The automated pellet burner is a part of the system and may utilize the following types of fuel:

• 

Wooden pellets in 6 and 8 mm in size, class A;

The automated pellet burner is a compact module structure consisting of the following components:
• 

Burning chamber, which provides conditions for optimal burning process and is manufactured of high 

quality alloyed steel.

• 

Automated mechanical cleaning.

• 

Burning chamber grid, easy to dismount, allowing removal of ash residue.

• 

Full air duct, which ensures even supply of air for combustion and cooling the burner elements.

• 

Electric heater to spark the fuel. 

• 

Fan supplying air for combustion.

• 

Photo sensor to monitor the combustion process. 

Emergency temperature sensor to prevent from “backfire” in the pipe of the main pellet feeding module, which 

automatically cuts off the fuel supply.

The equipment operation process is monitored by the controller. It controls the ignition and combustion pro-

cesses and they are monitored by the photo sensor and the temperature sensor. In case of two failed attempts 

for ignition the burner shuts down.

A temperature sensor is installed in the burner to prevent reverse fuel combustion, (‘backfire’). In case of this, 

the controller will shut down the burner, going to emergency mode.

In case of the above situation, unplug the controller from power supply, take all safety measures such as pre-

venting fire and thermal shock, then carefully clean the burner. It is advisable to call an authorized service 

technician to establish whether the equipment is safe. There is a risk of thermostat damage and melting the 

flexible pellet feeding tube. To prevent backfire, it should be checked if the burner is cleaned and if the settings 

are proper. 

If during operation the connector is removed or not well adjusted, the burner shuts down automatically.

The boiler consists of the following components:

• 

The heat exchanger is a welded construction made of steel sheet material. In the front lower part there 

is a furnace chamber and underneath the ash container is placed. The heat exchanger is compact and 

constructively based on a triple-motion principle, which enables an optimal heat exchange and high 

efficiency;

• 

The ceramic elements mounted in the combustion chamber ensure an optimal burning process and a 

complete combustion of the fuel; 

• 

The ash tray is situated on the bottom of the combustion chamber. There the remaining ash is gathered 

and it allows for easy cleaning of the device;

• 

The incoming and outgoing connector for feeding and the unloading water are situated in the rear part of 

the boiler and represent two terminals with an outer thread G1½ through which the device is connected 

to the heating system;

• 

The drainage hole is a terminal with a G1/2 thread upon which an unloading valve is to be mounted;

• 

The funnel (with an outer diameter of F145) is situated in the upper rear part of the boiler, and leads off 

the smoke gasses through the chimney;

• 

The steel heat exchanger is isolated with mineral isolation which reduces the environmental thermal 

losses;

• 

The outer decorative walls are made of steel sheet iron and are worked with a high quality colour layer;

Содержание CBM 45

Страница 1: ...Pellet Water Boiler CBM 45 Assembly and exploitation manual Mareli Systems...

Страница 2: ...ion and exploitation manual of the pellet bunker if the device is provided with one The non fulfillment of prescriptions and violation of active regulations and directives may lead to damage and unexp...

Страница 3: ...ed service technician to establish whether the equipment is safe There is a risk of thermostat damage and melting the flexible pellet feeding tube To prevent backfire it should be checked if the burne...

Страница 4: ...oiler needs to be well levelled thus ensuring its proper venting Attention Fire risk due to flammable materials and liquids Make sure no flammable materials and or liquids are in the vicinity of the h...

Страница 5: ...pressure of the water must be equal to 2 bar the maximum to 6 0 bar There must be an available capacity of at least 11 l min Connect the safety heat exchanger according to the hydraulic chart with a...

Страница 6: ...installation for user Attention Hazard to life in case of non observation of the safety prescriptions Functions of Individual Elements Strong fanning can lead to flame extinguishing due to excessive...

Страница 7: ...a temperature of around 90 is reached Remove the tar from the floor and the heating surfaces by the cleaning spade Boiler Inspection and Maintenance Why is regular maintenance important These are the...

Страница 8: ...an be monitored on the display Warranty The manufacturer guarantees correct and reliable operation of the product only when requirements for in stallation and operation are met according to the manual...

Страница 9: ...tat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of revo...

Страница 10: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Страница 11: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Страница 12: ...12 Mareli Systems WIRING DIAGRAM SMB 50...

Страница 13: ...13 Mareli Systems WIRING DIAGRAM PB 40 52...

Страница 14: ...14 Mareli Systems NOTES...

Страница 15: ......

Страница 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics MareliSystems IndustrialZone S...

Отзывы: