1.

 

Specifications 

A/D Converter type 

Sigma-Delta 

Sample rate 

10 times / second, 40 times / second, 250 times / second 

Display resolution 

3000 

Internal resolution 

1,000,000 

Load cell excitation 

DC 5V 

Load cell 

Up to 4 x 350 Ω or 8 x 700 Ω load cell 

Display 

6-digit 0.4 inch LED 

Division 

1/2/5/0.1/0.2/0.5/0.01/0.02/0.05/0.001/0.002/0.005/10/ 
20/50/100/200/500/0.10/0.20/0.50/0.010/0.020/0.050 

Power 

DC 9V 1A adapter or AC 110-220V 50 Hz 

Operating temperature 

0

~40

 

Storage temperature 

-25

~55

 

Relative humidity 

85% RH 

Size 

95 × 48 × 110 mm 

Weight 

0.5 kg 

Signal output 

4-20 mA analog output 

Options 

a) Opto-isolated RS232 or RS485 
b) 6 relay outputs with 2 opto-isolated inputs that can be used 
to control the output of relay #1 and #2 

2.

 

Model Number 

  TD 2014□-□□-□ 

  - No interface 

1    - Optical -isolated RS232C 

2    - Optical -isolated RS485 

AC - AC 110-220V 50 Hz available for XK315A2-6A series only 

DC - DC 9V 1A adapter 

A    - Basic model with 4-20 mA analog output 

B    - Basic model plus 6 relay outputs and 2 opto-isolated 

inputs 

3.

 

Key Functions 

  * 

   

Function Select key or Enter key 

 

 

Right key 

T

 

Tare key or Increment key 

0

 

Zero key or Decrement key 

4.

 

Status 

T

 

On when tare and the weight is net weight 

0

 

On when the weight is zero 

〖◣◢〗

   

On when the weight is stable 

Содержание TD 2014 Series

Страница 1: ...User Manual TD 2014 Series Weighing Controller Applications Electronic platform scale weighing scale etc ...

Страница 2: ... Size 95 48 110 mm Weight 0 5 kg Signal output 4 20 mA analog output Options a Opto isolated RS232 or RS485 b 6 relay outputs with 2 opto isolated inputs that can be used to control the output of relay 1 and 2 2 Model Number TD 2014 0 No interface 1 Optical isolated RS232C 2 Optical isolated RS485 AC AC 110 220V 50 Hz available for XK315A2 6A series only DC DC 9V 1A adapter A Basic model with 4 20...

Страница 3: ...ntinuous ASCII regular data output if weight is 123 45 the output is 123 45 3 Adr 01 98 data output using ModBus protocol 8 Operation 1 Turn on the indicator it displays the version number and checks the LED from 0 to 9 2 Zero When the weight is stable between 2 FS press 0 zero the display and 0 is on When the zero reference is 2 FS it displays HHHHHH When the zero reference is 2 FS it displays LL...

Страница 4: ... to select filter Press AUtP00 Set zero trace range and zero at start range AUtP 00 no zero set at start zero trace range is 0 4d AUtP 10 zero at start range is 20 FS zero trace range is 0 4d AUtP 20 zero at start range is 20 FS zero trace range is 0 8d AUtP 30 zero at start range is 20 FS zero trace range is 1 2d AUtP 40 zero at start range is 20 FS zero trace range is 1 6d AUtP 50 zero at start ...

Страница 5: ...a combinations of T and 0 to change the magnification Press rAtE 1 Set AD sample rate 0 10 times second 1 40 times second 2 250 times second Press Or T rAtE 2 Press a combinations of T and 0 to change the sample rate Press 0 00 Save all parameters 10 Calibrations Operation Display Descriptions Press 000000 Go to Calibrations and Configurations menu and enter password 002003 Press Or T 002003 To en...

Страница 6: ... 000000 Go to Set Point menu and enter password 110906 Press Or T 110906 To enter password 110906 Press to move blinking digit to the right Press T to increment blinking digit Press 0 to decrement blinking digit Press A1 Set point 1 for relay 1 Press 000150 Press to access set point 1 Press Or T 000200 Press a combinations of T and 0 to set point A1 to 000200 Press A2 Set point 2 for relay 2 Follo...

Страница 7: ...g Press En o5 Set the output of 5 relay Follow step 14 to 16 to change relay output setting Press En o6 Set the output of 6 relay Follow step 14 to 16 to change relay output setting Press 0 00 Save set points 13 Software version VER2 01 packing scale VER2 02 3 speed rating scale VER2 03 check weighing VER2 04 2 materials 2 speed batching scale VER2 05 3 materials 2 speed batching scale VER2 06 4 m...

Страница 8: ...7 maintenance and calibration facilities 16 Relay output ...

Отзывы: