Appendix A 

– NMEA 2000 Interfacing 

Page A1 

 

Appendix A 

– NMEA 2000

®

 Interfacing 

 

TMP100 NMEA 2000

®

 Periodic Data Transmitted PGNs 

 

PGN 130310 

– Environmental Parameters (not recommended for new designs; included 

for backward compatibility) 

The TMP100 uses this PGN to provide a regular transmission of water temperature and 
outside air temperature. The factory default for periodic transmission rate is twice per second. 
The transmission of this PGN can be disabled (see PGN 126208 

– NMEA Request Group 

Function 

– Transmission Periodic Rate).  

 Field 1:  SID 

– The sequence identifier field is used to tie related PGNs together. For 

example, the TMP100 will transmit identical SIDs for 130310 (Environmental 
Parameters) and 130312 (Temperature) to indicate that the readings are linked 
together (i.e., the data from each PGN was taken at the same time although they are 
reported at slightly different times). 

 

2:  Water  Temperature 

–  This  field  is  used  to  indicate  water  temperature  in  units  of 

0.01°C. 

 

3:  Outside Ambient Air Temperature 

– This field is used to indicate the outside ambient 

air temperature in units of 0.01°C. 

 

4:  Atmospheric Pressure 

– This field is filled by the TMP100 with a value indicating “data 

not available”. 

 

5:  Reserved bits 

– The TMP100 sets all bits in this field to a value of “1”. 

 
PGN 130311 

– Environmental Parameters (not recommended for new designs; included 

for backward compatibility) 

The TMP100 uses this PGN to provide a regular transmission of outside temperature, relative 
humidity, and atmospheric pressure. The factory default for periodic transmission rate is twice 
per second. The transmission of this PGN can be disabled (see PGN 126208 

– NMEA 

Request Group Function 

– Transmission Periodic Rate).  

 Field 1:  SID 

– The sequence identifier field is used to tie related PGNs together. For 

example, the TMP100 will transmit identical SIDs for 130311 (Environmental 
Parameters) and 130312 (Temperature) to indicate that the readings are linked 
together (i.e., the data from each PGN was taken at the same time although they are 
reported at slightly different times). 

 

2:  Temperature Instance 

– The TMP100 sets this field to indicate the type of 

temperature reading. The value of this field depends on the setting of the 
temperature source for each channel. This value can be any of Sea Temperature, 
Outside Temperature, Inside Temperature, Engine Room Temperature, or Main 
Cabin Temperature. 

 

3:  Humidity Instance 

– The TMP100 sets this field to a value indicating “data not 

available”. 

 

4:  Temperature 

– This field is used to indicate the temperature, whose source is 

specified in field 2, in units of 0.01°C. 

 

5:  Humidity 

– The TMP100 sets this field to a value indicating “data not available”. 

 

6:  Atmospheric Pressure 

– The TMP100 sets this field to a value indicating “data not 

available”. 

Содержание TMP100

Страница 1: ...Page i TMP100 Temperature Module User s Manual Revision 1 2 Copyright 2015 Maretron LLP All Rights Reserved Maretron LLP 9014 N 23rd Ave 10 Phoenix AZ 85021 7850 http www maretron com Maretron Manual...

Страница 2: ...tion of red Loctite threadlocking compound and cleaning agents containing acetone Typographical corrections 1 2 Updated specification table added 130316 PGN Formatting and typographical changes Added...

Страница 3: ...nnections 7 2 5 Configuring the TMP100 7 2 5 1 Channel 0 1 Source 7 2 5 2 Channel 2 5 Source 7 2 5 3 Channel 0 5 Instance 8 2 5 4 Channel 0 5 Label 8 2 5 5 Device Label 8 2 5 6 Advanced Configuration...

Страница 4: ...TMP100 User s Manual Page iv Revision 1 2 Table of Appendices Appendix A NMEA 2000 Interfacing A1...

Страница 5: ...e marine environment However no piece of marine electronic equipment can function properly unless installed configured and maintained in the correct manner Please read carefully and follow these instr...

Страница 6: ...n 2 2 3 Mount the TMP100 Section 2 3 4 Connect the TMP100 Section 2 4 5 Configure the TMP100 Section 2 5 2 Installation 2 1 Unpacking the Box When unpacking the box containing the Maretron TMP100 you...

Страница 7: ...Connection The NMEA 2000 connector can be found on the side of the enclosure The NMEA 2000 connector is a round five pin male connector see Figure 2 You connect the TMP100 to an NMEA 2000 network usin...

Страница 8: ...T1 Exhaust Gas Temperature Probe 1 positive terminal 4 T1 Exhaust Gas Temperature Probe 1 negative terminal 5 T2 Temperature Probe 2 positive terminal 6 T2 Temperature Probe 2 negative terminal 7 T3 T...

Страница 9: ...sure to connect the red wire from the EGT probe to the negative terminal and the yellow wire from the EGT probe to the positive terminal This figure shows the connection of the exhaust gas temperatur...

Страница 10: ...l 5 is similar Figure 4 Ring Under Bolt Ambient Air or Immersion Temperature Probe Connection Diagram 2 4 2 2 1 Cable Extension If the cable on the thermistor type probe is not long enough to reach fr...

Страница 11: ...on IPG100 Internet Protocol Gateway Please refer to the user s manual for the configuration tool you are using for details on how to configure the TMP100 with that product 2 5 1 Channel 0 1 Source You...

Страница 12: ...toring software or display as well as when alerts are generated 2 5 5 Device Label This entry allows you to assign a text label to the device This label is visible in Maretron analysis and display pro...

Страница 13: ...ed operation of the Maretron TMP100 follow the troubleshooting procedures in this section to remedy simple problems If these steps do not solve your problem please contact Maretron Technical Support r...

Страница 14: ...tandard Level A Maritime Navigation and Radiocommunication Equipment Systems IEC 61162 3 Maritime Navigation and Radiocommunication Equipment Systems IEC 60945 FCC and CE Mark Electromagnetic Compatib...

Страница 15: ...ity 93 RH 40 C per IEC60945 8 2 Vibration 2 13 2Hz 1mm 13 2 100Hz 7m s2 per IEC 60945 8 7 Solar Radiation Ultraviolet B A Visible and Infrared per IEC 60945 8 10 Corrosion Salt Mist 4 times 7 days 40...

Страница 16: ...n 1 2 7 Installation Template Please check the dimensions before using the following diagram as a template for drilling the mounting holes because the printing process may have distorted the dimension...

Страница 17: ...ETRON BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES DAMAGES FOR LOSS OF USE LOSS OF ANTICIPATED PROFITS OR SAVINGS OR ANY OTHER LOSS INCURRED BECAUSE OF INTERRUPTION OF SERVICE IN NO EVENT SHALL M...

Страница 18: ...TMP100 User s Manual Page 14 Revision 1 2 This page intentionally left blank...

Страница 19: ...of 1 PGN 130311 Environmental Parameters not recommended for new designs included for backward compatibility The TMP100 uses this PGN to provide a regular transmission of outside temperature relative...

Страница 20: ...Point Temperature Apparent Wind Chill Temperature Theoretical Wind Chill Temperature Heat Index Temperature Freezer Temperature Exhaust Gas Temperature and User Defined 129 144 4 Actual Temperature Th...

Страница 21: ...field is used to tie related PGNs together i e the data from each PGN was taken at the same time although they are reported at slightly different times 5 Temperature Instance The TMP100 sets this fiel...

Отзывы: