Service manual April 2017 Ecoboiler UC45
Page 9 of 28
6 FLASH CYCLE
– NOT FILLING
Display pattern:
•
6 flashes then a short pause - repeated.
Electronic check
and action:
•
This checks that the water in the tank cools when the inlet solenoid
valve is switched on.
•
This is a recoverable error. This checks that the water in the tank is
cooled by when the inlet solenoid valve is opened. If the water pressure
is within the specifications (5-50psi), the inlet solenoid should not be on
for more than a few seconds.
Probable causes:
•
Mains water pressure problem or the mains water stop valve is closed.
•
Inlet solenoid valve failure.
Action required:
•
Check the mains water supply. (Note: Temporary loss of water pressure
can occur in certain sites
– particularly when various machines are
plumbed to the same mains water supply.) If the water supply is
restored machine will recover automatically.
•
NOTE: If the water supply is the problem, ensure that this is
rectified or this error will re-occur.
•
If there is no problem with the mains water supply, check that the inlet
solenoid valve is working.
3.6.
M AINT ENANCE:
Marco machines have been designed to give many years of trouble free service. Marco Beverage
Systems manufacture and test to ISO9002:2000 standard. The only regular maintenance required is
occasional de-scaling.
Descaling Procedure:
•
Isolate machine from power supply.
•
Isolate machine from water supply.
•
ALLOW TO COOL COMPLETELY!
•
Drain water from machine.
•
Remove all lids.
•
Remove as much scale as possible by hand, paying particular attention to level probes (White
plastic with steel tab). Be very careful not to damage any attachments.
•
Use ScaleKleen, Marco part No. 8000270 or similar. Follow instructions carefully.
•
Thoroughly clean and flush the machine before re-use.
•
Follow installation and first time operation instructions
3.7.
CLE ANING:
The exterior of these machines may be cleaned with a damp cloth and a light detergent. Do not use
abrasive cloths or creams, as this will spoil the finish of the machine. Do not use a water jet or spray.
Beware of accidentally operating the draw off tap or push button when cleaning the front of the
machine.
3.8.
LIM ESCALE:
In common with all water boiler manufacturers, service calls resulting from limescale are not covered
by warranty. Fitting a scale reducer is recommended, especially in hard water areas. This can
reduce the build-up of scale but may not stop it altogether. The frequency that descaling is required
depends on the local water supply; hard water areas need more attention. A scale reducer can
reduce the build up of scaling, but may not stop it altogether. Descaling of the machine should ideally
be carried out by qualified service personnel.
Содержание Ecoboiler UC45 1000743
Страница 14: ...Service manual April 2017 Ecoboiler UC45 Page 14 of 28...
Страница 15: ...Service manual April 2017 Ecoboiler UC45 Page 15 of 28 4 4 INTERNAL ARRANGEMENT...
Страница 21: ...Service manual April 2017 Ecoboiler UC45 Page 21 of 28 4 9 Wiring diagram 1000743 1000743A...
Страница 22: ...Service manual April 2017 Ecoboiler UC45 Page 22 of 28 4 10 Wiring Diagrams 1000744 1000744A 1000744US...
Страница 23: ...Service manual April 2017 Ecoboiler UC45 Page 23 of 28 4 11 Wiring Diagram 1000745 1000745A...
Страница 24: ...Service manual April 2017 Ecoboiler UC45 Page 24 of 28 4 12 Wiring Diagram 1000753 1000753A...
Страница 25: ...Service manual April 2017 Ecoboiler UC45 Page 25 of 28 4 12 Wiring Diagram 1000754 1000754A...
Страница 26: ...Service manual April 2017 Ecoboiler UC45 Page 26 of 28 4 12 Wiring Diagram 1000755 1000755A...
Страница 27: ...Service manual April 2017 Ecoboiler UC45 Page 27 of 28 4 13 Spare Parts List...