1900052
REV.6
Page 11
UC4L
Disconnect the machine from the electrical supply.
Allow to cool sufficiently.
On the 10L machine insert a flat headed screwdriver at the four locations indicated on the picture above
and rotate
. Note: -
There is no need to ‘lever’ the screwdriver – a small rotation is all that is required.
In the case of the 4L machine remove the 4 screws on the service panel located on the right hand side.
Place the panel to the side of the machine. This allows access to most of the internal components and
the machine does not need to be drained for most maintenance or service operations.
The Tank can be drained by removing the plug from the end of the drain hose, and draining into an
external drain or a large enough container.
FONT INSTALLATION:
The font is connected to the machine by a silicone hose and a control wire. The button on the
font triggers the pump in either
push and hold
or
push and release
mode. Please refer to
separate calibration instruction for setting of these modes. The calibration should only be
conducted by a trained service engineer.
The font’s silicone hose should be connected to the boiler hose adapter and secured with the
supplied hose clip.
The Boiler ideally should be positioned directly below the font installed position.
To help prevent heat loss between the tank and the dispense font, the silicone hose should be
insulated with the supplied hose insulation. Simply cut the insulation to the correct length
required.
Standard Font Connection
*Font will vary
.
Depending on font the type
the drip tray will either have
to be manually emptied
Or
Connected to a drain via
drip tray outlet.