background image

 

Manu

Flo

 

 

 

 

 

       

Page 5

 

 

             

MANU ELECTRONICS

 

PTY LTD

 

Flow Measurement Products

                                                                                            

41 Carter Road, Brookvale NSW 2100 

                                        

                         

 

                                   

Website: 

http://www.manuelectronics.com.au

 

 

RPFS_Datasheet 23/02/2018

 

 

RPFS

 

ROTA PULSE FLOW SENSOR       

(Slip Insertion Paddlewheel) 

  

DATASHEET 

 

        

 

FEATURES 

 

 

± 2.5% accuracy @ velocity range 0.5 to 8.5 m/sec. 

 

± 1   % accuracy over linear range 0.7 to 7.0 m/sec. 

 

Repeatability of ±0.6%. 

 

 

NPN inductive pulse with internal amplification. 

 

Square wave output with short circuit protection.  

 

 

Inductive coil pulse option for low current applications.

 

 

 

High Pressure options to 2000kpa 

 

 

50

C or 120

C temperature models. 

 

 

Simple installation and maintenance. 

 

Large range of pipe adapter fittings in sizes 20 to 110mm. 

(Larger pipe sizes to 500mm using “Long Stem” –LS version) 

 

 

 

Stainless Steel 17-4PH paddlewheel rotor without magnets. 

 

 

Australian made since 1984. 

(Now with new high speed bush option).

 

 

DESCRIPTION 

The Rota Pulse Flow Sensor (RPFS) paddlewheel insertion type flowmeter uses a proven 
principle  of  flow  measurement,  which  is  used  worldwide.  The  RPFS  comes  in  four  model 
variants: 

 

RPFS-P

 for liquids up to   50

C (plug-in cable) 

 

RPFS-H

 for liquids up to 120

C  

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   RPFS-P 

 

All model variants insert directly into a large range of pipe adapter fittings available in PVC, Galvanized Iron, Brass, Stainless 
Steel or Polypipe materials, covering pipe sizes 20 to 110mm (standard sizes). This makes the RPFS suitable for a wide range of 
liquid flow measurement, monitoring and batching applications. Using the BSPB & BSPSS fittings adaption to larger size pipes is 
possible depending on pipe wall thickness, alternatively the Long Stem (-LS) versions with adaptors are then used. 

 

With only one moving part and limited intrusion into the pipe, and combined with its flow-through design, the RPFS allows 
accurate measurement of liquid flows with virtually no head losses. 

 

Each of the 4 blades of the rotor (paddlewheel) extends approximately one centimetre into the flowing liquid. The RPFS-P sensor 
generates a square wave pulse with the frequency output proportional to flow velocity and proportional to pipe diameter. The 
RPFS-P incorporates internal amplification, allowing pulse transmission up to 1000 metres to the receiver device. The RPFS-P 
model is specially constructed  with a metal shielding jacket making it immune to electrical interference.  

 

Magnets are not used in the RPFS models, thereby eliminating iron particles jamming the rotor. The alloy rotor used also makes 
the RPFS less susceptible to interference from turbulence and particles hitting the rotor, thereby giving superior flow results.

  

 

SPECIFICATIONS 

 

 

Model 

  RPFS-P 

RPFS-H 

 

Supply voltage 

5-30VDC 

5-30VDC 

 

Output signal 

NPN open collector 

NPN open collector 

 

 

50% duty cycle pulse 

50% duty cycle pulse 

 

Current draw @ 5VDC / 24VDC 

2.5mA / 10mA 

2.5mA / 10mA 

 

Max. switching current  

200 Ma (at 24VDC) 

200 mA  (at 24VDC) 

 

Cable length 

5 metres, plug-in cable  2 metres cable 

 

 

3-core (3 wire) 

2-core shielded (3 wire) 

 

Fluid temperature 

50 °C max. 

120 °C max. 

 

Weather rating 

IP67 

IP65 

 

Pressure rating 

200psi 

400psi 

 

Accuracy 

± 2.5% for 0.5 to 8.5 m/s, ±1% for 0.7 to 7.0 m/s, Repeatability ± 0.6% 

For Pipe Sizes 

15 to 110mm standard,  
Larger pipes via BSPB-LS special adaptor or saddle clamps. 

Содержание ManuFlo ME3000-RPFS

Страница 1: ...flowmeter as per the installation guide found on the flowmeter brochure Install the Rota Pulse paddlewheel sensor RPFS P in a straight pipe section with the same diameter pipe as the adaptor tee section with 10x diameter before and 5x diameter after the sensor with no elbows reducers valves or restrictions within this pipe run Where the sensor is housed the pipe must be full when measuring D Use s...

Страница 2: ...nd continuously if an error occurs With the ME3000 Batch Controller using the same instrument housing and the same 10 pin Weidmuller receptacle plug as other ManuFlo Batch Controller models changeover or upgrade is instant with no rewiring necessary It can be easily interfaced with PLCs through the optional computer control interface thus incorporating the controller s safety features and providin...

Страница 3: ...nfiguration value is diplayed entering a new value via the keypad causes the display value to change and flash Then pressing SET locks in the new value or pressing CANCEL reverts value to its original setting and the display digits stop flashing Use the up down arrows buttons to step through more configuration settings or press CANCEL for 2 seconds to exit to the SET RDY display CALIBRATION 1 The ...

Страница 4: ...nel Eagle etc PLCs MC 4 pin PLC Computer Command Start Stop Reset interface plug MC2 2 pin plug for scaled open collector pulse output Includes 4 pin external command Start Stop Reset interface plug e g ME3000 is the standard Batch Controller 240vac powered without any of the options whereas ME3000 MC2 is an ME3000 Batch Controller with a scaled open collector pulse o p and external Start Stop Res...

Страница 5: ...tion to larger size pipes is possible depending on pipe wall thickness alternatively the Long Stem LS versions with adaptors are then used With only one moving part and limited intrusion into the pipe and combined with its flow through design the RPFS allows accurate measurement of liquid flows with virtually no head losses Each of the 4 blades of the rotor paddlewheel extends approximately one ce...

Страница 6: ...G 6 1 Unscrew the black PVC locking cap anti clockwise 2 Hold the neck of the Tee piece in your left hand grasp the RPFS body with your right hand and turn slowly anti clockwise until the sensor hydraulically raises out of slot then pull upwards out of the socket never by the cable When returning the sensor to nipple adaptor insert so the keyway and slots line up then then push down until they loc...

Страница 7: ...e If mounted in horizontal or inclined pipe make sure insertion position of sensor is at top or 45 from top not on the underside Selection of pipe diameter For best results use the table below Pipe size Flowrange Litres min Pulses Litre mm Min Max approx 1 2 20 13 160 116 25 20 250 75 32 30 410 46 40 50 640 30 50 90 1000 20 63 132 1580 11 7 65 120 1690 12 75 180 2250 8 3 80 190 2560 7 3 90 244 324...

Страница 8: ...25 LS 140 mm SC140 LS 150 mm PVC150SC LS SCP150 LS SC160 LS 160 mm SCPE160 LS SC160 LS 200 mm PVC200SC LS SCP200 LS SC200 LS 225 mm SCPE225 LS SC225 LS 250 mm SCP250 LS SC250 LS 280 mm SC280 LS 300 mm PVC300SC LS SCPE300 LS SC315 LS Galvanised iron threaded ends BSP female 2000 kPa Note 25mm can be supplied with straight pipe sections already fitted Part GAL25 T2 PVC T piece Class 18 Cat 19 Glue i...

Страница 9: ...4 ME3000 ME995 wiring with RPFS or other powered flowmeters ...

Страница 10: ...5 ME3000 ME995 wiring with RPFS or other powered flowmeters ...

Страница 11: ...6 PLUMBING INSTALL options guide for RPFS or other ManuFlo flowmeters ...

Страница 12: ...7 ...

Страница 13: ...blem Calcium buildup on wheel soak in diluted acid Warn bushes Backflow alarm Non return valve faulty jammed open Clean service or replace after batch complete Solenoid valve not properly closed damaged seal faulty solenoid Batch target display counter Flowrate too fast excessive overflow Turn down gate valve to restrict flowrate counts past batch selection or set preact overflow deduct function t...