No. 7 Sets the mode the machine works in:
HEAT FILL (default
– minimises
temperature fluctuations),
CONT FILL (continuous fill
– makes sure
the tank is always full but temperature
may vary),
COOL FILL (allows cooling but reduces
tank size by using ECO mode),
MANUAL (manual filling).
See further explanations pg 8
HEAT
FILL
No. 8 Sets temperature units on screen.
Celsius
No.9 This sets max limit of the temperature that
user can set in USER SETUP; max value is
98.5 deg C
Celsius
No.10 Press the
eco
button to save all the
values and reset the machine.
-
DISPL AY INFORMATION DESCRIPTIONS:
Status
Description
BOILER OFF
Machine off. Display backlight off but temperature read-
out still working.
FILLING ...
Water level below low level probe. Machine is filling
automatically. Status LED
– 2 red blinks.
FILL THE TANK
Water level below low level probe. Machine has to be
refilled manually (shown only in MANUAL mode).
Status LED
– 2 red blinks.
WAIT ...
Water is being heated. Dispense valve disabled.
BOILER READY
Water is up to the temperature and can be used. Note that
this only means that the tank is heated and not that it is
full.
Status LED
– green.
DISPENSE
Water is being dispensed. If machine is set to time
dispenses
– there will also be a progress bar drawn
underneath. Dispense can always be cancelled by clicking
the dispense button again.
COOLING ...
Machine was set by the user to a lower temperature than
the current tank temperature and is trying to cool down by
taking in more cold water. This process may take between
20 seconds to a few minutes depending on tank size and
temperature difference. Works only in COOL FILL mode.