100 Скачать руководство пользователя страница 102](http://html1.mh-extra.com/html/maritime/g6100/g6100_operation-manual_1727424102.webp)
Appendix
Page
102
of
110
MI6100-0013
System Type
Water Monitoring System
MI6100-0013
Task:
pH Sensor Replacement
Task
description:
This instruction identifies the replacement of the pH sensor. pH sensor
replacement must be carried out by a trained technician.
Difficulty 1-5
Overhaul Interval
Estimated Time Consumption
When necessary
5 min
Spare Parts
Tools
Part no:
Description:
Qty.
Item:
02344
pH sensor without electrode
Small flat headed screwdriver
17-19 mm Spanner
Instructions
Steps
1.
Take photos or notes on how the existing pH sensor
is installed. This will make it easy to install the
replacement sensor.
2.
Uninstall the old pH sensor using a small flat
headed screwdriver to disconnect the pH sensor
wiring inside the monitoring unit. Use the 17-19 mm
spanner to loosen the cable gland, then pull out the
cable.
3.
Install the replacement pH sensor in the same way
the old was installed or according to the electrical
drawing. If the replacement pH sensor does not have
the same wiring color as the old, then refer to the pH
sensor cable color codes in the conversion table
below.
Photos:
Notes: