background image

Security

 

Sub

-

menu

 

 

this

 

sub

-

menu

 

allows

 

the

 

User

 

to

 

set

 

the

 

parameters

 

shown

lock

 

the

 

DPA240P

 

and

 

set

 

a

 

Password

 

therefore

 

limiting

 

the

 

unit

'

s

 

functions

 

and

 

controls

 

to

 

those

 

who

have

 

access

 

to

 

the

 

appropriate

 

Password

.

Press

 

ENTER

 

and

 

then

 

use

 

the

 

NAV

/

PM1

 

to

 

scroll

 

between

 

options

Show

 

Parameter

:

 

Pressing

 

ENTER

 

from

 

the

 

above

 

menu

 

will

 

access

 

the

 “

Show

 

Parameter

Sub

 

Menu

Press

 

ENTER

 

again

 

and

 

use

 

the

 

PM2

 

or

 

PM3

 

encoders

 

to

 

scroll

 

between

 

the

be

 

shown

and

not

 

be

 

shown

” 

options

.  

An

 

asterisk

 

will

 

highlight

 

which

 

option

 

is

 

selected

.

Choosing

 

the

  “

be

 

shown

”  

option

 

means

 

that

 

once

 

the

 

unit

 

is

 

locked

,

you

 

cannot

 

access

parameter

 

editing

 

features

but

 

they

 

will

 

be

 

displayed

 

on

 

the

 

LCD

 

screen

.

Choosing

 

the

 “

not

 

be

 

shown

” 

option

 

means

 

that

 

once

 

the

 

unit

 

is

 

locked

the

 

parameters

 

will

not

 

be

 

shown

 

at

 

all

.   

With

 

this

 

option

when

 

trying

 

to

 

access

 

a

 

parameter

the

 

following

 

screen

message

 

will

 

appear

:

Lock

 

Unit

:

  

this

 

sub

-

menu

 

allows

 

the

 

user

 

to

 

lock

 

the

 

device

 

so

 

no

 

parameters

 

can

 

be

 

edited

or

 

modified

.

When

 

the

 

Unit

 

is

 

in

 

an

 

unlocked

 

condition

all

 

parameters

 

will

 

be

 

available

 

for

 

editing

.  

When

you

 

select

 

On

all

 

parameters

 

will

 

be

 

locked

 

and

 

are

 

not

 

available

 

for

 

editing

.

When

 

you

 

select

 

lock

 

from

 

the

 

menu

the

 

unit

 

will

 

be

 

locked

 

and

 

the

 

lock

 

menu

 

automatically

exited

.  

The

 

screen

 

will

 

revert

 

to

 

the

 “

Default

showing

 

the

 

current

 

XOVER

 

configuration

 

and

the

 

preset

 

selected

 

and

 

beside

 

the

 

preset

s

 

name

 

a

keylock

icon

 

indicating

 

that

 

the

DPA240P

 

is

 

locked

.

UTILITY

 

MENU

–     

Security

 

Utilities

      --

SECURITY

 

UTILITY

–    

Show

 

Parameter

      –

Parameter

 

will

not

 

be

 

shown

     *

SECURITY

 

UTILITY

--        

Lock

 

Unit

         --

Lock

 

Unit

   

Lock

 :  

On

            *

2 In - 4 Out Speaker Management System

Содержание DPA240P

Страница 1: ...2 In 4 Out Speaker Management System DPA240P 2 In 4 Out Speaker Management System...

Страница 2: ...ffers up to 5 band of parametric equalization in to the crossover filters which themselves provide slopes from 6dB Octave up to 48dB Octave Each output path also features peak limiter and driver align...

Страница 3: ...0P initialization process The DPA240P has three factory pre set working modes After the initialization the DPA240P will show on the LCD the first of the embedded preset working modes or the last one s...

Страница 4: ...or B are either muted or unmuted The red LED will illuminate when the Channel is muted When the MUTE LED is OFF then the related Input Channel is UN MUTED A momentary push of the A and B buttons enter...

Страница 5: ...01 2 3 PROGRAM UTILITY Delete a Program Delete a Program 01 Preset 01 3 UTILITY MENU Interface Utilities 3 1 INTERFACE UTILITY Interface Setup Interface Setup Source USB Source RS485 4 UTILITY MENU S...

Страница 6: ...ff ENTER ESC 6 1a If selected a Peaking_Eq filter then the filter can be set by the following parameters Input A BEQ x up to 5 filters available Freq Gain Q 1000Hz 0 0dB Q 1 00 6 1b If selected a Hi S...

Страница 7: ...Hz Through the PM2 it is possible to Bypass the filter or to select one of the 11 available filters type orders and through the PM3 to set the HP cutting Frequency quick fine tuning by 1Hz steps Once...

Страница 8: ...mp Act 6 Out x Name Name Name Name Name _ For Editing the Device s Name refer to the Details on the Utility Menus Use Section 7 Out x Name Source Source InA Source InA PM1 N A InA Channel A Same as PM...

Страница 9: ...d option will mean an asterisk will then appear and this option will now take over as the currently selected running option System Utilities Sub menu this sub menu allows to access several operations...

Страница 10: ...r The new preset mode will now be shown with an asterisk New Xover ENTER to confirm Please Wait Changing Xover System Setup Setup 1x2 WAY XOVER 2 In 4 Out Speaker Management System Delay Time Distance...

Страница 11: ...presets have previously been stored by the user anyone of them can be recalled By using the PM2 or PM3 encoder it is possible to scroll through the stored presets Once the desired preset appears on th...

Страница 12: ...er can enter a Preset Name up to 16 Characters by using the PM2 or PM3 encoder to choose a character and the NAV PM1 encoder to move between the 16 available locations for the character s positioning...

Страница 13: ...ge allows you to delete a preset already stored in the DPA240P memory By pressing the ENTER button and rotating the PM2 or PM3 encoder it is possible to scroll through the previously saved presets and...

Страница 14: ...d for controlling the DPA240P From Interface Utilities press ENTER to access the Interface Setup Interface Setup this screen allows you to choose the remote control protocol for the DPA240P By pressin...

Страница 15: ...own option means that once the unit is locked the parameters will not be shown at all With this option when trying to access a parameter the following screen message will appear Lock Unit this sub men...

Страница 16: ...will exit the Unit Lock sub menu and jump to the User Password sub menu page screen If the password entered in the Confirm Password page matches the one entered in the Enter Password page the followin...

Страница 17: ...w Parameter Sub Menu has been selected Once Locked by Password the keylock icon will appear on the default LCD screen and no menu pages will be accessible with the exception of the User Password optio...

Страница 18: ...40P system status once leaving the page Note2 to exit this page push the ESC button Gain page from this screen it is possible to set the Input Channels Level from 15dB to 15dB press ENTER an arrow wil...

Страница 19: ...single filter of the 4 available in the Equalizer section Once in the editing page of the single filter a Byp field is available for making the single filter active or not Pushing the Enter Button the...

Страница 20: ...z the PM2 by steps of one hundred Hz and the PM3 by steps of one Hz Hi_Shelv_Q Filter These Symmetrical Shelving filters present level of the selected Gain Attenuation at the selected cutting frequenc...

Страница 21: ...r Input Channel 1 To Edit press ENTER on the Name Page and the entering arrow will appear as in the example below The first letter position will be blinking Select the Character position from the 6 av...

Страница 22: ...nnels High Pass Filter Once on the HPF page Pressing the ENTER Button the filter type fields and the Cutting frequency fields become accessible for the filter s type selection and the Cutting Frequenc...

Страница 23: ...om Filter where this means that the HPF is builded as cascade of IInd Order Cells which number is depending from the filter s order and where for each Cell can be set independently the Low Cut frequen...

Страница 24: ...LPF sub menu from this sub menu it is possible to set the Output Channels Low Pass Filter Once on the LPF page Pressing the ENTER Button the filter type fields and the Cutting frequency fields become...

Страница 25: ...er s order and where for each Cell can be set independently the High Cut frequency and the Q More precisely the available independent parameters for setting are the following 1 Customm_2nd builded usi...

Страница 26: ...ed on the Output Signal Path When Bypassed the 5 Bands Equalizer its current setting will not be lost EQ x sub menu from this sub menu it is possible to set the Output Channels five available Multi Ty...

Страница 27: ...using the NAV PM1 PM2 and PM3 encoders for editing the Filter s Center Frequency Gain and Q Center Frequency the selectable frequencies range is from 20Hz to 20kHz in steps of 1Hz and can be adjusted...

Страница 28: ...at 3 5 using the PM3 encoder the EQ sub menu screen will show the following Once in the All Pass_2 Filter s edit screen all the filter s parameters can be modified using the NAV PM1 and PM3 encoders f...

Страница 29: ...le to assign one of the following Inputs to any Output Channel 1 Input A 2 Input B 3 Sum of Input A 2 Input B 2 The following is an example screen for the Source where Input A is assigned to Output Ch...

Страница 30: ...s possible to set the Output Channels Delay Time from 000 0000mS up to 399 0000mS by steps of 1mS or 20 8uS To set the Delay time press ENTER an arrow will appear on the left of the screen then use th...

Страница 31: ...hannels will be selected ready for adjustment when their Blue LED is lit in the Editing mode Now all Slave channels and only those selected will modify their parameters accordingly as you edit the Mas...

Страница 32: ...arameters will be permanently lost Use the following procedure to perform the factory reset 1 While the DPA240P is switched OFF simultaneously press the ENTER ESC UTILITY buttons on the front panel 2...

Страница 33: ...the Preset is initialized available or not yet created B If YES then the microcontroller will send back to the User eg Crestron AMX Remote Control the same frame used by the command RX STX ID_M ID_N...

Страница 34: ...7 Out1 Out6 when Channel 0 1 selected then Vol Input Gain when Channel 2 3 4 5 6 7 selected then Vol Output Vol Phs Phase only if the Chn 1 Value 0 1 where 0 direct 1 inverse 180 Vol Gains from 0 to...

Страница 35: ...Female XLR Maximum Input Level 16dBu Analog Output Signal Ch1 Ch2 Ch3 Ch4 Bal Male XLR Maximum Output Level 16dBu Digital Processing DSP SAM3716 24bits data x 96 bits coeff A D D A Converters CS42528...

Страница 36: ...2 In 4 Out Speaker Management System...

Отзывы: