background image

2

3

The "drip loop" is that part of the cord below the level of the receptacle or the
connector,if an extension cord is used,to prevent water traveling along the cord
and coming in contact with the receptacle. If the plug or receptacle does get
wet,DON'T unplug the cord.Disconnect the fuse or circuit breaker that supplies
power to the appliance.Then unplug and examine for presence of water in the
receptacle.

2.

Close supervision is necessary when any appliance is used by or near children.

3.

To avoid injury, do not contact moving parts or hot parts such as heaters,
reflectors, lamp bulbs, etc.

4.

Always unplug an appliance from an outlet when not in use, before putting
on or taking off parts, and before cleaning. Never yank cord to pull plug from
outlet. Grasp the plug and pull to disconnect.

5.

Do not use an appliance for other than intended use.The use of attachments
not recommended or sold by the appliance manufacturer may cause an
unsafe condition.

6.

Do not install or store the appliance where it will be exposed to the weather 
or to temperatures below freezing.

7.

Make sure an appliance mounted on a tank is securely installed before 
operating it.

8.

Read and observe all the important notices on the appliance.

9.

If an extension cord is necessary, a cord with a proper rating should be used.
A cord rated for less amperes or watts than the appliance rating may over-
heat. Care should be taken to arrange the cord so that it will not be tripped
over or pulled.

10. This appliance has polarized plugs (one blade is wider than the other).

As a safety feature, the plugs will fit in a polarized outlet only one way. If the
plug does not fit fully in the outlet, reverse the plug. If it still does not fit,
contact a qualified electrician. Never use with an extension cord unless plug
can be fully inserted. Do not attempt to defeat this safety feature.

SAVE THESE INSTRUCTIONS

IMPORTANT SAFEGUARDS

WARNING – To guard against injury, basic safety precautions should be
observed, including the following.

READ AND FOLLOW ALL 

SAFETY INSTRUCTIONS

DANGER – To avoid possible electric shock, special care should be taken in the use
of aquarium equipment. For each of the following situations, do not attempt repairs
yourself; return the appliance to an authorized service facility for service or discard
the appliance.

1. A. If the appliance falls into the water, DON'T reach for it! First unplug it and

then retrieve it.If electrical components of the appliance get wet,unplug the
appliance immediately.

B. If the appliance shows any sign of abnormal water leakage, immediately

unplug from the power source.

C. Carefully examine the appliance after installation. It should not be plugged

in if there is water on parts not intended to be wet.

D. Do not operate any appliance if it has a damaged cord or plug, or if it is mal-

functioning or if it is dropped or damaged
in any manner.

E. To avoid the possibility of the appliance

plug or receptacle getting wet, position
aquarium stand and tank to one side of a
wall mounted receptacle to prevent water
from dripping onto the receptacle or plug.
A "drip loop", shown in the Figure at right
should be arranged by the user for each
cord connecting an aquarium appliance 
to a receptacle.

AQUARIUM

TANK

EMPEROR

POWER
SUPPLY
CORDS

DRIP
LOOP

Содержание Emperor

Страница 1: ...tive in workmanship or materials Please return the unit together with proof of date of purchase to your local dealer or send unit postage paid to Marineland Aquarium Products 6100 Condor Drive Moorpark CA 93021 Damage or injuries resulting from negligence or misuse are not covered by these warranties Incidental or consequential damages are specifically excluded These warranties give you specific l...

Страница 2: ...than the other As a safety feature the plugs will fit in a polarized outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician Never use with an extension cord unless plug can be fully inserted Do not attempt to defeat this safety feature SAVE THESE INSTRUCTIONS IMPORTANT SAFEGUARDS WARNING To guard against injury bas...

Страница 3: ...on and relaxation for the entire family Fish As Pets Fish As Pets Think of your fish as pets and you ll agree they deserve the best care and attention you can provide They rely on you to keep their environment healthy A healthy aquarium is relatively easy to achieve and maintain but it will not happen by itself it depends on you In rivers lakes and oceans water is cleansed and filtered naturally I...

