3

ORDER CODES FOR PIPE ADAPTOR FITTINGS 

RPFS

 

 

 

Material 

GAL 

PVC 

PVC 

Polypropylene 

Polypropylene STAINLESS

BRASS

BRASS 

Type 

T-Piece 

slip T-piece  Saddle Clamp

Saddle Clamp 

Saddle 

Clamp 

T-Piece 

T-piece

Socket 

For 

Gal pipe 

Pressure pipe 

Pressure pipe 

Pressure pipe 

Poly Pipe 

Black 

S/Steel pipe

Brass 
pipe 

 

20   mm 

 

PVC20 

 

 

 

 

BRA20 

 

25   mm 

GAL25 ( -T2) 

PVC25 

 

 

 

SS25 

BRA25 

 

32   mm 

GAL32 

PVC32 

 

 

 

SS32 

 

BSOC: 
1” BSP  

Brass  

pipe socket  

adaptor  

for  

25-100

mm

  

pipes 

also 

BSPB & 

BSPSS 

nipple adaptor 

40   mm 

GAL40 

PVC40 

PVC40SC 

SCP40 

SC40 

SS40 

 

50   mm 

GAL50 

PVC50 

PVC50SC 

SCP50 

SC50 

SS50 

 

63   mm 

 

 

 

SCPE63 

SC63 

 

 

65   mm 

 

PVC65 

 

SCP65 

SC75 

 

 

75   mm 

 

 

 

 

SC75 

 

 

80   mm 

GAL80 

PVC80 

PVC80SC 

SCP80 

SC90 

 

 

80   mm   GAL80-F 

(Table D flanged)

 

 

 

 

 

 

 

90   mm 

 

 

 

SCPE90 

SC90 

 

 

100 mm 

GAL100 

PVC100 

PVC100SC 

SCP100 

SC114 

 

 

100 mm 

GAL100-F 

(Table D flanged)

 

 

 

 

 

 

 

 

110 mm 

 

 

 

SCPE110 

SC110 

 

 

 

BSOC: 
1” BSP  

Brass  

pipe socket  

adaptor  

for  

100-500  

mm pipes 

also 

BSPB-LS 

Long Stem 

nipple adaptor

 

125 mm 

 

 

 

SCPE125-LS 

SC125-LS 

 

 

140 mm 

 

 

 

 

SC140-LS 

 

 

150 mm 

 

 

PVC150SC-LS

SCP150-LS 

SC160-LS 

 

 

160 mm 

 

 

 

SCPE160-LS 

SC160-LS 

 

 

200 mm 

 

 

PVC200SC-LS

SCP200-LS 

SC200-LS 

 

 

225 mm 

 

 

 

SCPE225-LS 

SC225-LS 

 

 

250 mm 

 

 

 

SCP250-LS 

SC250-LS 

 

 

280 mm 

 

 

 

 

SC280-LS 

 

 

300 mm 

 

 

PVC300SC-LS

SCPE300-LS 

SC315-LS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 

 

 

Galvanised iron   
threaded ends  
BSP (female) 
2000 kPa 
Note: 25mm   
can be supplied  
with straight  
pipe sections  
already fitted  
(Part GAL25-T2) 

PVC 

T-piece 

Class 18 Cat 

19 

Glue-in 

(female) 

1100 kPa 

PVC 

 

1400 kPa 

PVC 

 

 

 

≤ 150mm:  

1600 kPa  

 

> 150mm:  

1000 kPa 

Poly-pipe 

agricultural 

Saddle Clamps 

 

≤ 150mm:  

1600 kPa  

 

> 150mm:  

1000 kPa 

Stainless 

Steel 316  

T-piece.  

 

BSP 

(female) 

threaded entry

 

2000 kPa 

 

Brass  

T-piece  

 
 

BSP 

(female) 

threaded 

entry 

 

2000 kPa

 

1” BSP  

Brass  

pipe  

socket 

adaptor  

& BSPB 

BSPB-LS  

BSPSS 

nipple 

adaptors 

(see Fig 1 

Page 3)

 

 

 

GAL80 - 80mm Galvanized Iron pipe adapter  

 

 

(80mm ɸ  x  600mm long) 

BSPSS Stainless Steel 

adapter nipple 

for 25-100mm pipes 

BSPB brass 

adapter nipple 

for 25-100mm 

pipes 

 

 

 

Due to continuous product improvement, specifications are subject to change without notice

.

 

 
 
 
 

** Pipe fitting options for the RPFS are as per the table however other fitting types may also be available on request** 

Содержание ManuFlo ME3000-RPFS

Страница 1: ...flowmeter as per the installation guide found on the flowmeter brochure Install the Rota Pulse paddlewheel sensor RPFS P in a straight pipe section with the same diameter pipe as the adaptor tee section with 10x diameter before and 5x diameter after the sensor with no elbows reducers valves or restrictions within this pipe run Where the sensor is housed the pipe must be full when measuring D Use s...

Страница 2: ...nd continuously if an error occurs With the ME3000 Batch Controller using the same instrument housing and the same 10 pin Weidmuller receptacle plug as other ManuFlo Batch Controller models changeover or upgrade is instant with no rewiring necessary It can be easily interfaced with PLCs through the optional computer control interface thus incorporating the controller s safety features and providin...

Страница 3: ...nfiguration value is diplayed entering a new value via the keypad causes the display value to change and flash Then pressing SET locks in the new value or pressing CANCEL reverts value to its original setting and the display digits stop flashing Use the up down arrows buttons to step through more configuration settings or press CANCEL for 2 seconds to exit to the SET RDY display CALIBRATION 1 The ...

Страница 4: ...nel Eagle etc PLCs MC 4 pin PLC Computer Command Start Stop Reset interface plug MC2 2 pin plug for scaled open collector pulse output Includes 4 pin external command Start Stop Reset interface plug e g ME3000 is the standard Batch Controller 240vac powered without any of the options whereas ME3000 MC2 is an ME3000 Batch Controller with a scaled open collector pulse o p and external Start Stop Res...

Страница 5: ...tion to larger size pipes is possible depending on pipe wall thickness alternatively the Long Stem LS versions with adaptors are then used With only one moving part and limited intrusion into the pipe and combined with its flow through design the RPFS allows accurate measurement of liquid flows with virtually no head losses Each of the 4 blades of the rotor paddlewheel extends approximately one ce...

Страница 6: ...G 6 1 Unscrew the black PVC locking cap anti clockwise 2 Hold the neck of the Tee piece in your left hand grasp the RPFS body with your right hand and turn slowly anti clockwise until the sensor hydraulically raises out of slot then pull upwards out of the socket never by the cable When returning the sensor to nipple adaptor insert so the keyway and slots line up then then push down until they loc...

Страница 7: ...e If mounted in horizontal or inclined pipe make sure insertion position of sensor is at top or 45 from top not on the underside Selection of pipe diameter For best results use the table below Pipe size Flowrange Litres min Pulses Litre mm Min Max approx 1 2 20 13 160 116 25 20 250 75 32 30 410 46 40 50 640 30 50 90 1000 20 63 132 1580 11 7 65 120 1690 12 75 180 2250 8 3 80 190 2560 7 3 90 244 324...

Страница 8: ...25 LS 140 mm SC140 LS 150 mm PVC150SC LS SCP150 LS SC160 LS 160 mm SCPE160 LS SC160 LS 200 mm PVC200SC LS SCP200 LS SC200 LS 225 mm SCPE225 LS SC225 LS 250 mm SCP250 LS SC250 LS 280 mm SC280 LS 300 mm PVC300SC LS SCPE300 LS SC315 LS Galvanised iron threaded ends BSP female 2000 kPa Note 25mm can be supplied with straight pipe sections already fitted Part GAL25 T2 PVC T piece Class 18 Cat 19 Glue i...

Страница 9: ...4 ME3000 ME995 wiring with RPFS or other powered flowmeters ...

Страница 10: ...5 ME3000 ME995 wiring with RPFS or other powered flowmeters ...

Страница 11: ...6 PLUMBING INSTALL options guide for RPFS or other ManuFlo flowmeters ...

Страница 12: ...7 ...

Страница 13: ...blem Calcium buildup on wheel soak in diluted acid Warn bushes Backflow alarm Non return valve faulty jammed open Clean service or replace after batch complete Solenoid valve not properly closed damaged seal faulty solenoid Batch target display counter Flowrate too fast excessive overflow Turn down gate valve to restrict flowrate counts past batch selection or set preact overflow deduct function t...

Отзывы: