OPERATING INSTRUCTIONS
ME3000
Switch the power ON to unit. In a few seconds, the display shows SET and RDY(ready), with a zero quantity for RDY, all LED
indicators and alarms are off. The unit is ready for batching or configuration.
BATCHING: When SET/RDY is displayed, entering a batch quantity via the numeric keypad buttons will cause the displayed SET
value to change and flash. Then, pressing the SET button locks in the new value, or pressing CANCEL reverts the value to its
original setting, and the display digits stop flashing.
Press the START BATCH button to start batch batching the set quantity. The RDY line title changes to REC (received).
The voltage contact drive activates, the RUN LED illuminates indicating pump or solenoid are energized, followed by FLOW LED
illuminating, indicating pulsing and operation of flowmeter. The digits on the REC (received) display line begin counting upward
towards the selected batch quantity.
Upon REC digits reaching the selected batch quantity the alarm sounds (short beep) indicating completion of batch; RUN, FLOW
and OUTPUT LEDs turn off. The displayed SET and REC values should correspond. If REC digits overshoot target, then scale back
the difference by changing the Preact value via the Configuration Mode (see below).
To interrupt batch, push STOP button; REC counting will stop, and drive contact goes off. Push START BATCH to resume batch.
On batch completion or termination, press RESET. Display REC line title changes to RDY (ready).
To dispense the same set quantity again, press START BATCH. Otherwise, use the keypad to enter a new batch quantity.
Warning: if RUN or FLOW LED indicators are on, but controller is not counting, discontinue use and call for service.
EVENT LOG: using a straight-through female- to-female DB9 cable, connect from the Batch Controller’s (optional) RS232 port to a
Laptop/PC serial port. On the Laptop, start the HyperTerminal software (supplied as part of Windows), set up a connection at 9600
baud, 8 Data Bits, no parity, 1 stop bit, and capture text to a file. On the Controller, press the CANCEL and RESET buttons (those
marked with ‘#’) simultaneously for 5 secs, and the Event Log will download. To stop download, press CANCEL for 2 secs.
CONFIGURATION: The Controller is factory configured to your requirements, but can be re-programmed by the user if required.
Configuration Mode is entered from the SET/RDY display by pressing the CANCEL and STOP buttons (those marked with a ‘*’)
simultaneously for 5 seconds.
Use the buttons with the up/down arrows to step through configuration settings.
When a configuration value is diplayed, entering a new value via the keypad causes the display value to change and flash. Then,
pressing SET locks in the new value, or pressing CANCEL reverts value to its original setting, and the display digits stop flashing.
Use the up/down arrows buttons to step through more configuration settings, or press CANCEL for 2 seconds to exit to the
SET/RDY display.
CALIBRATION
1) The Batch Controller is set up for the connected flowmeter using the Calibration Input pulse scaling item under Configuration Mode,
to match the flowmeter’s output pulse value.
On-site calibration adjustment and test:
2) Must adjust what is shown as received (REC) on the Batch Controller LCD display to match a known amount dispensed. So, set
batch quantity to say 190L, and batch into a 200 litre (44 gallon) drum.
3) If the amount collected is
more
than the REC amount shown on the LCD display, then
decrease
the
Calibration Input
value
by the same % difference e.g. if collected 200L when 190L on LCD, this is 10L more or 5% over (10/190x100%).
So, decrease the calibration value by 5% i.e. if Calibration Input value is 300, new value is 300-5% = 300-15 = 285.
4) If the amount collected is
less
than the REC amount shown
on the LCD display, then
increase the Calibration Input value
by the
same % difference. e.g. if collected 180L when 190L on LCD, this is 10L less or 5% under (10/190x100%).
So, increase the calibration value by 5% i.e. if Calibration Input value is 300, new value is 300+5% = 300+15 = 315.
5)
PREACT:
To
calibrate inflight overflow, enter Configuration Mode (as described above), and set the Preact value to the same
overflow reading as indicated by the LCD display, where overflow = (the REC quantity) - (the SET quantity).
Example: You set 190 Litres, batch the quantity, 200 Litres is shown on display, and 200 Litres is collected in drum. A valve may take
extra time to close, so the received quantity usually overshoots. So, set 10 Litres on Preact to deduct the 10 Litres overshoot. Next
batch, the set batch quantity, LCD REC reading and amount collected in drum are all 190 Litres.
SPECIFICATIONS
shown with optional
-SC and -5P interfaces
Power supply
220-250 vac (optional 110 vac or 12-24 VDC)
Fuse
1 Amp (5 x 20mm case)
Frequency input
5 KHz
Event Log
internally records up to 300 batches
Output to flowmeter
12 VDC upto 100mA
Relay
Max. 240 vac, 1 A. Open Contact on request.
Display
2 line x 16 character, for quantity set and dispensed.
Connection
10 pin Weidmuller mating plug and socket
Batch entry
quantity selection and commands via IP64 keypad
Optional Outputs
scaled pulse output; 4-20mA output
Optional interfaces
RS232; PLC/Computer stop/start/reset
Instrument housing
ABS hi-impact case mould
Mounting
Panel mount. Panel cutout :190 L, 122 H mm
External dimensions
206 L, 130 H, 90 D mm.
Weight
1 kg
Due to continuous product improvement, specifications are subject to change without notice.