Mareli Systems

Description

 

Code 

Sond

Hi

Clean

Port

Ignition 

block

Cleaning on

Link Error

Anomaly of the probes checking, during Check Up phase.
Room temperature greater than 99 °C.
This message notifies that the planned hours of functioning are reached.
Door Open.

The message appears if the system is turned off during Ignition (after Preload) not manually: 

the system will stop only when it goes in Run Mode.

Periodical Cleaning in progress.
No communication between motherboard and keyboard

MESSAGES

Exhaust T. [°C]

  - Exhaust temperature;

Room T. [°C]

  - Local room temperature; it is visible only if;

Buffer T. [°C]

 - Buffer Temperature;

Pressure [mbar]

 - Water pressure;

Air Flux

 - Air flow;

Fan Speed [rpm]

 - Exhaust fan speed;

Auger [s]

 - Auger work time;

Recipe [nr]

 - Combustion recipe set;

Product Code: 510

 - Product code;

VISUALIZATIONS

USER MENU 1

Combustion Management

Power - 

In this menu is possible to modify the combustion power of the system. It can be set in automatic or 

manual modality . In the first case the system chooses the combustion power. In the second case the user selects 

the desired power. On the left side of the display are signalled the combustion modality (A=automatic combustion, 

M=manual combustion) and the working power of the system.

Recipe 

- Menu to select the combustion recipe. The maximum value is the number of recipes visible to the user. 

Auger Calibration - 

It allows to modify the value set in firm of Auger’s speed or On times. The values are in the 

range – 7 ÷ 7. The firm’s value is 0.

Fan Calibration - 

It allows to modify the value set in firm of Combustion Fan’s speed. The values are in the range 

– 7 ÷ 7. The firm’s value is 0.

Heating Management
Boiler thermostat 

- Menu to change the value of the boiler thermostat .

Buffer thermostat - 

Menu to change the value of the Buffer Thermostat.

Room Thermostat - 

This Menu allows to modify the Local Room Thermostat’s value. It is visible only if the ambient 

probe is select.

Summer-Winter -

 Menu that allows the selection Summer-Winter.

Manual Load

The procedure activates the pellet manual loading with activation in continue modality of the Auger engine. The 

loading is stopped automatically after 600 seconds. The system must be OFF for the function can be activated.

Cleaning Reset

 

Menu to reset the ‘System Maintenance 2’ function.

Содержание CBM 45

Страница 1: ...Pellet Water Boiler CBM 45 Assembly and exploitation manual Mareli Systems...

Страница 2: ...ion and exploitation manual of the pellet bunker if the device is provided with one The non fulfillment of prescriptions and violation of active regulations and directives may lead to damage and unexp...

Страница 3: ...ed service technician to establish whether the equipment is safe There is a risk of thermostat damage and melting the flexible pellet feeding tube To prevent backfire it should be checked if the burne...

Страница 4: ...oiler needs to be well levelled thus ensuring its proper venting Attention Fire risk due to flammable materials and liquids Make sure no flammable materials and or liquids are in the vicinity of the h...

Страница 5: ...pressure of the water must be equal to 2 bar the maximum to 6 0 bar There must be an available capacity of at least 11 l min Connect the safety heat exchanger according to the hydraulic chart with a...

Страница 6: ...installation for user Attention Hazard to life in case of non observation of the safety prescriptions Functions of Individual Elements Strong fanning can lead to flame extinguishing due to excessive...

Страница 7: ...a temperature of around 90 is reached Remove the tar from the floor and the heating surfaces by the cleaning spade Boiler Inspection and Maintenance Why is regular maintenance important These are the...

Страница 8: ...an be monitored on the display Warranty The manufacturer guarantees correct and reliable operation of the product only when requirements for in stallation and operation are met according to the manual...

Страница 9: ...tat open flame return from the brazier Er07 Encoder Error The error may occur due to lack signal from Encoder Er08 Encoder Error The error can occur due to problems of adjustment of the number of revo...

Страница 10: ...ond case the user selects the desired power On the left side of the display are signalled the combustion modality A automatic combustion M manual combustion and the working power of the system Recipe...

Страница 11: ...day at the desired time Ex 6 30 The system turns on at 20 30 on Tuesday and turns off at 6 30 on Wednesday Weekly The programs are the same for all days of the week Week end Choose between Monday Fri...

Страница 12: ...12 Mareli Systems WIRING DIAGRAM SMB 50...

Страница 13: ...13 Mareli Systems WIRING DIAGRAM PB 40 52...

Страница 14: ...14 Mareli Systems NOTES...

Страница 15: ......

Страница 16: ...hey are due to printing or transcription errors We reserve the right to make any change that appears to be necessary or useful without harm the essential characteristics MareliSystems IndustrialZone S...

Отзывы: