Service manual April 2017 Ecoboiler UC45
Page 6 of 28
•
Do the same action with the other font if needed. If only one font is calibrated, settings for
the other will not be altered.
•
The minimum time possible for the time dispense operation is 1s. Setting the dispense time
for less (quick font button click) will set the font back into "push & hold" mode.
•
After the volumes are set properly press the tactile button on the timer board once again.
•
Both pumps will turn on and off for 0.1s twice - that will be heard as a double click meaning
that the timer is out of calibration.
•
Please note that there is no given order which font is to be calibrated first - in fact they may
be calibrated at once or only one may be calibrated (leaving the settings of the other
unaltered).
•
If there is no response from the user in the calibration mode (none of the font buttons
pressed) for more than 25 seconds the timer will end the calibration (double pump "click"
will be heard).
•
The maximum allowable time of dispense is 25 seconds. Any longer times will be cut down
to 25 seconds.
•
The resolution of the time measurement is 0.1s.
•
The timer board has its own clock on board therefore power line frequency is not used to
measure the time.
3.4.2. Setting time dispense for right hand side pump (3 font version only)
3.4.2.1. Eco Boiler version
•
Open the service panel.
•
Make sure that the machine is powered, filled and heated (ready lamp green).
•
Press calibration tactile button on the bottom control PCB for a second until status lamp
starts blinking red-green.
•
Set new dispense time by pressing dispense button to obtain the required output volume of
water. Button may be pressed several times
– all times / volumes will be added together.
•
To confirm and save new value press calibration button on the PCB for a second until the
status lamp stops blinking.
•
Setting dispense time / volume to zero (omit step 4) will make the machine work as “push &
hold” (water dispensed as long as the button is pressed).
3.4.2.2. Eco Smart version
•
Press and release Power and ECO buttons simultaneously.
•
User setup screen will appear on the display.
•
Click Power button to highlight TIME DISP option.
•
Use ECO button to increase value (button can be held for repeated increase). Once the
value goes above the max value 99.9s it will reset to 0 and start incrementing from that
value.
•
Setting dispense time to 0 will make the pump work in push-and-hold mode.
•
Once you set new dispense time use Power button to scroll through other options until you
find SAVE AND EXIT and press ECO button to accept.
•
Machine will reset and go back into main screen.
Содержание Ecoboiler UC45 1000743
Страница 14: ...Service manual April 2017 Ecoboiler UC45 Page 14 of 28...
Страница 15: ...Service manual April 2017 Ecoboiler UC45 Page 15 of 28 4 4 INTERNAL ARRANGEMENT...
Страница 21: ...Service manual April 2017 Ecoboiler UC45 Page 21 of 28 4 9 Wiring diagram 1000743 1000743A...
Страница 22: ...Service manual April 2017 Ecoboiler UC45 Page 22 of 28 4 10 Wiring Diagrams 1000744 1000744A 1000744US...
Страница 23: ...Service manual April 2017 Ecoboiler UC45 Page 23 of 28 4 11 Wiring Diagram 1000745 1000745A...
Страница 24: ...Service manual April 2017 Ecoboiler UC45 Page 24 of 28 4 12 Wiring Diagram 1000753 1000753A...
Страница 25: ...Service manual April 2017 Ecoboiler UC45 Page 25 of 28 4 12 Wiring Diagram 1000754 1000754A...
Страница 26: ...Service manual April 2017 Ecoboiler UC45 Page 26 of 28 4 12 Wiring Diagram 1000755 1000755A...
Страница 27: ...Service manual April 2017 Ecoboiler UC45 Page 27 of 28 4 13 Spare Parts List...