Страница 4: ...d PremiumActivated Carbon the highest grade there is The Refillable Media Containerscan hold an additional four ounces each of Black Diamond PremiumActivated Carbon White DiamondAmmonia Neutralizing Crystals or Diamond Blend White Diamond removes up to four times more deadly ammonia than other brands Diamond Blend combines the purifying power of Black Diamond with the protective ammonia adsorbing ...

Страница 5: ...ort its total weight An aquarium filled with water and gravel weighs approximately 10 12 pounds per gallon Always place an aquarium on a flat level surface never on the floor however Aquarium stands less than 12 wide should be anchored or tethered to a wall to provide stability Never place an aquarium in direct sunlight Full or even partial sunlight can cause excessive algae growth Handle your aqu...

Страница 6: ...T TS LIST KEY ITEM DESCRIPTION ITEM NO 1 Two Way Hinged CoverAssembly PR2105 2 Filter Box N A 3 Intake Strainer PR2110 4 IntakeTube PR2111 5 IntakeTube Extension PR2112 6 IntakeTube Extension Coupler PR2113 7 Flow Manifold Housing Cover PR2122 8 Flow Manifold Housing PR2125 9 Magnetic ImpellerAssembly Green PR2126 10 Spray BarAssembly PR2130 11 Spray Bar O Rings Pkg 4 PR2045 12 BIO WheelAssembly E...

Страница 7: ...IPTION ITEM NO 1 Two Way Hinged CoverAssembly PR2100 2 Filter Box N A 3 Intake Strainer PR2110 4 IntakeTube PR2111 5 IntakeTube Extension PR2112 6 IntakeTube Extension Coupler PR2113 7 Flow Manifold Housing PR2120 8 Magnetic ImpellerAssembly Natural PR2121 9 Flow Manifold Housing Cover PR2122 10 Spray BarAssembly PR2130 11 Spray Bar O Rings Pkg 4 PR2045 12 BIO WheelAssembly Emperor PR2140 13 BIO W...

Страница 8: ...Cartridges and Media Containers should always be positioned as shown Figure 1 As an alternative additional Emperor Cartridge s may be used in place of Media Container s STEP 4 INSTALL FILTER BOX Hang Filter Box in desired location on back of aquarium STEP 5 ASSEMBLE INTAKE TUBE AND STRAINER Slip Intake Strainer onto long end of Intake Tube Depending on aquarium size Intake Tube may be lengthened u...

Страница 9: ...ormance BIO Wheel rotation can be easily monitored via the BIO Wheel Indicator Window s Figure 6 IMPORTANT NEVER allow the Emperor System to operate without water at any time IMPORTANT To prevent wasteful overloading of Emperor Cartridge with fish food reduce water flow by simply pressing down on the Flow Control This will not affect BIO Wheel rotation or compromise biological filtration After fee...

Страница 10: ...C A U T I O N NEVER submerge Emperor in water NEVER attempt to remove Flow Control from Emperor NEVER use soaps detergents abrasives or any other cleaning agent on or around filter or aquarium ALWAYS unplug unit before performing maintenance of any kind MAINTENANCE MAINTENANCE Proper filter maintenance begins with frequent visual inspections to ensure normal system operation and non stressful cond...

Страница 11: ...be away from Filter Box and lift up for easy removal Figure 13 Push clips down Don t squeeze Figure 14 Cleaning Brush included Figure 15 Flow Manifold Impeller Assembly Manifold Cover Figure 16 Impeller Assembly should easily disengage from Flow Manifold 11 Using cold water wipe down the inside and outside surface of empty Filter Box with a clean cloth Using custom cleaning brush clean Impeller Su...

Страница 12: ...electrical cord momentarily then reconnecting to power source to restart the Impeller Check to see that Flow Manifold is seated firmly in Filter Box and that aquarium water is at correct level 1 2 3 4 from top of aquarium Inspect IntakeTube to ensure that it is not displaced from inside the Impeller Housing Collar Remove Flow Manifold and make certain that the Magnetic Impeller Assembly is free to...

Отзывы: