![Marco Beverage Systems Ecoboiler UC45 1000743 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/marco-beverage-systems/ecoboiler-uc45-1000743/ecoboiler-uc45-1000743_service-manual_1726606010.webp)
Service manual April 2017 Ecoboiler UC45
Page 10 of 28
3.9.
CAUT IONS AND S AFET Y T IPS:
•
This appliance must be earthed. If the moulded plug supplied is not used then ensure that the
green/yellow cable is connected to a suitable earth.
•
Risk of flooding. The hose supplied with this unit is non-toxic food quality tested to 190psi.
However, a hose is not a permanent connection. It is, therefore, advisable to switch off boiler
and close the stopcock valve when boiler is not in use, e.g. overnight, weekends etc.
•
Risk of scalding. Beware of accidentally operating the water drawoff tap especially when
cleaning the front of the boiler.
•
The utmost care has been taken in the manufacture and testing of this unit. Failure to install,
maintain and / or operate this boiler according to the manufacturer’s instructions may result in
conditions that can cause injury or damage to property. If in any doubt about the serviceability
of the boiler always contact the manufacturer or your own supplier for advice.
4. Technical Data:
4.1. GENERAL DESCRIPT ION:
1000743/
A (2.8kW)
1000744/A
(5.6kW)
1000745/A
(8.4kW)
1000753/A
(2.8kW)
1000754/A
(5.6kW)
1000755/A
(8.4kW)
1000744US
(5.6kW)
D
im
e
n
si
o
n
s
Height (mm)
Width (mm)
Depth (mm)
650
420
495
650
420
495
650
420
495
650
420
495
650
420
495
650
420
495
650
420
495
P
e
rfo
rm
a
n
ce
I
mmediate Draw-
Off (litres)
Min. Hourly
Output (L/hr)
45L
27L
45L
54L
45L
81L
45L
27L
45L
54L
45L
81L
45L
54L
E
le
ct
ric
a
l
Connection
2.8kW,
230V, c/w
1.5m flex
and
moulded
plug -
fused
(BS1363).
5.6kW. must
be
connected to
single phase
power
supply
8.4kW. must
be
connected to
three phase
power
supply
2.8kW 230V,
c/w 1.5m flex
and moulded
plug - fused
(BS1363).
5.6kW. must
be
connected to
single phase
power
supply
8.4kW. must
be
connected to
three phase
power
supply
5.6kW. must
be
connected to
single phase
power
supply
P
lu
m
b
in
g
Fittings
Pressure
0.75” BSP
Food grade inlet hose supplied
5-50 psi (35-345 kPa)
Содержание Ecoboiler UC45 1000743
Страница 14: ...Service manual April 2017 Ecoboiler UC45 Page 14 of 28...
Страница 15: ...Service manual April 2017 Ecoboiler UC45 Page 15 of 28 4 4 INTERNAL ARRANGEMENT...
Страница 21: ...Service manual April 2017 Ecoboiler UC45 Page 21 of 28 4 9 Wiring diagram 1000743 1000743A...
Страница 22: ...Service manual April 2017 Ecoboiler UC45 Page 22 of 28 4 10 Wiring Diagrams 1000744 1000744A 1000744US...
Страница 23: ...Service manual April 2017 Ecoboiler UC45 Page 23 of 28 4 11 Wiring Diagram 1000745 1000745A...
Страница 24: ...Service manual April 2017 Ecoboiler UC45 Page 24 of 28 4 12 Wiring Diagram 1000753 1000753A...
Страница 25: ...Service manual April 2017 Ecoboiler UC45 Page 25 of 28 4 12 Wiring Diagram 1000754 1000754A...
Страница 26: ...Service manual April 2017 Ecoboiler UC45 Page 26 of 28 4 12 Wiring Diagram 1000755 1000755A...
Страница 27: ...Service manual April 2017 Ecoboiler UC45 Page 27 of 28 4 13 Spare Parts List...