DEGASSING SYSTEM DG-50
INSTALLATION OPERATION & MAINTENANCE MANUAL
MA-DG-50r01
10
4.2
Process connections
Depending on the degassing system option chosen, process connections may vary in number and type,
according to the next chart:
CONNECTION
DESCRIPTION
DG50-0-C
DG50-0-D
DG50-1-C
DG50-1-D
SAMPLE INLET
1/4“ NPTF
1/4“ NPTF
1/4“ NPTF
1/4“ NPTF
SAMPLE OUTLET
1/4“ NPTF
1/4“ NPTF
1/4“ NPTF
1/4“ NPTF
DRAIN
1/2“ NPTM
1/2“ NPTM
1/2“ NPTM
1/2“ NPTM
COOLING WATER INLET
N/A
N/A
1/4“ NPTF
1/4“ NPTF
COOLING WATER OUTLET
N/A
N/A
1/4“ NPTF
1/4“ NPTF
Cooling water connections
Cooling water connections are not required when self-cooling option is installed. In case of external cooling
water option, follow next steps:
•
Keep the length of all tubing to a minimum. Only 80 mm of straight tube, must be respected
from connection fitting (¼” NPTF) to the previous curve upstream.
•
Connect the cooling water IN. Should be piped to the left lower side of the mounting plate, in
¼” nominal bore tube and connected by means of ¼” NPTM fitting to ¼ NPTF connector.
Connection is labelled with the indication “COOLING W. IN”.
•
Pipe the cooling water OUT. Should be piped to the left lower side of the mounting plate, in ¼”
nominal bore tube and connected by means of ¼” NPTM fitting to ¼ NPTF connector.
Connection is labelled with the indication “COOLING W. OUT”.
Cooling water inlet and outlet connections