background image

2

Mareli Systems

Observing the prescriptions of the present manual is in the user’s favour and is one of 

the warranty conditions. Compliance with this instruction is in the interest of the con-

sumer and one of the warranty terms.

•  This appliance is not intended for use by people (including children) with limited physical, sen-

sory or mental abilities or lack of experience and knowledge. The installation must be performed 

by a qualified expert in the field of heating installations or authorized by “Marelli Systems’ service. 

The place and way of connecting the boiler should be selected carefully in accord with the safety 

instructions. Install away from flammable objects!

•  Before starting any operation, the user must read and fully understand the contents of this instruc-

tion manual. Incorrect setup may cause hazardous conditions and / or incorrect function of the boil;

•  Do not wash the boiler with water. Water can get inside the fireplace and damage the electronics 

and cause an electric shock;

•  Do not put clothes to dry on the boiler. Any clothes hangers and other objects must be located 

within a reasonable distance from the fireplace. Fire hazard;

•  The user is fully responsible for the proper use of the product which exempts the company from 

liability of any users errors or misbehaviour or omissions;

•  Any intervention or replacement that is made by unauthorized people or using non original spare 

parts for the product can be risky for the user and release the company from all liability;

•  Most surfaces of the boiler are extremely hot (the door handle, glass, flue pipe, etc.). Avoid contact 

with these parts before assuring yourself that you us temperature resistant gloves as well as suitable 

temperature resistant instruments;

•  Under no circumstances should the fire be ignited with the door open or broken glass;

•  The product must be electrically connected to a system equipped with an effective earth conduc-

tor. (Must be grounded);

•  Turn off the boiler in case of failure or malfunction;

•  All unburned pellets in the burner after each unsuccessful attempt ignition must be removed 

before a new ignition;

•  When installing the product all fire safety requirements must be respected

If there is a fire in the flue pipe, extinguish the boiler, disconnect the power cord and never open the 

door. Call competent authorized service technicians;

•  Do not light the boiler with flammable materials if the ignition system failed;

•  Periodically check and clean the smoke outlet ducts of the boiler (connection to the flue pipe);

•  Pellet boiler is not a cooker;

•  Always keep the cover closed;

SAFE DISTANCES:

When installing the product a safe distance of at least 600 mm must be respected. This 

distance applies to the product located near materials of B or C flammability level. The 

safe distance is doubled if the product is close to materials of C3 combustion level.

INSTRUCTIONS FOR SECURITY:

Содержание ECOSTAR AUTO 50

Страница 1: ...Mareli Systems ECOSTAR AUTO 50 KW Pellet BOILER Assembly and exploitation manual...

Страница 2: ...ouroromissions Anyinterventionorreplacementthatismadebyunauthorizedpeopleorusingnonoriginalspare partsfortheproductcanberiskyfortheuserandreleasethecompanyfromallliability Mostsurfacesoftheboilerareex...

Страница 3: ...ocess no agglutinate agents glues resins and others are added Actual ly the integrity of the pellets is guaranteed by the lignite a natural ingredient contained in the wood itself While the wood has a...

Страница 4: ...4 Mareli Systems 1615 808 861 808 861 448...

Страница 5: ...5 Mareli Systems 1 0 0 0 0 220 318 G 1 1 4 G 1 1 4 G 1 1 4 167 1053 448 168 298...

Страница 6: ...ing mechanism for the turbulators OPTIONAL m m m m 6 8 m 6 86 m m m m m 8 6 m m m m Display Manual cleaning mechanism for the turbulators Combustion Chamber Igniter Automatic cleaning Mechanism for th...

Страница 7: ...e wall Minimum distances from the wall to the boiler should be at least 400 mm The mini mum space in front of the fireplace should be 1500 mm The minimal distance of the boiler from combustion materia...

Страница 8: ...8 Mareli Systems CHECK ITEMS BEFORE INSTALLATION Chimney exit Chimney Connection to chimney Connection to the boiler Security distances The floor Inlet air The chimney revision door...

Страница 9: ...pped with water serpentine and a solar panel For economy and efficiency of the system and a constant availability of cheap hot water a qualified assembly of the automatic shifter controlling the ther...

Страница 10: ...ontal sections Direction shift is done by using knee joints with a max angle of 45 For heating devices equipped with a smoke ventilator i e all of the MARELI boilers the follow ing instructions must b...

Страница 11: ...mal mechanical wear and to the heat coming from the combustion products and condensation To be kept away from flammable materials The recommended chimney draft at work from 12 20 Pa 45 5 m MAX MAX Att...

Страница 12: ...Systems 3 4Typesofconnectiontothechimney Chimney exit Moisture channel Chimney Thermal insulation External wall Connection to chimney Flue gas connection T connection The chimney revision door Heat g...

Страница 13: ...hould be done only when cold The cleaning of the combustion chamber must be carried out daily For this purpose make sure the fireplace has ceased operation and is completely cold Pull up the combustio...

Страница 14: ...14 Mareli Systems CLEANING THE PELLET TANK ECOSTAR AUTO...

Страница 15: ...15 Mareli Systems Left inspection door Right inspection door ECOSTAR AUTO ECOSTAR AUTO...

Страница 16: ...16 Mareli Systems 230V 50HZ PUMP 2 PUMP COLD WATER HOT WATER OUTLET SAFETY VALVE EXHAUST FAN...

Страница 17: ...17 Mareli Systems IT IS MANDATORY THAT AT EACH EMPTYING OF THE ASH CONTAIN ERS THE COMBUSTION BOX IS ALSO CLEANED 1 ECOSTAR AUTO...

Страница 18: ...18 Mareli Systems EMPTY THE FIRST ASH CONTAINER 2 ECOSTAR AUTO...

Страница 19: ...19 Mareli Systems REMOVE THE 2 OTHER ASH CONTAINERS FROM THE SIDES 3 ECOSTAR AUTO...

Страница 20: ...20 Mareli Systems EMPTY THE 2 SIDE ASH CONTAINERS ECOSTAR AUTO...

Страница 21: ...f the fireplace may fall hot burning particles as hot ash and small particles burning coal which could lead to a fire in the heated room It is therefore necessary that the product always works with a...

Страница 22: ...ystems K400 TOUCH SCREEN DISPLAY 1 HOMEPAGE Errors Code Date Time HOMEPAGE 1 2 Main Temperature Main Thermostat Functioning State ON OFF Settings Display Info Chrono 11 24 Fri 14 Oct 2016 65 21 C IGNI...

Страница 23: ...3 Auger Aux1 Pump 1 Aux1 Pump 2 Aux3 HOMEPAGE 2 2 L6 L7 L8 System activity LEDS The Quick visualization of the system main function is accessed through a vertical swipe to the top side of the screen S...

Страница 24: ...Oct 2016 65 21 C IGNITION Er 01 Er10 10 50 11 20 11 20 11 20 11 20 Er 53 Er 53 Er 53 Er 53 Error List By clicking on you can see the errors stored by date time and description Scroll to unlock Error 1...

Страница 25: ...nu 12 18 Ven 14 Ott 2016 28 22 C RECUPERO ACCENSIONE Er52 12 18 Ven 14 Ott 2016 28 22 C RECUPERO ACCENSIONE Er52 COMBUSTION HEATING REMOTE PANEL MANUAL LOADING RESET SERVICE Setting Menu 11 24 Ven 14...

Страница 26: ...3 15 04 30 09 00 11 30 21 15 23 30 Start Stop 01 02 04 03 05 15 30 00 45 15 02 03 05 04 06 00 15 45 30 00 To edit the time slots press on the corresponding Frame Time Scroll Up or Down to change the S...

Страница 27: ...ontrol panel is 17 and subsequently the others according to the number provided by the system Control panel restart this function allows the control panel to be restarted Sound this function allows th...

Страница 28: ...V IN 7 RS232 47 46 49 48 51 50 52 54 53 47 46 49 48 51 50 52 54 53 AUX 3 COM N O GND S9 GND S10 S11 Vc V IN 9 IN 10 11 POWER CABLE PROTECTION AGAINST OVERHEATING OFWATER DISPLAY RELAY FOR THE CLEANIN...

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics Mareli Systems MareliSystems I...

Отзывы: