background image

6

Mareli Systems

Automatic cleaning 

mechanism for the 

turbulators 

(OPTIONAL)

m m

m

Φ6 Φ8

m

6

86

m

m

m

m

m

8

6

m

m

m

m

 

Display

Manual cleaning 

mechanism for the 

turbulators

Combustion 

Chamber 

Igniter

Automatic cleaning 

Mechanism for the 

brazier

Ashtray 

Pellet Bunker 

Содержание ECOSTAR AUTO 50

Страница 1: ...Mareli Systems ECOSTAR AUTO 50 KW Pellet BOILER Assembly and exploitation manual...

Страница 2: ...ouroromissions Anyinterventionorreplacementthatismadebyunauthorizedpeopleorusingnonoriginalspare partsfortheproductcanberiskyfortheuserandreleasethecompanyfromallliability Mostsurfacesoftheboilerareex...

Страница 3: ...ocess no agglutinate agents glues resins and others are added Actual ly the integrity of the pellets is guaranteed by the lignite a natural ingredient contained in the wood itself While the wood has a...

Страница 4: ...4 Mareli Systems 1615 808 861 808 861 448...

Страница 5: ...5 Mareli Systems 1 0 0 0 0 220 318 G 1 1 4 G 1 1 4 G 1 1 4 167 1053 448 168 298...

Страница 6: ...ing mechanism for the turbulators OPTIONAL m m m m 6 8 m 6 86 m m m m m 8 6 m m m m Display Manual cleaning mechanism for the turbulators Combustion Chamber Igniter Automatic cleaning Mechanism for th...

Страница 7: ...e wall Minimum distances from the wall to the boiler should be at least 400 mm The mini mum space in front of the fireplace should be 1500 mm The minimal distance of the boiler from combustion materia...

Страница 8: ...8 Mareli Systems CHECK ITEMS BEFORE INSTALLATION Chimney exit Chimney Connection to chimney Connection to the boiler Security distances The floor Inlet air The chimney revision door...

Страница 9: ...pped with water serpentine and a solar panel For economy and efficiency of the system and a constant availability of cheap hot water a qualified assembly of the automatic shifter controlling the ther...

Страница 10: ...ontal sections Direction shift is done by using knee joints with a max angle of 45 For heating devices equipped with a smoke ventilator i e all of the MARELI boilers the follow ing instructions must b...

Страница 11: ...mal mechanical wear and to the heat coming from the combustion products and condensation To be kept away from flammable materials The recommended chimney draft at work from 12 20 Pa 45 5 m MAX MAX Att...

Страница 12: ...Systems 3 4Typesofconnectiontothechimney Chimney exit Moisture channel Chimney Thermal insulation External wall Connection to chimney Flue gas connection T connection The chimney revision door Heat g...

Страница 13: ...hould be done only when cold The cleaning of the combustion chamber must be carried out daily For this purpose make sure the fireplace has ceased operation and is completely cold Pull up the combustio...

Страница 14: ...14 Mareli Systems CLEANING THE PELLET TANK ECOSTAR AUTO...

Страница 15: ...15 Mareli Systems Left inspection door Right inspection door ECOSTAR AUTO ECOSTAR AUTO...

Страница 16: ...16 Mareli Systems 230V 50HZ PUMP 2 PUMP COLD WATER HOT WATER OUTLET SAFETY VALVE EXHAUST FAN...

Страница 17: ...17 Mareli Systems IT IS MANDATORY THAT AT EACH EMPTYING OF THE ASH CONTAIN ERS THE COMBUSTION BOX IS ALSO CLEANED 1 ECOSTAR AUTO...

Страница 18: ...18 Mareli Systems EMPTY THE FIRST ASH CONTAINER 2 ECOSTAR AUTO...

Страница 19: ...19 Mareli Systems REMOVE THE 2 OTHER ASH CONTAINERS FROM THE SIDES 3 ECOSTAR AUTO...

Страница 20: ...20 Mareli Systems EMPTY THE 2 SIDE ASH CONTAINERS ECOSTAR AUTO...

Страница 21: ...f the fireplace may fall hot burning particles as hot ash and small particles burning coal which could lead to a fire in the heated room It is therefore necessary that the product always works with a...

Страница 22: ...ystems K400 TOUCH SCREEN DISPLAY 1 HOMEPAGE Errors Code Date Time HOMEPAGE 1 2 Main Temperature Main Thermostat Functioning State ON OFF Settings Display Info Chrono 11 24 Fri 14 Oct 2016 65 21 C IGNI...

Страница 23: ...3 Auger Aux1 Pump 1 Aux1 Pump 2 Aux3 HOMEPAGE 2 2 L6 L7 L8 System activity LEDS The Quick visualization of the system main function is accessed through a vertical swipe to the top side of the screen S...

Страница 24: ...Oct 2016 65 21 C IGNITION Er 01 Er10 10 50 11 20 11 20 11 20 11 20 Er 53 Er 53 Er 53 Er 53 Error List By clicking on you can see the errors stored by date time and description Scroll to unlock Error 1...

Страница 25: ...nu 12 18 Ven 14 Ott 2016 28 22 C RECUPERO ACCENSIONE Er52 12 18 Ven 14 Ott 2016 28 22 C RECUPERO ACCENSIONE Er52 COMBUSTION HEATING REMOTE PANEL MANUAL LOADING RESET SERVICE Setting Menu 11 24 Ven 14...

Страница 26: ...3 15 04 30 09 00 11 30 21 15 23 30 Start Stop 01 02 04 03 05 15 30 00 45 15 02 03 05 04 06 00 15 45 30 00 To edit the time slots press on the corresponding Frame Time Scroll Up or Down to change the S...

Страница 27: ...ontrol panel is 17 and subsequently the others according to the number provided by the system Control panel restart this function allows the control panel to be restarted Sound this function allows th...

Страница 28: ...V IN 7 RS232 47 46 49 48 51 50 52 54 53 47 46 49 48 51 50 52 54 53 AUX 3 COM N O GND S9 GND S10 S11 Vc V IN 9 IN 10 11 POWER CABLE PROTECTION AGAINST OVERHEATING OFWATER DISPLAY RELAY FOR THE CLEANIN...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Отзывы: