Service manual April 2017 Ecoboiler UC45
Page 8 of 28
3 FLASH CYCLE
– THERMISTOR OPEN CIRCUIT
Display pattern:
•
3 flashes then a short pause - repeated.
Electronic check
and action:
•
This indicates that the Thermistor is measuring such a large resistance
that it assumes the thermistor circuit is open.
•
The element and inlet valve are turned OFF when this error is detected
•
This is a recoverable error. When the correct range of resistance is
measured, normal operation resumes
Probable causes:
•
The thermistor probe is unplugged from the 4way connector on the PCB
or the thermistor has failed open circuit.
Action required:
•
Check that the thermistor is plugged in to the PCB correctly. If it is,
replace the thermistor.
4 FLASH CYCLE
– NOT HEATING
Display pattern:
•
4 flashes then a short pause - repeated.
Electronic check
and action:
•
This checks that the temperature is increasing when the heater is on.
•
Measures the rate that the temperature increases in a specified time.
This error is only displayed after 20 mins of the heater being on
continuously. When the error is detected, the element and inlet valve are
turned off.
•
This is a non-recoverable error. The machine needs to be reset when
this problem is solved.
Probable causes:
•
The elements have failed
•
Wiring fault
Action required:
•
Check that the resistance on the elements. If there is a reasonable
resistance (15-
25Ω)on the element it probably has not failed, so the
wiring might be at fault.
5 FLASH CYCLE
– THERMISTOR SHORT CIRCUIT
Display pattern:
•
5 flashes then a short pause - repeated.
Electronic check
and action:
•
This indicates that the Thermistor is measuring zero resistance. It
assumes the thermistor has failed short circuit.
•
The element and inlet valve are turned OFF when this error is detected
•
This is a recoverable error. When the correct range of resistance is
measured, normal operation resumes.
Probable causes:
•
The thermistor has failed.
Action required:
•
Replace the thermistor.
Содержание Ecoboiler UC45 1000743
Страница 14: ...Service manual April 2017 Ecoboiler UC45 Page 14 of 28...
Страница 15: ...Service manual April 2017 Ecoboiler UC45 Page 15 of 28 4 4 INTERNAL ARRANGEMENT...
Страница 21: ...Service manual April 2017 Ecoboiler UC45 Page 21 of 28 4 9 Wiring diagram 1000743 1000743A...
Страница 22: ...Service manual April 2017 Ecoboiler UC45 Page 22 of 28 4 10 Wiring Diagrams 1000744 1000744A 1000744US...
Страница 23: ...Service manual April 2017 Ecoboiler UC45 Page 23 of 28 4 11 Wiring Diagram 1000745 1000745A...
Страница 24: ...Service manual April 2017 Ecoboiler UC45 Page 24 of 28 4 12 Wiring Diagram 1000753 1000753A...
Страница 25: ...Service manual April 2017 Ecoboiler UC45 Page 25 of 28 4 12 Wiring Diagram 1000754 1000754A...
Страница 26: ...Service manual April 2017 Ecoboiler UC45 Page 26 of 28 4 12 Wiring Diagram 1000755 1000755A...
Страница 27: ...Service manual April 2017 Ecoboiler UC45 Page 27 of 28 4 13 Spare Parts List...