background image

Blastmaster

®

 Smart Box

15

INSTALLATION

Apply pipe thread 

sealant to all pipe 

threads to ensure an 

airtight seal.

N-519

Always depressurize 

the entire system, 

disconnect all power 

sources and lockout/

tagout all components 

before any maintenance 

or troubleshooting is 

attempted. Failure to 

comply with the above 

warning could cause 

electrical shock and 

inadvertent activation of 

equipment resulting in 

death or serious injury.

W-562

Install Pressure Indicator - 6.5 cu. ft. and Smaller Abrasive Blasting Pots

Note: Additional components may be required to install Pressure Switch.

1)  Remove and retain Ball Valve (3) from Moisture Separator (9).

2)  Install Pipe Tee (1) on Moisture Separator (9).

3)  Install Pipe Nipple (2) and Bushing (4) on Pipe Tee (1).

4)  Install Hex Nipple (5) on Bushing (4).

5)  Install Pipe Tee (7) on pipe nipple (5).

6)  Install Pressure Transducer (6) on Pipe Tee (7).

7)  Install Pressure Sensor (8) on Pipe Tee (7).

8)  Install Ball Valve (3) on Pipe Nipple (2)

1

2

3

4

5

6

7

8

9

Содержание BLASTMASTER SMART BOX

Страница 1: ...employer of the user and or assistants must provide adequate and necessary training to ensure proper operation and compliance with all safety procedures pertaining to this equipment If Operator s Man...

Страница 2: ...ipment As the largest provider of surface preparation and protective coatings equipment in the world our inventory levels and product availability are unmatched Logistics Services Marco s in house log...

Страница 3: ...on which if not avoided could result in death or serious injury This is an example of a notice This indicates policy or practice directly related to safety of personnel or protection of property This...

Страница 4: ...y Standards Inspect all equipment for wear or damage before and after each use Failure to use Original Equipment Manufacturer repair parts and failure to immediately replace worn or damaged components...

Страница 5: ...n adequate concentrations To reduce conditions that could result in a fire or an explosion provide adequate ventilation eliminate all ignition or spark sources keep the work area free of debris store...

Страница 6: ...me of air exists and petcock is unable to be left open at all times petcock should be opened frequently to release water To reduce abrasive intrusion in the air supply hose depressurize the abrasive b...

Страница 7: ...r cfm Abrasive lbs hr Compressor Horsepower No 4 1 4 47 268 11 54 312 12 61 354 14 68 408 16 74 448 17 81 494 18 98 608 22 110 681 25 Air cfm Abrasive lbs hr Compressor Horsepower No 5 5 16 77 468 18...

Страница 8: ...Blastmaster Smart Box 7 THE BIG PICTURE 3 5 7 4 4 3 2 1 8 9 17 14 16 15 13 19 18 10 20 23 21 4 24 27 26 25 22 28 5 3 6 11 12...

Страница 9: ...ing Hose 19 and Air Hose 4 connection points Aftercooler and Moisture Separator Ensure Aftercooler 28 is positioned on stable ground Keep petcock drain of Moisture Separator 23 slightly open during us...

Страница 10: ...Timers 5 Pressurize abrasive blasting pot See abrasive blasting pot Operator s Manual During use When abrasive blasting pot is pressurized greater than 3 PSI Red indicator light 8 will activate alerti...

Страница 11: ...urces and lockout tagout all components before any maintenance or troubleshooting is attempted Failure to comply with the above warning could cause electrical shock and inadvertent activation of equip...

Страница 12: ...are active An hour glass is displayed in the top left corner to indicate they are counting Note The timers count in increments of 6 minutes 0 1 6 minutes 0 5 30 minutes 1 0 1 hour OPERATING INSTRUCTI...

Страница 13: ...g in death or serious injury W 562 Reset Production Timers Daily Production Timers 1 Open Cover 1 2 Select display to reset Push and hold correlating Reset Button 2 wait three seconds then release Thi...

Страница 14: ...ulting in death or serious injury W 562 Install Blastmaster Smart Box on Bulk Abrasive Blasting Pot Note Additional components may be required to install Blastmaster Smart Box 1 Install Enclosure 10 t...

Страница 15: ...ctivation of equipment resulting in death or serious injury W 562 Install Pressure Indicator Bulk Abrasive Blasting Pot Note Additional components may be required to install Pressure Switch 1 Disconne...

Страница 16: ...equipment resulting in death or serious injury W 562 Install Pressure Indicator 6 5 cu ft and Smaller Abrasive Blasting Pots Note Additional components may be required to install Pressure Switch 1 Re...

Страница 17: ...h the above warning could cause electrical shock and inadvertent activation of equipment resulting in death or serious injury W 562 Install Pressure Switch Blastmaster 125E 125P Remote Control System...

Страница 18: ...trical shock and inadvertent activation of equipment resulting in death or serious injury W 562 Install Pressure Switch Blastmaster 123E 123P Remote Control System Note Additional components may be re...

Страница 19: ...use electrical shock and inadvertent activation of equipment resulting in death or serious injury W 562 Install Pressure Switch Blastmaster 130P Remote Control System Note Additional components may be...

Страница 20: ...ld cause electrical shock and inadvertent activation of equipment resulting in death or serious injury W 562 Install Pressure Switch Blastmaster 130E Remote Control System Note Additional components m...

Страница 21: ...warning could cause electrical shock and inadvertent activation of equipment resulting in death or serious injury W 562 Install Pressure Switch Blastmaster 120E 120P Remote Control System Note Additi...

Страница 22: ...omply with the above warning could cause electrical shock and inadvertent activation of equipment resulting in death or serious injury W 562 Note Mark control line and remote control system to aid con...

Страница 23: ...ter 4 until reading matches analog gauge 6 Install Screws 2 and close Cover 1 MAINTENANCE Calibrate Digital Pressure Display Always depressurize the entire system disconnect all power sources and lock...

Страница 24: ...et Daily Production Timers in Operating Instructions Check if other reset buttons are functioning properly Contact Marco for further assistance Blastmaster Smart Box indica tor lights are not illumina...

Страница 25: ...Blastmaster Smart Box 24 MAINTENANCE NOTES DATE TYPE OF SERVICE PART NUMBER...

Страница 26: ...Blastmaster Smart Box 25 DATE TYPE OF SERVICE PART NUMBER MAINTENANCE NOTES...

Страница 27: ...THERS WITHOUT SELLER S PRIOR WRITTEN CONSENT IF SUCH NOTICE IS TIMELY GIVEN SELLER WILL HAVE THE OPTION TO EITHER MODIFY THE PRODUCT OR COMPONENT PART THEREOF TO CORRECT THE DEFECT REPLACE THE PRODUCT...

Страница 28: ...BLAST IT 800 252 7848 ph 563 324 2519 fax 563 324 6258 40 NATIONWIDE SHIPPING LOCATIONS Marco Regional Branch Offices and Shipping Locations Direct Shipping Locations CONTACT MARCO 800 BLAST IT 800 25...

Отзывы: