SP9 ServiceManual.docx 06/02/2015
Page 28 of 42
the heating element on the inside of the tank, remove the retaining nuts and seals on the outside.
The heating element can now be removed and replaced. See diagram on next page.
Note: Do not over-tighten the retaining nuts, as this could deform the seals and cause
leakage.
Over-Temperature Cut-Out Replacement
To replace the over-temperature cut-out switch, remove the spade connectors from the switch.
Remove the two retaining nuts and remove the switch. When replacing, use a little thermal
conductive paste to ensure good thermal conductivity. See diagram on next page.
Figure 18.
Содержание 1000830
Страница 7: ...SP9 ServiceManual docx 06 02 2015 Page 7 of 42 Figure 3 Figure 4...
Страница 11: ...SP9 ServiceManual docx 06 02 2015 Page 11 of 42 CONTROLS Figure 6 BREWING...
Страница 20: ...SP9 ServiceManual docx 06 02 2015 Page 20 of 42...
Страница 21: ...SP9 ServiceManual docx 06 02 2015 Page 21 of 42...
Страница 24: ...SP9 ServiceManual docx 06 02 2015 Page 24 of 42 Internal Component Map Figure 13...
Страница 31: ...SP9 ServiceManual docx 06 02 2015 Page 31 of 42 15 ELECTRICAL SCHEMATICS...
Страница 32: ...SP9 ServiceManual docx 06 02 2015 Page 32 of 42...
Страница 33: ...SP9 ServiceManual docx 06 02 2015 Page 33 of 42 16 SPARE PARTS SCHEMATICS...
Страница 35: ...SP9 ServiceManual docx 06 02 2015 Page 35 of 42...
Страница 36: ...SP9 ServiceManual docx 06 02 2015 Page 36 of 42...
Страница 37: ...SP9 ServiceManual docx 06 02 2015 Page 37 of 42 SP9 Head Unit Spare Parts...
Страница 39: ...SP9 ServiceManual docx 06 02 2015 Page 39 of 42 18 DIMENSIONED DRAWINGS...
Страница 40: ...SP9 ServiceManual docx 06 02 2015 Page 40 of 42...
Страница 41: ...SP9 ServiceManual docx 06 02 2015 Page 41 of 42 19 CUT OUT TEMPLATE...
Страница 42: ...SP9 ServiceManual docx 06 02 2015 Page 42 of 42 Installation Cut Out Template...