background image

43

42

EN

EN

STAGE 3 - FINISHING WORK

A. FINISHING WORK

External protection of the pool wall
Install studded membrane around the pool, embossing against the wall. The membrane 
must be cut around the skimmer. This membrane protects the pool wall against mechanical 
damage and ensures ventilation of moisture

Ensuring the stability of the pool construction
The inground pool is exposed to the pressure of the surrounding soil and it is therefore 
necessary to increase the external rigidity of the construction of the pool wall by concrete 
fill. If the pool is surrounded only by sand, soil or other unpaved material, there is a risk of 
slide and collapse of the pool.
The fill of the pool is done with a dry concrete mix. The approximate amount can be calcula-
ted from the data in the table in section D. Implementation of the excavation for sinking the 
ORLANDO swimming pool in the ground, multiplied by the depth of the sinking the pool 
in the ground in decimetres. Mix sand (preferably river) and SPC 325 cement in a ratio of 
5 shovels of sand to 1 shovel of cement. Mix the thoroughly dry mixture and then moisten 
so it can be held in a hand (does not crumble or slip between the fingers).
Fill around the perimeter of the pool in two levels. First about 5 cm below the level of the 
return nozzle together with concreting the bottom of the shaft for the skimmer. 
The next day, build a clay brick shaft around the skimmer and return nozzle (see Figure D-2). 
The top of the shaft must be about 1-2 cm above the top of the skimmer. Then pour the 
concrete mixture around the pool to the desired height. Also ensure the drainage the shaft 
space to prevent accumulation of the rainwater.
After the concrete has hardened, cut off the excess of the studded membrane.

Important note: 
During finishing work, take precautions so that dirt or stones from the area around the 
outer frame (e.g. from the interlocking paving layer) cannot enter the space between the 
pool wall and the studded membrane. E.g. by concrete fill, use of separating foil, etc. This 
dirt, if fitted between the studded membrane and the wall, may cause the wall to bulge and 
possibly damage the wall.

Note concerning the oval swimming pool
The technological procedure for filling the pool is the same as for the circular pool, but we 
recommend to do simple formwork in the excavation area for the side struts of the pool in 
order to avoid unnecessarily increasing of the consumption of concrete. After the concrete 
has hardened and the formwork has been removed, cover the remaining excavation space 
with soil and compact.

Note concerning the winterization of the swimming pool
When the pool is winterized, it is necessary to use an end cap to close the return nozzle hole 
and during this period keep the water level under the skimmer so that water cannot flow 
through it into the shaft.

Important note:

During the finishing works, the pool must be completely filled with water.

B. ADJUSTMENT AROUND THE POOL

Final finish of the area surrounding the pool depends on your requirements on its appearan-
ce. The basic requirement when choosing the final finish is safety. The selected paving must 
be anti-slip and frost-resistant. 
We recommend, for example, a layer of pebble (large stones of sieved sand), interlocking 
concrete pavement or artificial sandstone.

Important safety warning
A swimming pool, especially an inground swimming pool, is a permanent source 
of risk of injury or drowning of people and animals moving around it. Care shou-
ld be taken to prevent children and animals from entering the pool.
Access to the pool must be secured by appropriate means (fencing, etc.) to reduce 
the risk of drowning or injury of people, especially children.

Cover the shaft around the skimmer of the inground pools with a suitable board 
that meets the following requirements:
 a)  it is light enough to allow access to the skimmer lid for cleaning or connecting 

the pool vacuum cleaner, 

 b) it is strong enough for you to walk on it.

WARNING:

If the pool foil is to be replaced, the top frame of the pool will have to be removed.

Therefore, leave the top frame freely accessible when adjusting the surroundings of the pool. In the 

area around the top frame it is recommended to use a solution allowing free access to the top frame, 

e.g. removable interlocking pavement, see grey tile series in the figures below.

If the above warning is ignored, the replacement of the pool foil is possible only at the cost of damage 

to the surrounding area of the pool.

Содержание Orlando 10300001

Страница 1: ...BAZ N ORLANDO BAZ N ORLANDO PREMIUM Pokyny pro stavebn p pravu CZ SK DE PL EN HU...

Страница 2: ...v 4 A Zaji t n pot ebn ho materi lu 4 B V b r stanovi t pro stavbu baz nu 5 C P prava podkladu pro baz n 9 D Realizace v kopu pro zapu t n baz nu ORLANDO 9 ETAPA 2 mont baz nu a jeho uveden do provozu...

Страница 3: ...3 5m od st ny baz nu neum s ujte z suvku p vodu elektrick ho proudu ani erpadlo filtrace nebo jin elektrick za zen v souladu s SN 33 2000 7 702 Z suvka p vodu elektrick ho proudu pro nap jen venkovn h...

Страница 4: ...unce op r do panelu t m bude v sledek oh evu lep Pokud zvol te ikmou instalaci na st e e na zdi na plot na r mu apod orientujte panel na jih a jihoz pad Optim ln sklon panelu pro obdob pou v n kv ten...

Страница 5: ...ak odvedena do de ov ho svodu i kanalizace Zvl t se doporu uje e it omezen p stupu do prostoru baz nu Zapu t n baz n je toti pro d ti nebo zv ata snadno p stupn V z jmu bezpe nosti je nutno zabezpe it...

Страница 6: ...odm nky pro mont i de mont baz nov ch hadic Tento v kop ponechte odkryt tak aby bylo mo n prov st vlo en baz nov ch hadic do dre n n trubky p ed polo en m na dno v kopu Dren n trubku proto nezasyp vej...

Страница 7: ...ou b t p inou vyboulen a p padn ho po kozen st ny Pozn mka pro ov ln baz n Technologick postup obsyp n baz nu je stejn jako u kruhov ho baz nu pouze dopo ru ujeme jednoduch m zp sobem prov st bedn n v...

Страница 8: ...s cel m horn m r mem demontovatelnou P i prav okol baz nu dbejte na to aby byl zaji t n dostate n prostor pro de mont a mont horn ho r mu v etn jeho roubov ch spoj C NA Z V R Pou it a dr ba baz nu a p...

Страница 9: ...onem C16 20 d ve B20 s vyztu en m KARI s t p i horn m okraji desky viz N kres 2 D le it je aby KARI s zpev ovala celou plochu dnov desky a do kraje v etn oblasti pro um st n ikm ch vzp r Povrch dnov d...

Страница 10: ...arimex A ZABEZPE ENIE POTREBN HO MATERI LU V priebehu pr pravy podlo ia baz nu a jeho mont e bude potrebn ni ie uveden materi l ktor zabezpe uje z kazn k Pozn mka al potrebn materi l je uveden v asti...

Страница 11: ...ovn podklad by dobre pr stupn chr nen pred da om slne n mi l mi a pred mo n m zaplaven m vodou Vyva rujte sa in tal cie v jam ch acht ch a pod preto e je tu vysok riziko zaplavenia elektrick ho erpadl...

Страница 12: ...ry ako napr z sobn ky vody septiky kan ly a pod Umiestnenie baz nu pl nujte tak aby okolo baz nu zostal minim lny priestor pre manipu l ciu pri mont i a pre bud ce pou vanie baz nu min 1m b MIESTA KTO...

Страница 13: ...pod je d le it bra v vahu skuto n rozmery nie z kladn 2 V KOP V kop pre teleso baz nu by mal by uroben bu strojom alebo ru ne a tak aby rozmer p ty v kopu bol po obvode o najmenej 15 cm v ako je presn...

Страница 14: ...h bke zapustenia v decimetroch Zmie ajte piesok najlep ie rie ny a cement SPC 325 v pomere 5 lop t piesku na 1 lopatu cementu Dokonale za sucha pre mie ajte a potom zvlh ite tak aby zmes zovret v dla...

Страница 15: ...r a pou itie rie en umo uj ce vo n pr stup k horn mu r mu napr rozoberate n z mkov dla ba vi siv rada dla d c na obr zkoch ni ie Pri nere pektovan vy ie uveden ho upozornenia je v mena baz novej f lie...

Страница 16: ...vy ahovan v kov k ty v etk ch prav s visiacich s in tal ciou baz na V kop a plocha pre umiestnenie baz na mus by vyhotoven pod a rozmerov ch n rt kov staveniska pre konkr tny model baz na Tieto rozmer...

Страница 17: ...yer customer is responsible for all three 1 3 stages For your information here is a list of the best selling ORLANDO swimming pool accessories Swimming pool lining Swimming pool mat Swimming pool step...

Страница 18: ...0 3 0 3 SIFTED DREDGED SAND m3 to fill the corners 0 2 0 3 0 3 REQUIRED QUANTITY OF THE WATER m3 10 16 18 ORLANDO SWIMMING POOL Dimension 5 5m Dimension 3 7 x 5 5m SIFTED DREDGED SAND m3 to flat the u...

Страница 19: ...the better the heating result If you choose a slanted installation on a roof wall fence frame etc orient the panel south to south west The optimum inclination of the panel for the May September period...

Страница 20: ...essible for children or animals Due to their safety it is necessary to secure the surroundings of the pool before children and animals enter the pool C SUB BASE PREPARATION FOR THE POOL Preparation of...

Страница 21: ...r the assembly and disassembly of the pool hoses Leave this excavation exposed so that it is possible to insert the pool hoses into the drainage pipe before laying it on the bottom of the excavation D...

Страница 22: ...the wall Note concerning the oval swimming pool The technological procedure for filling the pool is the same as for the circular pool but we recommend to do simple formwork in the excavation area for...

Страница 23: ...to leave the paving adjacent to the entire top frame removable When adjusting the surrounding area of the pool make sure that there is sufficient space to remove and install the top frame including it...

Страница 24: ...ttom is concreted with 15 cm thick C16 20 concrete formerly B20 with KARI net reinforcement at the top edge of the slab see Drawing 2 It is important that the KARI net reinforces the entire surface of...

Страница 25: ...STANDORTS A SICHERUNG DES NOTWENDIGEN MATERIALS Im Verlauf der Vorbereitung des Untergrunds des Pools und seiner Montage wird das unten angegebene Material notwendig sein das vom Kunden gesichert wir...

Страница 26: ...sser gesch tzt werden Vermeiden Sie die Installation in Becken Sch chten u weil es hier die hohe Gefahr der berschwemmung der Elektropumpe mit Wasser besteht W hlen Sie einen Ort aus wo es hinter dem...

Страница 27: ...e befinden wie z B Wasserreservoire Faulgruben Kan le u befinden Planen Sie die Anbringung des Pools so dass um den Pool herum der Mindestraum f r die Manipulation bei der Montage und f r die k nftige...

Страница 28: ...n Bauanlagen z B der berdachung Podien u sind die tats chlichen Abmessungen nicht die Grundabmessungen in Betracht zu ziehen 2 AUSHUB Der Aushub f r den Poolk rper sollte entweder maschinell oder manu...

Страница 29: ...nd der Erdmasse oder mit einem anderen unbefestigten Material umgesch ttet wird droht die Gefahr des Rutsches der Umsch ttung und der Verwerfung des Pools F hren Sie die Umsch ttung des Pools mit dem...

Страница 30: ...des Pools m glich erh ht wird Den brigen Aushubraum versch tten Sie nach der Betonerh rtung und nach der Beseitigung der Schalung mit der Erdmasse und verdichten Sie sie Anmerkung f r die Einwinterung...

Страница 31: ...legung der grundlegenden Null Ebene des Bauwerks d h der H he auf die sich die H henkoten aller Gestaltungen im Zusammenhang mit der Installation des Pools beziehen von Bedeutung Der Aushub und die Fl...

Страница 32: ...se h rom szakaszb l ll 1 SZAKASZ a medence s tartoz kai hely nek kiv laszt sa s el k sz t se 2 SZAKASZ a medence fel p t se s zembe helyez se 3 SZAKASZ befejez munk latok s a medence k rnyezet nek ren...

Страница 33: ...ce fal t l m rt 3 5 m es t vols gon bel l ne helyezzen el elektromos ram h l zati csatlakoz aljzatot sem pedig m s elektromos k sz l ket a SN332000 7 702 sz szabv ny el r saival sszhangban Az elektrom...

Страница 34: ...nn l jobbak lesznek Ha ferde s kban t rt n telep t st v laszt tet re falra ker t sre keretre stb szerelve a napelemes panelt t jolja d li d lny ugati ir nyba A m just l szeptemberig tart id szakban ha...

Страница 35: ...y a vizet elvezess k az es csatorn ba vagy a csatornah l zatba K l n javasoljuk hogy korl tozza a medence ter let re t rt n hozz f r st A f ldbe s llyesztett medence ugyanis gyermekek vagy llatok r sz...

Страница 36: ...tsonamedencecs vekbe skiszerel s hez Eztaz rkothagyjanyitottanolym don hogyamedencecs veketbelelehessenhelyeznia dr ncs beaz rokalj nt rt n elhelyez sel tt Adr ncs vetez rtnemszabadaz rokban betakarni...

Страница 37: ...s nek a technol giai elj r sa ugyanaz mint a k r alak me denc n l itt csup n azt javasoljuk m g hogy a g d rben k sz tsen egyszer zsaluzatot a medence oldals t maszai r sz re annak rdek ben hogy feles...

Страница 38: ...talajcsemp t oly m don kell be p teni hogy a csempe leszerelhet legyen A medence k rny k nek a rendez s n l gyeljen arra hogy elegend helyet biztos tson a medence fels keret nek a le s felszerel s hez...

Страница 39: ...s g beton felhaszn l s val amelyet a lemez fels r sz ben elhelyezett KARI ac lh l val er s t nk meg l sd a 2 es Rajzot Fontos hogy a KARI ac lh l meger s tse a fen klemez teljes fel let t eg szen a le...

Страница 40: ...nia podk adu basenu i jego monta u niezb dny b dzie poni szy materia kt ry zapewnia klient Uwaga Inne niezb dne materia y podano w cz ci D Wykonanie wykopu do wpuszczenia basenu ORLANDO Uwaga Nale y p...

Страница 41: ...hronione przed deszczem promieniami s o ca i przed potencjalnym zalaniem wod Nale y unika instalacji w zbiornikach studniach itp poniewa istnieje du e ryzyko zalania pompy elektrycznej wod Nale y wybr...

Страница 42: ...e np zbiorniki wodne szamba kana y itp Lokalizacj basenu nale y zaplanowa tak eby wok basen pozosta minimalny obszar do manipulacji podczas monta u i przysz ego u ytkowania basenu min 1 m b MIEJSCA KT...

Страница 43: ...tawowe 2 WYKOP Wykop na korpus basenu powinien zosta wykonany albo maszynowo albo r cznie tak eby wymiary podstawy wykopu w obwodzie by y co najmniej o 15 cm wi ksze ni dok ad ne wymiary basenu patrz...

Страница 44: ...no y przez dane o g boko ci wpuszczenia w decymetrach Zmiesza piasek najlepiej rzeczny i cement SPC 325 w proporcji 5 opat pasku na 1 opat cementu Bardzo dok adnie przemiesza a p niej zwil y tak eby m...

Страница 45: ...zwi za umo liwiaj cych swobodny dost p do g rnej ramy np atwa w demonta u kostka brukowa patrz szara linia kostki na poni szych rysunkach W przypadku nieprzestrzegania powy szego ostrze enia wymiana f...

Страница 46: ...o kt rej odnosi si b d rz dne wysoko ci wszystkich zmian zwi zanych z instalacj basenu Wykop i powierzchnia do umieszczenia basenu musi by wykonana zgodnie ze szkicami wymi ar w placu budowy dla konkr...

Страница 47: ...rubo ci 5 cm 3 betonowa p yta na dno o grubo ci 15 cm 4 zbrojenie p yty na dno siatka kari 6 mm lub 8 mm oczka 15x15 cm 5 podk adka z geow kniny 6 dolna listwa 7 folia i ciana basenu 8 folia kube kowa...

Отзывы: