SP9 ServiceManual.docx 06/02/2015
Page 19 of 42
The most common error indication on a boiler is the Ready light giving two red flashes
between pauses, indicating that water can’t be seen in the tank. This can be caused by a
number of issues, most commonly, limescale or film build up on the water level probes.
Descaling Procedure:
Isolate machine from power supply.
Isolate machine from water supply.
ALLOW TO COOL COMPLETELY!
Drain water from machine.
Remove all lids.
Remove as much scale as possible by hand, paying particular attention to level probes
(White plastic with steel tab). Be very careful not to damage any attachments.
Use ScaleKleen, Marco part No. 8000270 or similar. Follow instructions carefully.
Thoroughly clean and flush the machine before re-use.
Clean water level probes with ScotchBrite
Follow installation and first time operation instructions
NB: Always clean the water level probes after descaling and rinsing the tank.
To Clean Water Level Probes:
Turn off water feed to unit
Dispense as much water from unit as possible using two clicks at the head unit
Turn off unit at wall socket or unplug from wall socket
Remove top cover from boiler
Remove tank lid from tank
Identify water level probes
– flat metal tabs inside water tank - 3 probes
Thoroughly clean probes with ScotchBrite (or scouring pad)
Replace tank lid and top cover
Reconnect power and water to boiler and operate as normal
Содержание 1000830
Страница 7: ...SP9 ServiceManual docx 06 02 2015 Page 7 of 42 Figure 3 Figure 4...
Страница 11: ...SP9 ServiceManual docx 06 02 2015 Page 11 of 42 CONTROLS Figure 6 BREWING...
Страница 20: ...SP9 ServiceManual docx 06 02 2015 Page 20 of 42...
Страница 21: ...SP9 ServiceManual docx 06 02 2015 Page 21 of 42...
Страница 24: ...SP9 ServiceManual docx 06 02 2015 Page 24 of 42 Internal Component Map Figure 13...
Страница 31: ...SP9 ServiceManual docx 06 02 2015 Page 31 of 42 15 ELECTRICAL SCHEMATICS...
Страница 32: ...SP9 ServiceManual docx 06 02 2015 Page 32 of 42...
Страница 33: ...SP9 ServiceManual docx 06 02 2015 Page 33 of 42 16 SPARE PARTS SCHEMATICS...
Страница 35: ...SP9 ServiceManual docx 06 02 2015 Page 35 of 42...
Страница 36: ...SP9 ServiceManual docx 06 02 2015 Page 36 of 42...
Страница 37: ...SP9 ServiceManual docx 06 02 2015 Page 37 of 42 SP9 Head Unit Spare Parts...
Страница 39: ...SP9 ServiceManual docx 06 02 2015 Page 39 of 42 18 DIMENSIONED DRAWINGS...
Страница 40: ...SP9 ServiceManual docx 06 02 2015 Page 40 of 42...
Страница 41: ...SP9 ServiceManual docx 06 02 2015 Page 41 of 42 19 CUT OUT TEMPLATE...
Страница 42: ...SP9 ServiceManual docx 06 02 2015 Page 42 of 42 Installation Cut Out Template...